Refine
Year of publication
- 2013 (54) (remove)
Document Type
- Article (reviewed) (18)
- Article (unreviewed) (13)
- Conference Proceeding (11)
- Book (4)
- Contribution to a Periodical (3)
- Part of a Book (2)
- Report (2)
- Patent (1)
Conference Type
- Konferenzartikel (10)
- Sonstiges (1)
Is part of the Bibliography
- yes (54) (remove)
Keywords
- Dünnschichtchromatographie (4)
- Biogas (3)
- Konstruktion (3)
- Bürohaus (2)
- Energieversorgung (2)
- Enzym (2)
- Gebäudeklimatisierung (2)
- Haustechnik (2)
- Hochtemperaturbrennstoffzelle (2)
- Kohlenstoff (2)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (54) (remove)
Open Access
- Open Access (16)
- Closed Access (14)
- Bronze (3)
- Closed (2)
- Gold (1)
A series of isostructural 3D coordination polymers (3)∞[M(tdc)(bpy)] (M(2+) = Zn(2+), Cd(2+), Co(2+), Fe(2+); tdc(2-) = 2,5-thiophenedicarboxylate; bpy = 4,4'-bipyridine) was synthesized and characterized by X-ray diffraction, thermal analysis, and gas adsorption measurements. The materials show high thermal stability up to approximately 400 °C and a solvent induced phase transition. Single crystal X-ray structure determination was successfully performed for all compounds after the phase transition. In the zinc-based coordination polymer, various amounts of a second type of metal ions such as Co(2+) or Fe(2+) could be incorporated. Furthermore, the catalytic behavior of the homo- and heteronuclear 3D coordination polymers in an oxidation model reaction was investigated.
Die Weltwirtschaftskrise 2008 hat mit ihrer zeitweisen Verknappung von Acetonitril eindringlich gezeigt, dass man nicht nur auf eine einzige chromatographische Methode setzten sollte. Genau dies wird aber im Augenblick getan, denn Industrie und Forschung setzen mehrheitlich auf die High Performance Liquid Chromatography (HPLC) als die Trennmethode ihrer Wahl. Für viele Anwendungen in der Pharmazie, in der Umweltanalytik, der Lebensmittelanalytik, aber auch in der Inprozesskontrolle gibt es mit der Dünnschichtchromatografie eine Alternative.
We present a video-densitometric quantification method in combination with diode-array quantification for the methyl-, ethyl-, propyl-, and butylparaben in cosmetics. These parabens were separated on cyanopropyl bonded plates using water-acetonitrile-dioxane-ethanol-NH3 (25%) (8:2:1:1:0.05, v/v) as mobile phase. The quantification is based on UV-measurements at 255 nm and a bioeffectively-linked analysis using Vibrio fischeri bacteria. Within 5 min, a Tidas S 700 diode-array scanner (J&M, Aalen, Germany) scans 8 tracks and thus measures in total 5600 spectra in the wavelengths range from 190 to 1000 nm. The quantification range for all these parabens is from 20 to 400 ng per band, measured at 255 nm. In the V. fischeri assay a CCD-camera registers the white light of the light-emitting bacteria within 10 min. All parabens effectively suppress the bacterial light emission which can be used for quantifying within a linear range from 100 to 400 ng. Measurements were carried out using a 16-bit MicroChemi chemiluminescence system (biostep GmbH, Jahnsdorf, Germany), using a CCD camera with 4.19 megapixels. The range of linearity is achieved because the extended Kubelka-Munk expression was used for data transformation. The separation method is inexpensive, fast, and reliable.
Raman spectra from three different binary gasoline-ethanol blends (with ratios 95:5, 90:10, and 85:15) have been obtained by using a low-cost, frequency precise Fourier-transform Raman spectrometer (FT-Raman) prototype. The spectral information is presented in the range of 0 to 3500 cm-1 with a resolution of 1.66 cm-1, which is greater than the required for most liquid and solid chemical samples. This set-up delivers spectral information about the sample with a reduced spectral deviation compared to theoretical values (less than 0.4 cm-1 without compensation for instrumental response). The robust and highly fexible FT-Raman prototype presented for the spectral analysis, consisting mainly of a Michelson interferometer and a self-designed photon counter, is able to deliver high resolution and frequency precise Raman spectra from the gasoline-ethanol blends comparable to the obtained by using commercial devices. This FT-Raman set-up does not need additional complex hardware or software control and relies on re-sampling and interpolation algorithms. The qualitative spectral information obtained has been used to calculate the proportion of gasoline and ethanol present in the used chemical samples without using extra calibrations methods or chemical markers.
Der Endkundenvertrieb ist für die Bewahrung und Weiterentwicklung des Kundenstamms eines Energieversorgers essenziell. Doch um knappe Mittel im Vertrieb möglichst wirkungsvoll einsetzen zu können, wird Wissen darüber benötigt, wie sich die durchschnittlich erzielbaren Strompreise und die zu erwartende Kundenbindungsdauer zwischen verschiedenen Vertriebskanälen unterscheiden. Leitet man anhand dieser Informationen den Wert eines Kunden je Vertriebskanal ab, lässt sich treffsicherer über einzusetzende Marketing-Budgets entscheiden.