Refine
Year of publication
Document Type
- Conference Proceeding (71)
- Article (reviewed) (15)
- Patent (11)
- Contribution to a Periodical (8)
- Article (unreviewed) (2)
Conference Type
- Konferenz-Abstract (55)
- Konferenzartikel (12)
- Konferenz-Poster (4)
Language
- English (80)
- German (25)
- Other language (1)
- Multiple languages (1)
Is part of the Bibliography
- yes (107)
Keywords
- CST (7)
- HF-Ablation (7)
- CRT (6)
- Herzrhythmusmodell (6)
- Heart rhythm model (5)
- Herzkrankheit (5)
- Modeling and simulation (5)
- Kardiale Resynchronisationstherapie (4)
- Synchronisierung (4)
- heart rhythm model (4)
- Cardiac resynchronization therapy (3)
- Herzschrittmacher (3)
- Vorhofflimmern (3)
- pulmonary vein isolation (3)
- Ablation (2)
- Atrial fibrillation (2)
- Bioimpedance measurement (2)
- Cardiac Resynchronization Therapy (2)
- Cryoballoon catheter ablation (2)
- Elektrokardiogramm (2)
- IVD (2)
- Katheterablation (2)
- Kryoballonkatheter (2)
- Modellierung und Simulation (2)
- Pulmonalvenenisolation (2)
- Signaltechnik (2)
- Simulation (2)
- Supraventricular tachycardia (2)
- Triggerstabilität (2)
- atrial fibrillation (2)
- cardiac ablation (2)
- cardiac resynchronization therapy (2)
- esophageal catheter (2)
- heart rhythm simulation (2)
- 3D modeling (1)
- 3D print (1)
- 3D-Druck (1)
- 3D-Modelling (1)
- 3d Heart Simulation (1)
- 3d print (1)
- AV nodal reentry tachycardia (1)
- AV reentrant tachycardia (1)
- Atrioventricular delay (1)
- Bioimpedanzmessung (1)
- Biventricular pacing (1)
- Cardiac modelling (1)
- Catheter Ablation (1)
- EKG (1)
- EPU (1)
- Electrode Model (1)
- Electromagnetic and thermal simulation (1)
- Elektrokardiografie (1)
- Elektrophysiologie (1)
- Elektrophysiologische Untersuchung (1)
- Esophageal catheter (1)
- Esophageal electrode (1)
- Eöelktrokardiogramm (1)
- Fractionated atrial signals (1)
- Fractionated ventricular signals (1)
- HF Ablation (1)
- Heart Rhythm Simulation (1)
- Heart rhythm simulation (1)
- Heilkunde (1)
- Hemodynamic monitoring (1)
- Herz (1)
- Herzfrequenz (1)
- Herzinsuffizienz (1)
- Herzkatheterablation (1)
- Herzmuskelkrankheit (1)
- Herzrhythmusstörung (1)
- High frequency ablation (1)
- His-Bundle Pacing (1)
- His-bundle pacing (1)
- Hochfrequenzablation (1)
- Kardiologie (1)
- Left atrial ECG (1)
- Left atrial delay (1)
- Left cardiac ECG (1)
- Multiside heart stimulation (1)
- Neurostimulation (1)
- Physiological Pacing (1)
- Physiological cardiac pacing (1)
- Pulmonary vein isolation (1)
- Schrittmacher (1)
- Signal averaging ECG (1)
- Simulation und Modellierung (1)
- Spectral-temporal mapping (1)
- Spinal cord stimulation (1)
- Steuerung (1)
- Supraventricular Tachycardia (1)
- Supraventrikuläre Tachyarrhythmien (1)
- Synchronisationstherapie (1)
- Telemetrie (1)
- Transesophageal electrocardiography (1)
- Transesophageal left atrial pacing (1)
- Transesophageal neurostimulation (1)
- Transösophageale Neurostimulation (1)
- Ventricular tachycardia (1)
- Verzögerung (1)
- atrial flutter (1)
- biomechanical stimulation (1)
- biventricular pacing (1)
- biventricular stimulation (1)
- cardiac contractility modulation (1)
- cardiac resynchronisation therapy (1)
- catheter ablation (1)
- chronic heart failure (1)
- computer simulation technology (1)
- cryo ablation (1)
- cryoballoon (1)
- electrophysiological investigation (1)
- elektrische Felder (1)
- heart failure (1)
- impedance cardiography (1)
- kardiale Resynchronisationstherapie (1)
- left ventricular ECG (1)
- nuclear imaging (1)
- radiofrequency ablation (1)
- semi-invasive electrocardiography (1)
- signal averaging (1)
- spinal cord stimulation (1)
- thermische Felder (1)
- transesophageal ECG (1)
- transesophageal atrial pacing (1)
- transesophageal electrical pacing (1)
- transesophageal neurostimulation (1)
- ventricular tachycardia (1)
- virtual simulations (1)
- wavelet transformation (1)
- Ösophaguselektrodensonde (1)
- Ösophaguskatheter (1)
- Überwachung (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (76)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (28)
- POIM - Peter Osypka Institute of Medical Engineering (12)
- CRT - Campus Research & Transfer (2)
- Zentrale Einrichtungen (2)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (1)
Open Access
- Open Access (70)
- Closed Access (29)
- Bronze (4)
- Closed (2)
