Electromagnetic and thermal simulation of supraventricular tachycardia catheter ablation

  • Background: The application of high-frequency ablation is used for the treatment of tachycardia arrhythmias and is a respected method. Ablation with high frequency current leads to the targeted heat destruction of myocardial tissue at specific sites and thus prevents the pathological propagation of excitation through these structures. Purpose: The aim of this study was to simulate heatBackground: The application of high-frequency ablation is used for the treatment of tachycardia arrhythmias and is a respected method. Ablation with high frequency current leads to the targeted heat destruction of myocardial tissue at specific sites and thus prevents the pathological propagation of excitation through these structures. Purpose: The aim of this study was to simulate heat propagation during RF ablation with modeled electrodes in different sizes and materials. The simulation was performed on atrioventricular node re-entry tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT) and atrial flutter (AFL). Methods: Using the modeling and simulation software CST, ablation catheters with 4 mm and 8 mm tip electrodes were modeled from gold and platinum for each. The designed catheters correspond to the manufacturer"s specifications of Medtronic, Biotronik and Osypka. The catheters were integrated into the Offenburg heart rhythm model to simulate and compare the heat propagation during an ablation application, which also takes into account the blood flow in the four heart chambers. A power of 5 W - 40 W was simulated for the 4 mm electrodes and a power of 50 W - 80 W for the 8 mm electrodes. Results: During the simulated HF ablation application, the temperature at the ablation electrode was measured at different powers. This is 40.67°C at 5 W, 44.34°C at 10 W, 51.76°C at 20 W, 59.0°C at 30 W, and 66.33°C at 40 W. The measured temperature during 40 W application is 39.5°C at 0,5 mm depth in the myocardium and 37.5°C at 2 mm depth. In the simulation, the 8 mm platinum electrode reached an ablation temperature of 72.85°C at its tip during an applied power of 60 W. In contrast, the 8 mm platinum electrode reached a depth of 5 mm at 39.5 C° and at a depth of 2 mm at 37.5 °C. In contrast, the 8 mm gold electrode reached a temperature of 64.66°C with the same performance. This is due to the thermal properties of gold, which has a better thermal conductivity than platinum. Conclusions: CST offers the possibility to carry out a static and dynamic simulation of a heart model and the ablation electrodes integrated in it during an HF ablation. In variation with different electrode sizes and materials, therapy methods for the treatment of AVNRT, AVRT and AFL can be optimizedshow moreshow less

Export metadata

Statistics

frontdoor_oas
Metadaten
Document Type:Conference Proceeding
Conference Type:Konferenz-Abstract
Zitierlink: https://opus.hs-offenburg.de/3632
Bibliografische Angaben
Title (English):Electromagnetic and thermal simulation of supraventricular tachycardia catheter ablation
Conference:EHRA 2019, March 17-19, 2019, Lisbon, Portugal
Author:Karl Ehret, Matthias HeinkeStaff MemberORCiDGND, Johannes HörthStaff MemberGND, Lukas Schilling
Year of Publication:2019
Creating Corporation:European Society of Cardiology
Page Number:1
First Page:ii159
Article Number:Abstract P478
Parent Title (English):EP Europace
Volume:21
Issue:Suppl. 2
ISSN:1099-5129
DOI:https://doi.org/10.1093/europace/euz093
Language:English
Inhaltliche Informationen
Institutes:Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019)
Institutes:Bibliografie
Tag:Electromagnetic and thermal simulation; Heart rhythm model; High frequency ablation; Modeling and simulation; Supraventricular tachycardia
Formale Angaben
Open Access: Closed Access 
Licence (German):License LogoUrheberrechtlich geschützt