Novel telemetric signal averaging ECG approach to determine electrical atrial and ventricular conduction delays in implantable cardioverter defibrillator patients

  • Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical right atrial (RA), left atrial (LA), right ventricular (RV) and LV conduction delay with novel telemetric signal averagingCardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical right atrial (RA), left atrial (LA), right ventricular (RV) and LV conduction delay with novel telemetric signal averaging electrocardiography (SAECG) in implantable cardioverter defibrillator (ICD) P to better select P for CRT and to improve hemodynamics in cardiac pacing. Methods: ICD-P (n=8, age 70.8 ± 9.0 years; 2 females, 6 males) with VVI-ICD (n=4), DDD-ICD (n=3) and CRT-ICD (n=1) (Medtronic, Inc., Minneapolis, MN, USA) were analysed with telemetric ECG recording by Medronic programmer 2090, ECG cable 2090AB, PCSU1000 oscilloscope with Pc-Lab2000 software (Velleman®) and novel National Intruments LabView SAECG software. Results: Electrical RA conduction delay (RACD) was measured between onset and offset of RA deflection in the RAECG. Interatrial conduction delay (IACD) was measured between onset of RA deflection and onset of far-field LA deflection in the RAECG. Interventricular conduction delay (IVCD) was measured between onset of RV deflection in the RVECG and onset of LV deflection in the LVECG. Telemetric SAECG recording was possible in all ICD-P with a mean of 11.7 ± 4.4 SAECG heart beats, 97.6 ± 33.7 ms QRS duration, 81.5 ± 44.6 ms RACD, 62.8 ± 28.4 ms RV conduction delay, 143.7 ± 71.4 ms right cardiac AV delay, 41.5 ms LA conduction delay, 101.6 ms LV conduction delay, 176.8 ms left cardiac AV delay, 53.6 ms IACD and 93 ms IVCD. Conclusions: Determination of RA, LA, RV and LV conduction delay, IACD, IVCD, right and left cardiac AV delay by telemetric SAECG recording using LabView SAECG technique may be useful parameters of atrial and ventricular desynchronization to improve P selection for CRT and hemodynamics in cardiac pacing.…zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar

Statistik

frontdoor_oas
Metadaten
Dokumentart:Konferenzveröffentlichung
Art der Konferenzveröffentlichung:Konferenz-Abstract
Zitierlink: https://opus.hs-offenburg.de/340
Bibliografische Angaben
Titel (Englisch):Novel telemetric signal averaging ECG approach to determine electrical atrial and ventricular conduction delays in implantable cardioverter defibrillator patients
Konferenzangaben:BMT 2012: Annual Conference of the German Society for Biomedical Engineering / DGBMT Jahrestagung (45. : 16.-19. September 2012 : Jena)
Verfasserangaben:Anja Töpfer, Ingolf Wehsener, Bruno IsmerStaff MemberGND, Helmut Kühnert, Jakob Allmann, Daniela Eisenträger, Hans Reiner Figulla, Matthias HeinkeStaff MemberORCiDGND
Erscheinungsjahr:2012
Datum der Erstveröffentlichung:30.08.2012
Veröffentlichende Institution:Hochschule Offenburg
Titel verleihende Institution:Hochschule Offenburg
Verlagsort:Berlin, Boston
Verlag:Walter de Gruyter
Erste Seite:6
Letzte Seite:9
Titel des übergeordneten Werkes (Englisch):Biomedical Engineering / Biomedizinische Technik
Jahrgang (Band):57
Heft (Ausgabe):SI-1 Track-F
ISSN:0013-5585 (Print)
ISSN:1862-278X (Online)
DOI:https://doi.org/10.1515/bmt-2012-4170
Sprache:Englisch
Inhaltliche Informationen
Fakultäten / Einrichtungen:Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019)
Sammlungen der Hochschule Offenburg:Bibliografie
DDC-Sachgruppen:600 Technik, Medizin, angewandte Wissenschaften
Freies Schlagwort / Tag:Herzschrittmacher; Signaltechnik; Telemetrie
Formale Angaben
Open-Access-Status: Open Access 
Lizenz (Deutsch):License LogoUrheberrechtlich geschützt