Climate-adaptive hygrothermal optimization of heavy cob walls based on thickness sensitivity analysis and TOPSIS method
- Moisture resilience is essential for earthen buildings, as their durability depends on moisture regulation under dynamic conditions. While their hygrothermal behavior remains sensitive to climatic conditions and wall thickness, the latter is typically designed from a thermal perspective rather than optimized through coupled heat–moisture approaches supported by experimental characterization. ThisMoisture resilience is essential for earthen buildings, as their durability depends on moisture regulation under dynamic conditions. While their hygrothermal behavior remains sensitive to climatic conditions and wall thickness, the latter is typically designed from a thermal perspective rather than optimized through coupled heat–moisture approaches supported by experimental characterization. This study proposes an integrated optimization framework to evaluate climate-adapted thicknesses for the investigated heavy cob walls. A comprehensive experimental characterization was conducted to determine the thermo-hygric properties, including thermal conductivity, porosity, vapor diffusion resistance, capillary absorption, and moisture buffering capacity. These properties were implemented in transient hygrothermal simulations to analyze surface temperature, relative humidity, and moisture dynamics for wall thicknesses ranging from 20 to 40 cm across six representative Moroccan climate zones. The simulation outputs were assessed against hygrothermal comfort and moisture-related performance criteria and integrated into a multi-criteria decision framework using the TOPSIS method, supported by a Thickness Sensitivity Index (TSI). The results indicate that increasing thickness improves thermal inertia, increases minimum internal surface temperatures, and reduces moisture excesses, even if relative humidity frequently exceeds 60%. Within the assumptions of the adopted material formulation, simulation framework, and decision methodology, the comparative assessment identified 40 cm as the most suitable thickness for the moisture-sensitive climates (CZ1, CZ2, CZ5), whereas 35 cm provided comparable overall performance in the thermally dominated climates (CZ3, CZ4, CZ6). These findings highlight the importance of climate-specific hygrothermal assessment for thickness selection while acknowledging that structural requirements and alternative wall configurations should be considered in design.…


| Dokumentart: | Zeitschriftenartikel, wissenschaftlich |
|---|---|
| Review-Status: | Begutachtet (reviewed) |
| Zitierlink: | https://opus.hs-offenburg.de/13282 | Bibliografische Angaben |
| Titel (Englisch): | Climate-adaptive hygrothermal optimization of heavy cob walls based on thickness sensitivity analysis and TOPSIS method |
| Verfasserangaben: | Yamna Soussi, Mouatassim CharaiORCiD, Said Oubaha, Mohamed Oualid Mghazli, Jens PfafferottStaff MemberORCiDGND, Fatima-Ezzahra El Abbassi |
| Erscheinungsjahr: | 2026 |
| Datum der Erstveröffentlichung: | 19.08.2026 |
| Verlagsort: | Amsterdam |
| Verlag: | Elsevier |
| Seitenanzahl: | 18 |
| Erste Seite: | 1 |
| Letzte Seite: | 18 |
| Aufsatznummer: | 112541 |
| Titel des übergeordneten Werkes (Englisch): | Results in Engineering |
| Jahrgang (Band): | 32 |
| Heft (Ausgabe): | December 2026 |
| ISSN: | 2590-1230 |
| DOI: | https://doi.org/10.1016/j.rineng.2026.112541 |
| Sprache: | Englisch | Inhaltliche Informationen |
| Fakultäten / Einrichtungen: | Fakultät Maschinenbau und Verfahrenstechnik (M+V) |
| Forschung: | INES - Institut für nachhaltige Energiesysteme |
| Sammlungen der Hochschule Offenburg: | Bibliografie |
| Projekte / village.school | |
| DDC-Sachgruppen: | 600 Technik, Medizin, angewandte Wissenschaften |
| Freies Schlagwort / Tag: | climate; cob walls; hygrothermal performance; optimization and sensitivity analysis; sustainable construction |
| Projektnummer: | 950102157 | Formale Angaben |
| Relevanz für "Jahresbericht über Forschungsleistungen": | 5-fach | Wiss. Zeitschriftenartikel reviewed: AGQ-Zeitschriftenliste |
| Open-Access-Status: | Open Access |
| Gold | |
| Lizenz (Deutsch): | Creative Commons - CC BY-NC - Namensnennung - Nicht kommerziell 4.0 International |



