A Multi-Criteria Assessment Strategy for 3D Printed Porous Polyetheretherketone (PEEK) Patient-Specific Implants for Orbital Wall Reconstruction

  • Pure orbital blowout fractures occur within the confines of the internal orbital wall. Restoration of orbital form and volume is paramount to prevent functional and esthetic impairment. The anatomical peculiarity of the orbit has encouraged surgeons to develop implants with customized features to restore its architecture. This has resulted in worldwide clinical demand for patient-specific implantsPure orbital blowout fractures occur within the confines of the internal orbital wall. Restoration of orbital form and volume is paramount to prevent functional and esthetic impairment. The anatomical peculiarity of the orbit has encouraged surgeons to develop implants with customized features to restore its architecture. This has resulted in worldwide clinical demand for patient-specific implants (PSIs) designed to fit precisely in the patient’s unique anatomy. Material extrusion or Fused filament fabrication (FFF) three-dimensional (3D) printing technology has enabled the fabrication of implant-grade polymers such as Polyetheretherketone (PEEK), paving the way for a more sophisticated generation of biomaterials. This study evaluates the FFF 3D printed PEEK orbital mesh customized implants with a metric considering the relevant design, biomechanical, and morphological parameters. The performance of the implants is studied as a function of varying thicknesses and porous design constructs through a finite element (FE) based computational model and a decision matrix based statistical approach. The maximum stress values achieved in our results predict the high durability of the implants, and the maximum deformation values were under one-tenth of a millimeter (mm) domain in all the implant profile configurations. The circular patterned implant (0.9 mm) had the best performance score. The study demonstrates that compounding multi-design computational analysis with 3D printing can be beneficial for the optimal restoration of the orbital floor.show moreshow less

Download full text files

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Document Type:Article (reviewed)
Zitierlink: https://opus.hs-offenburg.de/5045
Bibliografische Angaben
Title (English):A Multi-Criteria Assessment Strategy for 3D Printed Porous Polyetheretherketone (PEEK) Patient-Specific Implants for Orbital Wall Reconstruction
Author:Neha Sharma, Dennis Welker, Soheila Aghlmandi, Michaela Maintz, Hans-Florian Zeilhofer, Thomas SeifertStaff MemberORCiDGND, Philipp Honigmann, Florian M. Thieringer
Year of Publication:2021
Date of first Publication:2021/08/13
Place of publication:Basel
Publisher:MDPI
Page Number:17
First Page:1
Last Page:17
Article Number:3563
Parent Title (English):Journal of Clinical Medicine
Volume:10
Issue:16
ISSN:2077-0383
DOI:https://doi.org/10.3390/jcm10163563
URN:https://urn:nbn:de:bsz:ofb1-opus4-50451
Language:English
Inhaltliche Informationen
Institutes:Fakultät Maschinenbau und Verfahrenstechnik (M+V)
Institutes:Bibliografie
Tag:biocompatible materials; blow-out; computer-aided design; finite element analysis; implant; orbit; orbital fracture; patient-specific modeling; printing; three-dimensional
Formale Angaben
Open Access: Open Access 
Licence (German):License LogoCreative Commons - CC BY - Namensnennung 4.0 International