Volltext-Downloads (blau) und Frontdoor-Views (grau)

Analysing-software for electrocardiographic desynchronization – which parameters needs the physician?

  • Introduction: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical ventricular desynchronization with transthoracic and transesophageal signal averaging electrocardiography in HF, toIntroduction: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical ventricular desynchronization with transthoracic and transesophageal signal averaging electrocardiography in HF, to better select patients for CRT. Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association (NYHA) class 2.8 ± 0.5, 28.6 ± 12.6 % LV ejection fraction and 155 ± 24 ms QRS duration (QRSD) were analysed with transthoracic and transesophageal electrocardiogram recording and novel National Intruments LabView 2009 signal averaging software. Esophageal TO Osypka catheter was perorally applied to the esophagus and placed in the position of maximum LV de-flection. The 0.05-Hz high-pass filtered surface electrocardiogram and the 10-Hz high-pass filtered bipolar transesophageal electrocardiogram were recorded with Bard EP-System and 1000-Hz sampling rate. Results: Transesophageal LV electrogram recording was possible in all HF patients (n=13). Transesophageal interventricular conduction delay (IVCD) was 51 ± 19 ms and measured between the earliest onset of QRS in the 12-channel surface electrocardiogram and the onset of the LV deflection in the transesophageal electrocardiogram. Transesophageal intra-left ventricular delay (LVCD) was 90 ± 16 ms and measured between the onset and offset of the LV deflection in the transesophageal electrocardiogram. QRSD to transesophageal IVCD ratio was 3.43 ± 1.31 ms, QRSD to transesophageal LVCD ratio was 1.75 ± 0.28 ms and QRSD was evaluated between onset and offset of QRS signal in the 12-channel surface electrocardiogram. Conclusion: Determination of IVCD, LVCD, QRSD-to-IVCD-ratio and QRSD-to-LVCD-ratio by transesophageal LV electrogram recording with LabView 2009 signal averaging technique may be useful parameters of ventricular desynchronisation to improve patient selection for CRT.…zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar

Statistik

frontdoor_oas
Metadaten
Dokumentart:Konferenzveröffentlichung
Art der Konferenzveröffentlichung:Konferenz-Abstract
Zitierlink: https://opus.hs-offenburg.de/604
Bibliografische Angaben
Titel (Englisch):Analysing-software for electrocardiographic desynchronization – which parameters needs the physician?
Konferenzangaben:BMT 2011: Conference of the German Society for Biomedical Engineering / DGBMT Jahrestagung (45. : 27.-30. September 2011 : Freiburg, Deutschland)
Verfasserangaben:Daniela Eisenträger, Anna Haltenberger, Bruno IsmerStaff MemberGND, Martin Lorenz, Kerstin Straube, Anja Töpfer, Jakob Allmann, Hans Reiner Figulla
Erscheinungsjahr:2011
Verlagsort:Berlin, Boston
Verlag:Walter de Gruyter
Seitenanzahl:1
Erste Seite:6
Titel des übergeordneten Werkes (Mehrsprachig):Biomedical Engineering / Biomedizinische Technik
Jahrgang (Band):56
Heft (Ausgabe):S1
ISSN:0013-5585 (Print)
ISSN:1862-278X (Online)
DOI:https://doi.org/10.1515/bmt.2011.850
Sprache:Englisch
Inhaltliche Informationen
Fakultäten / Einrichtungen:Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019)
Sammlungen der Hochschule Offenburg:Bibliografie
Formale Angaben
Open-Access-Status: Closed Access 
Lizenz (Deutsch):License LogoUrheberrechtlich geschützt