Isothermal and thermomechanical low-cycle fatigue of the hot work steel X38CrMoV5-3 with and without overaging heat treatment

  • In this work, the martensitic hot work steel X38CrMoV5-3 is investigated by isothermal and thermomechanical fatigue tests conducted between 20 and 650 °C with mechanical strain amplitudes from 0.4 to 1%. The fatigue behavior of the material hardened and tempered to 54 HRC is compared to conditions subjected to different overaging heat treatments, resulting in reduced hardness levels. Time- andIn this work, the martensitic hot work steel X38CrMoV5-3 is investigated by isothermal and thermomechanical fatigue tests conducted between 20 and 650 °C with mechanical strain amplitudes from 0.4 to 1%. The fatigue behavior of the material hardened and tempered to 54 HRC is compared to conditions subjected to different overaging heat treatments, resulting in reduced hardness levels. Time- and temperature-dependent deformation including thermal and cyclic softening as well as stress relaxation and rate-dependent effects are analyzed with pronounced changes above 500 °C depending on heat treatment. Overaging affects fatigue life positively or negatively, depending on temperature and strain amplitude. At lower temperatures, materials with high hardness tend to exhibit partially brittle fracture surfaces, while at high temperatures a creep-enhanced low-deformation ductile fracture and oxidation is observed. In-phase thermomechanical fatigue conditions are more detrimental than out-of-phase TMF conditions. Classical fatigue damage parameters are not capable of adequately capturing the effects of temperature, phase relationship and heat treatment on fatigue life.…zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Statistik

frontdoor_oas
Metadaten
Dokumentart:Zeitschriftenartikel, wissenschaftlich
Review-Status:Begutachtet (reviewed)
Zitierlink: https://opus.hs-offenburg.de/11505
Bibliografische Angaben
Titel (Englisch):Isothermal and thermomechanical low-cycle fatigue of the hot work steel X38CrMoV5-3 with and without overaging heat treatment
Verfasserangaben:Markus SchlayerStaff MemberORCiD, Marc Warwas, Karin Hintz, Dietmar KohlerStaff MemberGND, Thomas SeifertStaff MemberORCiDGND
Erscheinungsjahr:2026
Datum der Erstveröffentlichung:29.10.2025
Verlag:Elsevier
Erste Seite:1
Letzte Seite:20
Aufsatznummer:109353
Titel des übergeordneten Werkes (Englisch):International Journal of Fatigue
Jahrgang (Band):203
ISSN:1879-3452 (Online)
ISSN:0142-1123 (Print)
DOI:https://doi.org/10.1016/j.ijfatigue.2025.109353
URN:https://urn:nbn:de:bsz:ofb1-opus4-115055
Sprache:Englisch
Inhaltliche Informationen
Fakultäten / Einrichtungen:Fakultät Maschinenbau und Verfahrenstechnik (M+V)
Forschung:IDEeP - Institute for Digital Engineering and Production (ab 12.10.2022)
Sammlungen der Hochschule Offenburg:Bibliografie
DDC-Sachgruppen:600 Technik, Medizin, angewandte Wissenschaften
Freies Schlagwort / Tag:Heat treatment; Hot work steel; Low-cycle fatigue; Overaging; Softening; Thermomechanical fatigue
Gefördert durch (Auswahl):Deutsche Forschungsgemeinschaft
Gefördert durch (Freitext):Hochschule Offenburg
Projektnummer:244928365
Speicherung von Forschungsdaten:Fachliches Repositorium
URL zu den Forschungsdaten:https://doi.org/10.5281/zenodo.15768757
Formale Angaben
Relevanz für "Jahresbericht über Forschungsleistungen":5-fach | Wiss. Zeitschriftenartikel reviewed: AGQ-Positivlisten
Open-Access-Status: Open Access 
 Hybrid 
Lizenz (Deutsch):License LogoCreative Commons - CC BY - Namensnennung 4.0 International