Volltext-Downloads (blau) und Frontdoor-Views (grau)

The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users

  • Objective: The present study evaluated whether the poorer baseline performance of cochlear implant (CI) users or the technical and/or physiological properties of CI stimulation are responsible for the absence of masking release. Design: This study measured speech reception thresholds (SRTs) in continuous and modulated noise as a function of signal to noise ratio (SNR). Study sample: A total of 24Objective: The present study evaluated whether the poorer baseline performance of cochlear implant (CI) users or the technical and/or physiological properties of CI stimulation are responsible for the absence of masking release. Design: This study measured speech reception thresholds (SRTs) in continuous and modulated noise as a function of signal to noise ratio (SNR). Study sample: A total of 24 subjects participated: 12 normal-hearing (NH) listeners and 12 subjects provided with recent MED-EL CI systems. Results: The mean SRT of CI users in continuous noise was −3.0 ± 1.5 dB SNR (mean ± SEM), while the normal-hearing group reached −5.9 ± 0.8 dB SNR. In modulated noise, the difference across groups increased considerably. For CI users, the mean SRT worsened to −1.4 ± 2.3 dB SNR, while it improved for normal-hearing listeners to −18.9 ± 3.8 dB SNR. Conclusions: The detrimental effect of fluctuating maskers on SRTs in CI users shown by prior studies was confirmed by the current study. Concluding, the absence of masking release is mainly caused by the technical and/or physiological properties of CI stimulation, not just the poorer baseline performance of many CI users compared to normal-hearing subjects. Speech understanding in modulated noise was more robust in CI users who had a relatively large electrical dynamic range.…zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar

Statistik

frontdoor_oas
Metadaten
Dokumentart:Zeitschriftenartikel, wissenschaftlich
Review-Status:Begutachtet (reviewed)
Zitierlink: https://opus.hs-offenburg.de/2252
Bibliografische Angaben
Titel (Englisch):The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users
Verfasserangaben:Stefan ZirnStaff MemberORCiDGND, Daniel Polterauer, Stefanie Keller, Werner HemmertORCiD
Erscheinungsjahr:2016
Datum der Erstveröffentlichung:10.02.2016
Erste Seite:295
Letzte Seite:304
Titel des übergeordneten Werkes (Englisch):International Journal of Audiology
Jahrgang (Band):55
Heft (Ausgabe):5
DOI:https://doi.org/10.3109/14992027.2015.1128124
URL:http://www.tandfonline.com/doi/abs/10.3109/1499202710.3109/14992027.2015.1128124
Sprache:Englisch
Inhaltliche Informationen
Fakultäten / Einrichtungen:Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019)
Sammlungen der Hochschule Offenburg:Bibliografie
Freies Schlagwort / Tag:Cochlea; Implantat; Sprache; Verstehen
Formale Angaben
Open-Access-Status: Closed Access 
Lizenz (Deutsch):License LogoUrheberrechtlich geschützt