ECG simulators, available on the market, imitate the electric activity of the heart in a simplified manner. Thus, they are suitable for education purposes but not really for testing algorithms to recognize complex arrhythmias needed for pacemakers and implantable defibrillators. Especially certain discrimination between various morphologies of atrial and ventricular fibrillation needs simulators providing native electrograms of different patients’ heart rhythm events. This explains the necessity to develop an ECG simulator providing high-resolution native intracardiac and surface electrograms of in-vivo rhythm events. In this paper we demonstrate an approach for an ECG simulator based on a consumer multichannel soundcard and a corresponding software application for a laptop computer. This Live-ECG Simulator is able to handle invasive electrogram recordings from electrophysiological studies and send the data to a modified external soundcard for subsequent digital to analog conversion. The hardware is completed with an electronic circuit providing level adjustment to adapt the output amplitude to the input conditions of several cardiac implants.
AV delay (AVD) optimization is mandatory in cardiac resynchronization (CRT) for heart failure. Several time consuming methods exist. We initialized development of left-atrial electrogram (LAE) feature for Biotronik ICS3000 programmer. It can be utilized to approximate optimal AV delay in CRT patients with pacing systems irrespective of make and model. Using this feature, we studied the share of interatrial conduction intervals (IACT) on individual echo AVD in 45 CRT patients (34m, 11f, mean age 69±6yrs.). The percentage of IACT on optimal echo AVD resulted in44.5±22.1% for VDD and 70.7±10.9% for DDD operation. In all patients, optimal echo AVDs exceeded the individual IACT by a duration of 52.5±33.3ms (p<0.001), at mean. Therefore, if AV delay optimization is not possible or not practicable in CRT patients, AVD should be approximated by individually measuring IACT and adding about 50ms.
AV delay (AVD) optimization can improve hemodynamics and avoid nonresponding to cardiac resynchronization therapy (CRT). AVD can be approximated by the sum of the individual implant-related interatrial conduction interval and a mean electromechanical interval of about 50ms. We searched for methods to facilitate automatic, implant-based AV delay optimization. In 25 patients (19m, 6f, age: 65±8yrs.) with Medtronic Insync III Marquis CRT-D series systems and left ventricular electrode at lateral or posterolateral wall, we determined interatrial conduction intervals by telemetric left ventricular tip versus superior vena cava coil electrogram (LVCE). Compared with esophageal measurements, the duration of optimal AV delay by LVCE showed good correlation (k=0.98, p=0.01) with a difference of 1.5±4.9ms, only. Therefore, LVCE is feasible to determine interatrial conduction intervals in order to automate AV delay optimization in CRT-D pacing promising increased accuracy compared to other algorithms.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients with sinus rhythm and ventricular desynchronisation. The aim of this study was to evaluate interventricular conduction delay (IVCD) and interatrial conduction delay (IACD) before and after premature ventricular contractions (PVC) in HF patients.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association functional class 2,8 ± 0.5, left ventricular (LV) ejection fraction 28,6 ± 12,6 %, 154 ± 25 ms QRS duration and PVC were analysed with bipolar transesophageal LV and left atrial electrogram recording and National Instruments LabView 2009 software. The level of significance of the t-test is 0,005.
Results: QRS duration increases during PVC (188 ± 32 ms) in comparison to the beat before (154 ± 25 ms, P = ) and after PVC (152 ± 25 ms,). IVCD increases during PVC up to 65 ± 33 ms (51 ± 19 ms in the beat before PVC, P=0.18, 49 ± 19 ms after PVC, P = 0.12). Intra-LV delay of 90 ± 16 ms is not different in the beat before PVC, 90 ± 14 ms during PVC (P = 0.99) and 94 ± 16 ms in the beat after PVC (P = 0.38). IACD is not significantly PVC influenced (67 ± 12 ms before PVC and 65 ± 13 ms after PVC, P = 0.71). Intra-left atrial conduction delay is not significant longer during PVC (57 ± 28 ms) than in the beat before PVC (54 ± 13 ms, P = 0.51) or after PVC (54 ± 8 ms, P = 0.45). PQ duration increases significantly after PVC (224 ± 95 ms) in comparison to the beat before PVC (176± 29 ms, P =...).
