Esophageal electrode model and simulation of directed transesophageal electrical pacing of the spinal cord

  • Spinal cord stimulation (SCS) is the most commonly used technique of neurostimulation. It involves the stimulation of the spinal cord and is therefore used to treat chronic pain. The existing esophageal catheters are used for temperature monitoring during an electrophysiology study with ablation and transesophageal echocardiography. The aim of the study was to model the spine and new esophagealSpinal cord stimulation (SCS) is the most commonly used technique of neurostimulation. It involves the stimulation of the spinal cord and is therefore used to treat chronic pain. The existing esophageal catheters are used for temperature monitoring during an electrophysiology study with ablation and transesophageal echocardiography. The aim of the study was to model the spine and new esophageal electrodes for the transesophageal electrical pacing of the spinal cord, and to integrate them in the Offenburg heart rhythm model for the static and dynamic simulation of transesophageal neurostimulation. The modeling and simulation were both performed with the electromagnetic and thermal simulation software CST (Computer Simulation Technology, Darmstadt). Two new esophageal catheters were modelled as well as a thoracic spine based on the dimensions of a human skeleton. The simulation of directed transesophageal neurostimulation is performed using the esophageal balloon catheter with an electric pacing potential of 5 V and a trapezoidal signal. A potential of 4.33 V can be measured directly at the electrode, 3.71 V in the myocardium at a depth of 2 mm, 2.68 V in the thoracic vertebra at a depth of 10 mm, 2.1 V in the thoracic vertebra at a depth of 50 mm and 2.09 V in the spinal cord at a depth of 70 mm. The relation between the voltage delivered to the electrodes and the voltage applied to the spinal cord is linear. Virtual heart rhythm and catheter models as well as the simulation of electrical pacing fields and electrical sensing fields allow the static and dynamic simulation of directed transesophageal electrical pacing of the spinal cord. The 3D simulation of the electrical sensing and pacing fields may be used to optimize transesophageal neurostimulation.show moreshow less

Export metadata

Statistics

frontdoor_oas
Metadaten
Document Type:Conference Proceeding
Conference Type:Konferenz-Abstract
Zitierlink: https://opus.hs-offenburg.de/3730
Bibliografische Angaben
Title (English):Esophageal electrode model and simulation of directed transesophageal electrical pacing of the spinal cord
Conference:BMT 2019: Annual Conference of the German Society for Biomedical Engineering / DGBMT Jahrestagung (53. : 25.-26. September 2019 : Frankfurt am Main, Deutschland)
Author:Manuela Schleh, Matthias HeinkeStaff MemberORCiDGND, Johannes HörthStaff MemberGND
Year of Publication:2019
Place of publication:Berlin, Boston
Publisher:Walter de Gruyter
Page Number:1
First Page:54
Parent Title (English):Biomedical Engineering / Biomedizinische Technik
Volume:64
Issue:s2
ISSN:1862-278X (Online)
ISSN:0013-5585 (Print)
DOI:https://doi.org/10.1515/bmt-2019-6011
Language:English
Inhaltliche Informationen
Institutes:Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019)
Institutes:Bibliografie
Tag:Bioimpedance measurement; Esophageal catheter; Heart rhythm model; Modeling and simulation; Spinal cord stimulation