Refine
Year of publication
Document Type
- Contribution to a Periodical (15)
- Report (5)
- Conference Proceeding (4)
- Article (reviewed) (3)
Conference Type
- Konferenzartikel (4)
Has Fulltext
- yes (27) (remove)
Is part of the Bibliography
- yes (27) (remove)
Keywords
- Gebäudeklimatisierung (4)
- Energietechnik (2)
- Feldtest (2)
- Klimatechnik (2)
- Monitoring (2)
- Raumtemperatur (2)
- Sanierung (2)
- Analyse (1)
- Battery energy management system (1)
- Betriebsanalyse (1)
Institute
Open Access
- Open Access (27)
- Bronze (10)
- Gold (2)
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
In vielen Schulgebäuden der Region südlicher Oberrhein zeigte sich seit Beginn dieses Jahrhunderts eine verstärkte Überhitzungstendenz. Besonders bei energetisch sanierten Schulen und durch die Umstellung des Schulbetriebs auf den Ganztagsunterricht zeigt sich eine stärkere Wärmebelastung durch die sommerlichen Temperaturen. Die Stadt Offenburg sah hier einen wichtigen Handlungsbedarf, um Klassenräume ohne den Einsatz energieintensiver Kältemaschinen thermisch zu entlasten. Durch einen deutlichen Anstieg beim Energieeinsatz für Kühlmaßnahmen würden die starken Einspareffekte bei den Heizkosten im Sommer neutralisiert. Interessant waren deshalb nachhaltige Lösungen die bei niedrigem Primärenergieeinsatz ein hohes Reduktionspotenzial bei der Kühllast bewirken. Verfahren der natürlichen Gebäudeklimatisierung führten in Zusammenarbeit mit der Forschungsgruppe nachhaltige Energietechnik der Hochschule Offenburg zu unterschiedlichen Nachtlüftungsstrategien zusammen mit ergänzenden Wärmeschutzmaßnahmen.
Ziel des Pilotprojektes EnMa-HAW ist die Erarbeitung und Erprobung technisch und organisatorisch übertragbarer Konzepte für ein automationsgestütztes Energiemanagement an allen Hochschulen für angewandte Wissenschaften im Land Baden-Württemberg. Das Energiemanagement wird technisch mittels Messtechnik, Datenerfassung, Datenspeicherung und Visualisierung umgesetzt und organisatorisch mit einem Energiezirkel in den Hochschulen verankert.
Recently, photovoltaic (PV) with energy storage systems (ESS) have been widely adopted in buildings to overcome growing power demands and earn financial benefits. The overall energy cost can be optimized by combining a well-sized hybrid PV/ESS system with an efficient energy management system (EMS). Generally, EMS is implemented within the overall functions of the Building Automation System (BAS). However, due to its limited computing resources, BAS cannot handle complex algorithms that aim to optimize energy use in real-time under different operating conditions. Furthermore, islanding the building's local network to maximize the PV energy share represents a challenging task due to the potential technical risks. In this context, this article addresses an improved approach based on upgrading the BAS data analytics capability by means of an edge computing technology. The edge communicates with the BAS low-level controller using a serial communication protocol. Taking advantage of the high computing ability of the edge device, an optimization-based EMS of the PV/ESS hybrid system is implemented. Different testing scenarios have been carried out on a real prototype with different weather conditions, and the results show the implementation feasibility and technical performance of such advanced EMS for the management of building energy resources. It has also been proven to be feasible and advantageous to operate the local energy network in island mode while ensuring system safety. Additionally, an estimated energy saving improvement of 6.23 % has been achieved using optimization-based EMS compared to the classical rule-based EMS, with better ESS constraints fulfillment.
Building energy management systems (BEMSs), dedicated to sustainable buildings, may have additional duties, such as hosting efficient energy management systems (EMSs) algorithms. This duty can become crucial when operating renewable energy sources (RES) and eventual electric energy storage systems (ESSs). Sophisticated EMS approaches that aim to manage RES and ESSs in real time may need high computing capabilities that BEMSs typically cannot provide. This article addresses and validates a fuzzy logic-based EMS for the optimal management of photovoltaic (PV) systems with lead-acid ESSs using an edge computing technology. The proposed method is tested on a real smart grid prototype in comparison with a classical rule-based EMS for different weather conditions. The goal is to investigate the efficacy of islanding the building local network as a control command, along with ESS power control. The results show the implementation feasibility and performance of the fuzzy algorithm in the optimal management of ESSs in both operation modes: grid-connected and islanded modes.
In this paper, a new method is demonstrated for online remote simulation of photovoltaic systems. The required communication technology for the data exchange is introduced and the methods of PV generator parameter extraction for the simulation models are analysed. The method shown for parameter extraction from the manufacturer data is especially useful for the commissioning procedure, where the measured installed power is transferred to standard test conditions using the simulation model and can then be easily compared with the design power. At a simulation accuracy of 2% using the software environment INSEL ® any problems with the PV generator can reliably be detected. Online simulation of a grid connected PV generator is then carried out during the operation of the photovoltaic plant. The visualisation includes both the monitored and the simulated online data sets, so that a very efficient fault detection scheme is available. The method is implemented and validated on several grid connected photovoltaic power plants in Germany. It is excellently suited to provide automatic and real time fault detection and significantly improve the commissioning procedure for photovoltaic plants of all sizes.
Das Projektvorhaben "Energienetzmanagement dezentraler KWK‐Anlagen mit diversen Verbraucherstrukturen", das vom Innovationsfonds der badenova AG & Co KG von Mai 2012 bis Juli 2016 unter der Fördernummer 2012‐09 gefördert wurde kann aus Sicht des Projektnehmers Hochschule Offenburg und seiner Partner Stadt Offenburg und G. und M. Zapf Energie GbR mbH als sehr erfolgreich umgesetztes Fördervorhaben bezeichnet werden. Während der ca. vier Jahre Projektlaufzeit konnten mehrere Reallabore geschaffen werden, die an die Eigenschaften eines Subnetzes in einem Smart Grid sehr nah herangeführt wurden. Alle Objekte bzw. Netzstrukturen verfügen über typische Komponenten eines Microgrids mit Energiequellen, Speichern und Senken. Auch wurde die Trigeneration als Netzvariante mit Strom‐ Wärme und Kältebereitstellung aufgegriffen und für Verteilnetzmodelle der Niederspannungsebene beschrieben. Ausgehend von einem Mikronetzmodell für jede Energieart kann hinter jeder Trafostation eine beliebig komplexe Energieversorgungsstruktur aufgespannt werden.