Conclusion: Transesophageal left cardiac electrocardiography with LabView 2009 software can improve evaluation of IVCD and IACD before, during and after PVC in HF patient selection for CRT.
In cardiac resynchronization therapy (CRT) for heart failure, individualization of the AV delay is essential to improve hemodynamics and to minimize non-responder rate. In patients in sinus rhythm having additional disposition to bradycardia, optimization is necessary for both situations, atrial sensing and pacing. Therefore, echo-optimization is the goldstandard but time consuming. Unfortunately, it depends on the particular CRT systems parameter set if the resulting individually optimal AV delays can be programmed or not. Some CRT systems provide a set of AV delays for DDD operation combined with a set of the pace-sense-compensation to optimize the AV delay in DDD and VDD operation. The pace-sense-compensation (PSC) can be defined by the difference of implant-related interatrial conduction intervals in DDD and VDD operation measured in the esophageal left atrial electrogram. In a cohort of 96 CRT patients we found mean PSC of 59-35ms ranging between 0-143ms. As a consequence, allowing 10ms tolerance, AVD optimization is completely impossible in one of the two modes, VDD or DDD operation, in 34 (35%) or 5 (5%) patients with implants restricting the PSC range to 60ms or 100ms, respectively. Thus, we propose companies to provide CRT systems with programmable pace-sense- compensation between 0ms and 150ms.
Electrical velocimetry to optimize VV delay in biventricular VVIR and DDD pacing for heart failure
(2011)
Introduction: VV delay (VVD) is the only parameter to hemodynamically optimize cardiac resynchronization therapy (CRT) for patients with atrial fibrillation (AF). Electrical velocimetry (EV) has been established to monitor thoracic electrical conductivity and to calculate hemodynamic surrogate parameters. We compared the response of this method to hemodynamic parameter changes between CRT patients with sinus rhythm (SR) and patients with AF.
Methods: VVD was individualized in 17 CRT patients in SR (12m, 5f, 67.0±7.2yrs.) after echo AV delay optimization and in 11 CRT patients in AF (10m, 1f, 69.8±9.6yrs.) using the Aesculon Cardiovascular Monitor (Osypka Medical, Berlin, Germany). Serial 30s EV recordings were accomplished, decreasing the VVD stepwise by 10ms from +60ms to -60ms between right and left ventricular stimulus. Optimal VVD was determined by the maximum of at least two of the three averaged parameters stroke volume (SV), cardiac output (CO) and cardiac index (CI). The response of SV, CO and CI was tested comparing their values in optimal VVD and suboptimal VVD. Suboptimal VVD was defined by optimal VVD±20ms.
Results: In all 28 patients in SR and AF, EV recordings resulted in optimal VVD. Between suboptimal and optimal mean VVD of 18.6±30.8ms between left and right ventricular stimulus, SV increased by 7.2±6.8%, CO by 7.8±7.2% and CI by 10.0±13.3% (all p<0.02). In the SR group with VVD of 18.8± 29.6ms, SV increased by 4.6±2.9%, CO by 5.0±2.9% and CI by 4.9±2.9% (all p<0.02). In the AF group with VVD of 18.2±4.0ms, SV increased by 10.4±8.9%, CO by 11.3±9.5% and CI by 16.4±18.2% (all p<0.02). Significant differences were not found between optimal VVD in SR and AF patients.
Conclusion: EV is a feasible serial method to individualize VVD in DDD and VVIR pacing for heart failure. Its response to hemodynamic changes demonstrates the value of EV for VVD fine-tuning.
Responder-rate in cardiac resynchronization therapy (CRT) of patients in sinus rhythm (SR) or atrial fibrillation (AF) mainly depends on accurat selection, optimal position of the left ventricular electrode and individualization of hemodynamical parameters of the implanted biventricular pacing system during follow-up. High resolution esophageal left heart electrocardiography offers a quick and semi-invasive approach to the electrical activity of left atrium and left ventricle. It was used in 62 heart failure patients in sinus rhythm and 11 in atrial fibrillation after implantation of CRT systems to compare the semi-invasive interventricular conduction delay (IVCDE) with QRS width. In all of the patients, guideline decision for CRT was linked with IVCDE of about 40ms and up. From logical point of view, IVCDE provides the minimal target interval for the left ventricular electrode placement in order to exclude non-responders. Esophageal measurement of interatrial conduction intervals in VDD and DDD pacing was utilized to individualize the AV delay and to exclude adverse hemodynamic effects.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.