@inproceedings{PascualHeinkeEchleetal.2020, author = {Domenic Pascual and Matthias Heinke and Reinhard Echle and Johannes H{\"o}rth}, title = {Electrode Model and Simulation of His Bundle Pacing for Cardiac Resynchronization Therapy}, series = {Biomedical Engineering / Biomedizinische Technik}, volume = {65}, number = {s1}, publisher = {Walter de Gruyter}, address = {Berlin, Boston}, organization = {Joint Journal of the German Society for Biomedical Engineering in VDE and the Austrian and Swiss Societies for Biomedical Engineering and the German Society of Biomaterials}, issn = {1862-278X (Online)}, doi = {10.1515/bmt-2020-6044}, pages = {258}, year = {2020}, abstract = {Background: A disturbed synchronization of the ventricular contraction can cause a highly developed systolic heart failure in affected patients, which can often be explained by a diseased left bundle branch block (LBBB). If medication remains unresponsive, the concerned patients will be treated with a cardiac resynchronization therapy (CRT) system. The aim of this study was to integrate His bundle pacing into the Offenburg heart rhythm model in order to visualize the electrical pacing field generated by His bundle pacing. Methods: Modelling and electrical field simulation activities were performed with the software CST (Computer Simulation Technology) from Dessault Syst{\`e}ms. CRT with biventricular pacing is to be achieved by an apical right ventricular electrode and an additional left ventricular electrode, which is floated into the coronary vein sinus. This conventional type of biventricular pacing leads to a reduction of the left ventricular ejection fraction. Furthermore, the non-responder rate of the CRT therapy is about one third of the CRT patients. Results: His bundle pacing represents a physiological alternative to conventional cardiac pacing and cardiac resynchronization. An electrode implanted in the His bundle emits a stronger electrical pacing field than the electrical pacing field of conventional cardiac pacemakers. The pacing of the His bundle was performed by the Medtronic Select Secure 3830 electrode with pacing voltage amplitudes of 3 V, 2 V and 1.5 V in combination with a pacing pulse duration of 1 ms. Conclusions: Compared to conventional cardiac pacemaker pacing, His bundle pacing is capable of bridging LBBB conduction disorders in the left ventricle. The His bundle pacing electrical field is able to spread via the physiological pathway in the right and left ventricles for CRT with a narrow QRS-complex in the surface ECG.}, language = {en} }