Electrical Right and Left Cardiac Atrioventricular and Left Atrial Delay in Cardiac Resynchronization Therapy Responder and Non-responder with Sinus Rhythm

  • Cardiac resynchronization therapy (CRT) with hemodynamic optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and wide QRS complex. The aim of the study was to evaluate electrical right and left cardiac atrioventricular delay and left atrial delay in CRT responder and non-responder with sinus rhythm.Cardiac resynchronization therapy (CRT) with hemodynamic optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and wide QRS complex. The aim of the study was to evaluate electrical right and left cardiac atrioventricular delay and left atrial delay in CRT responder and non-responder with sinus rhythm. Methods: Heart failure patients with New York Heart Association class 3.0 ± 0.3, sinus rhythm and 27.7 ± 6.1% left ventricular ejection fraction were measured by surface ECG and transesophageal bipolar left atrial and left ventricular ECG before implantation of CRT devices. Electrical right cardiac atrioventricular delay was measured between onset of P wave and onset of QRS complex in the surface ECG, left cardiac atrioventricular delay between onset of left atrial signal and onset of left ventricular signal in the transesophageal ECG and left atrial delay between onset and offset of left atrial signal in the transesophageal ECG. Results: Electrical atrioventricular and left atrial delay were 196.9 ± 38.7 ms right and 194.5 ± 44.9 ms left cardiac atrioventricular delay, and 47.7 ± 13.9 ms left atrial delay. There were positive correlation between right and left cardiac atrioventricular delay (r = 0.803 P < 0.001) and negative correlation between left atrial delay and left ventricular ejection fraction (r = −0.694 P = 0.026) with 67% CRT responder. Conclusions: Transesophageal electrical left cardiac atrioventricular delay and left atrial delay may be useful preoperative atrial desynchronization parameters to improve CRT optimization.show moreshow less

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Document Type:Conference Proceeding
Conference Type:Konferenzartikel
Zitierlink: https://opus.hs-offenburg.de/3053
Bibliografische Angaben
Title (English):Electrical Right and Left Cardiac Atrioventricular and Left Atrial Delay in Cardiac Resynchronization Therapy Responder and Non-responder with Sinus Rhythm
Conference:World Congress on Medical Physics and Biomedical Engineering, June 3-8, 2018, Prague, Czech Republic
Author:Gudrun Dannberg, Tobias Heinke, Helmut Kühnert, Matthias HeinkeStaff MemberORCiDGND
Year of Publication:2018
Creating Corporation:The International Federation for Medical and Biological Engineering, IFMBE
Place of publication:Singapore
Publisher:Springer
First Page:139
Last Page:142
Parent Title (English):World Congress on Medical Physics and Biomedical Engineering 2018 : IFMBE Proceedings
Editor:Lenka Lhotska, Lucie Sukupova, Igor Lacković, Geoffrey S. Ibbott
Volume:68/2
ISBN:978-981-10-9038-7 (eBook)
ISBN:978-981-10-9037-0 (Softcover)
ISSN:1433-9277
DOI:https://doi.org/10.1007/978-981-10-9038-7_25
Language:English
Inhaltliche Informationen
Institutes:Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019)
Institutes:Bibliografie
Tag:Atrioventricular delay; Biventricular pacing; Cardiac resynchronization therapy; Left atrial ECG; Left atrial delay; Left cardiac ECG; Transesophageal electrocardiography
Formale Angaben
Open Access: Closed Access 
Licence (German):License LogoUrheberrechtlich geschützt