Refine
Year of publication
Document Type
- Article (reviewed) (155) (remove)
Has Fulltext
- yes (155) (remove)
Is part of the Bibliography
- yes (155) (remove)
Keywords
- 3D printing (7)
- blockchain (5)
- Blockchain (4)
- lithium-ion battery (4)
- mechanical properties (4)
- neuroprosthetics (4)
- Acceptance (3)
- COVID-19 (3)
- Götz von Berlichingen (3)
- amputee (3)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (70)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (53)
- INES - Institut für nachhaltige Energiesysteme (35)
- Fakultät Wirtschaft (W) (20)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (14)
- POIM - Peter Osypka Institute of Medical Engineering (11)
- Fakultät Medien (M) (ab 22.04.2021) (10)
- ACI - Affective and Cognitive Institute (4)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (4)
- IMLA - Institute for Machine Learning and Analytics (4)
Open Access
- Open Access (153)
- Gold (59)
- Hybrid (19)
- Diamond (10)
- Closed (1)
- Closed Access (1)
- Grün (1)
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
This article presents a comparative experimental study of the electrical, structural and chemical properties of large‐format, 180 Ah prismatic lithium iron phosphate (LFP)/graphite lithium‐ion battery cells from two different manufacturers. These cells are particularly used in the field of stationary energy storage such as home‐storage systems. The investigations include (1) cell‐to‐cell performance assessment, for which a total of 28 cells was tested from each manufacturer, (2) electrical charge/discharge characteristics at different currents and ambient temperatures, (3) internal cell geometries, components, and weight analysis after cell opening, (4) microstructural analysis of the electrodes via light microscopy and scanning electron microscopy, (5) chemical analysis of the electrode materials using energy‐dispersive X‐ray spectroscopy, and (6) mathematical analysis of the electrode balances. The combined results give a detailed and comparative insight into the cell characteristics, providing essential information needed for system integration. The study also provides complete and self‐consistent parameter sets for the use in cells models needed for performance prediction or state diagnosis.
Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects’ body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab’s file exchange server (“getBeltVelocity.m”) allowing TBV tracking to become standard practice in locomotion research.
Background: Running overuse injuries (ROIs) occur within a complex, partly injury-specific interplay between training loads and extrinsic and intrinsic risk factors. Biomechanical risk factors (BRFs) are related to the individual running style. While BRFs have been reviewed regarding general ROI risk, no systematic review has addressed BRFs for specific ROIs using a standardized methodology.
Objective: To identify and evaluate the evidence for the most relevant BRFs for ROIs determined during running and to
suggest future research directions.
Design: Systematic review considering prospective and retrospective studies. (PROSPERO_ID: 236,832).
Data Sources: PubMed. Connected Papers. The search was performed in February 2021.
Eligibility Criteria: English language. Studies on participants whose primary sport is running addressing the risk for the seven most common ROIs and at least one kinematic, kinetic (including pressure measurements), or electromyographic BRF. A BRF needed to be identified in at least one prospective or two independent retrospective studies. BRFs needed to be determined during running.
Results: Sixty-six articles fulfilled our eligibility criteria. Levels of evidence for specific ROIs ranged from conflicting to moderate evidence. Running populations and methods applied varied considerably between studies. While some BRFs appeared for several ROIs, most BRFs were specific for a particular ROI. Most BRFs derived from lower-extremity joint kinematics and kinetics were located in the frontal and transverse planes of motion. Further, plantar pressure, vertical ground reaction force loading rate and free moment-related parameters were identified as kinetic BRFs.
Conclusion: This study offers a comprehensive overview of BRFs for the most common ROIs, which might serve as a starting point to develop ROI-specific risk profiles of individual runners. We identified limited evidence for most ROI-specific risk factors, highlighting the need for performing further high-quality studies in the future. However, consensus on data collection standards (including the quantification of workload and stress tolerance variables and the reporting of injuries) is warranted.
Background:
Ankle braces aim to reduce lateral ankle sprains. Next to protection, factors influencing user compliance, such as sports performance, motion restriction, and users’ perceptions, are relevant for user compliance and thus injury prevention. Novel adaptive protection systems claim to change their mechanical behavior based on the intensity of motion (eg, the inversion velocity), unlike traditional passive concepts of ankle bracing.
Purpose:
To compare the performance of a novel adaptive brace with 2 passive ankle braces while considering protection, sports performance, freedom of motion, and subjective perception.
Study Design:
Controlled laboratory study.
