Characterization of interventricular desynchronization in heart failure patients
- Currently, QRS width and bundle branch block morphology are used as electrocardiographic guideline criterias to selectheart failure (HF) patients with interventricular desynchronization in sinus rhythm (SR) for cardiac resynchronisationtherapy (CRT). Nevertheless, up to 30% of these patients do not benefit from implantation of CRT systems. Esophagealleft ventricular electrogram (LVE) enablesCurrently, QRS width and bundle branch block morphology are used as electrocardiographic guideline criterias to selectheart failure (HF) patients with interventricular desynchronization in sinus rhythm (SR) for cardiac resynchronisationtherapy (CRT). Nevertheless, up to 30% of these patients do not benefit from implantation of CRT systems. Esophagealleft ventricular electrogram (LVE) enables semi-invasive measurement of interventricular conduction delays (IVCD)even in patients with atrial fibrillation (AF). To routinely apply this method, a programmer based semi-invasiveautomatic quantification of IVCD should to be developed. Our aims were todefine interventricular conduction delaysby analyzing fractionated left ventricular (LV) deflections in the esophageal left ventricular electrogram of HF patientsin SR or AF. In 66 HF patients (49 male,17 female, age 65 ± 10 years) a 5F TOslim electrode (Osypka AG, Germany) was perorallyapplied. Using BARD EP Lab, cardiac desynchronization was quantified as interval IVCD between onset of QRS insurface ECG and the investigator-determined onset of the left ventricular deflection in LVE. IVCD was compared withthe intervals between QRS onset and the first maximum (IVCDm1) and between QRS onset and the second maximum(IVCDm2) of the LV complex. QRS of 173 ± 26 ms was linked with empirical IVCD of 75 ± 25 ms, at mean. First and second LV maximum could beascertained beyond doubt in all patients. Significant correlations of the p<0,01 level were found between IVCD and theIVCDm1 of 96 ± 28 ms as well as between IVCD and the IVCDm2 of 147 ± 31 ms, at mean. To standardize automatic measurement of interventricular conduction delays with respect to patients with fractionatedLV complexes, the first maximum of the LV deflection should be utilized to qualify the IVCD of HF patients with sinusrhythm and atrial fibrillation.…
Document Type: | Conference Proceeding |
---|---|
Conference Type: | Konferenzartikel |
Zitierlink: | https://opus.hs-offenburg.de/827 | Bibliografische Angaben |
Title (English): | Characterization of interventricular desynchronization in heart failure patients |
Conference: | BMT 2012: Annual Conference of the German Society for Biomedical Engineering / DGBMT Jahrestagung (45. : 16.-19. September 2012 : Jena) |
Author: | Kirsten-Maria Rotter, Katharina Kroll, Christoph A. Nienaber, Bruno IsmerStaff MemberGND |
Date of Publication (online): | 2012/09/06 |
Place of publication: | Berlin, Boston |
Publisher: | Walter de Gruyter |
First Page: | 837 |
Last Page: | 840 |
Parent Title (Multiple languages): | Biomedical Engineering / Biomedizinische Technik |
Editor: | Olaf Dössel |
Volume: | 57 |
Issue: | SI-1-Track-Q |
ISSN: | 0013-5585 (Print) |
ISSN: | 1862-278X (Online) |
DOI: | https://doi.org/10.1515/bmt-2012-4091 |
Language: | English | Inhaltliche Informationen |
Institutes: | Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) |
Institutes: | Bibliografie | Formale Angaben |
Open Access: | Open Access |
Licence (German): | Urheberrechtlich geschützt |