Volltext-Downloads (blau) und Frontdoor-Views (grau)

Numerical Analysis of the Building Energy Efficiency Using Two Different HVAC Systems: Variable Refrigerant Flow and Variable Air Volume Technologies

  • Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, atVariable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.…zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar

Statistik

frontdoor_oas
Metadaten
Dokumentart:Konferenzveröffentlichung
Art der Konferenzveröffentlichung:Konferenzartikel
Zitierlink: https://opus.hs-offenburg.de/8434
Bibliografische Angaben
Titel (Englisch):Numerical Analysis of the Building Energy Efficiency Using Two Different HVAC Systems: Variable Refrigerant Flow and Variable Air Volume Technologies
Konferenzangaben:International Congress on Materials and Structural Stability (4. : March 6-10, 2023 : Rabat, Morocco)
Verfasserangaben:Niima Es-sakaliORCiD, Samir Idrissi Kaitouni, Mohamed Oualid Mghazli, Moha Cherkaoui, Jens PfafferottStaff MemberORCiDGND
Erscheinungsjahr:2023
Erste Seite:S389
Letzte Seite:S395
Titel des übergeordneten Werkes (Englisch):NanoWorld Journal
Jahrgang (Band):9
Heft (Ausgabe):S2
ISSN:2379-1101
DOI:https://doi.org/10.17756/nwj.2023-s2-066
URN:https://urn:nbn:de:bsz:ofb1-opus4-84343
Sprache:Englisch
Inhaltliche Informationen
Fakultäten / Einrichtungen:Fakultät Maschinenbau und Verfahrenstechnik (M+V)
Forschung:INES - Institut für nachhaltige Energiesysteme
Sammlungen der Hochschule Offenburg:Bibliografie
Formale Angaben
Relevanz für "Jahresbericht über Forschungsleistungen":1-fach | Konferenzbeitrag
Open-Access-Status: Open Access 
 Gold 
Lizenz (Deutsch):License LogoCreative Commons - CC BY - Namensnennung 4.0 International