Methods:
The authors analyzed 1 adaptive and 2 passive (one lace-up and one rigid brace) ankle braces, worn in a low-cut, indoor sports shoe, which was also the no-brace reference condition. We performed material testing using an artificial ankle joint system at high and low inversion velocities. Further, 20 male, young, healthy team sports athletes were analyzed using 3-dimensional motion analysis in sports-related movements to address protection, sports performance, and active range of motion dimensions. Participants rated subjective comfort, stability, and restriction experienced when using the products.
Results:
Subjective stability rating was not different between the adaptive and passive systems. The rigid brace was superior in restricting peak inversion during the biomechanical testing compared with the passive braces. However, in the material test, the adaptive brace increased its stiffness by approximately 400% during the fast compared with the slow inversion velocities, demonstrating its adaptive behavior and similar stiffness values to passive braces. We identified minor differences in sports performance tasks. The adaptive brace improved active ankle range of motion and subjective comfort and restriction ratings.
Conclusion:
The adaptive brace offered similar protective effects in high-velocity inversion situations to those of the passive braces while improving range of motion, comfort, and restriction rating during noninjurious motions.
Clinical Relevance:
Protection systems are only effective when used. Compared with traditional passive ankle brace technologies, the novel adaptive brace might increase user compliance by improving comfort and freedom of movement while offering similar protection in injurious situations.
Background: Many countries have restricted public life in order to contain the spread of the novel coronavirus (SARS-CoV2). As a side effect of related measures, physical activity (PA) levels may have decreased.
Objective: We aimed (1) to quantify changes in PA and (2) to identify variables potentially predicting PA reductions.
Methods: A systematic review with random-effects multilevel meta-analysis was performed, pooling the standardized mean differences in PA measures before and during public life restrictions.
Results: A total of 173 trials with moderate methodological quality (modified Downs and Black checklist) were identified. Compared to pre-pandemic, total PA (SMD − 0.65, 95% CI − 1.10 to − 0.21) and walking (SMD − 0.52, 95% CI − 0.29 to − 0.76) decreased while sedentary behavior increased (SMD 0.91, 95% CI: 0.17 to 1.65). Reductions in PA affected all intensities (light: SMD − 0.35, 95% CI − 0.09 to − 0.61, p = .013; moderate: SMD − 0.33, 95% CI − 0.02 to − 0.6; vigorous: SMD − 0.33, − 0.08 to − 0.58, 95% CI − 0.08 to − 0.58) to a similar degree. Moderator analyses revealed no influence of variables such as sex, age, body mass index, or health status. However, the only continent without a PA reduction was Australia and cross-sectional trials yielded higher effect sizes (p < .05).
Conclusion: Public life restrictions associated with the COVID-19 pandemic resulted in moderate reductions in PA levels and large increases in sedentary behavior. Health professionals and policy makers should therefore join forces to develop strategies counteracting the adverse effects of inactivity.
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.
Novel approaches for the design of assistive technology controls propose the usage of eye tracking devices such as for smart wheelchairs and robotic arms. The advantages of artificial feedback, especially vibrotactile feedback, as opposed to their use in prostheses, have not been sufficiently explored. Vibrotactile feedback reduces the cognitive load on the visual and auditory channel. It provides tactile sensation, resulting in better use of assistive technologies. In this study the impact of vibration on the precision and accuracy of a head-worn eye tracking device is investigated. The presented system is suitable for further research in the field of artificial feedback. Vibration was perceivable for all participants, yet it does not produce any significant deviations in precision and accuracy.
Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes.
Emerging applications in soft robotics, wearables, smart consumer products or IoT-devices benefit from soft materials, flexible substrates in conjunction with electronic functionality. Due to high production costs and conformity restrictions, rigid silicon technologies do not meet application requirements in these new domains. However, whenever signal processing becomes too comprehensive, silicon technology must be used for the high-performance computing unit. At the same time, designing everything in flexible or printed electronics using conventional digital logic is not feasible yet due to the limitations of printed technologies in terms of performance, power and integration density. We propose to rather use the strengths of neuromorphic computing architectures consisting in their homogeneous topologies, few building blocks and analog signal processing to be mapped to an inkjet-printed hardware architecture. It has remained a challenge to demonstrate non-linear elements besides weighted aggregation. We demonstrate in this work printed hardware building blocks such as inverter-based comprehensive weight representation and resistive crossbars as well as printed transistor-based activation functions. In addition, we present a learning algorithm developed to train the proposed printed NCS architecture based on specific requirements and constraints of the technology.