Refine
Document Type
- Conference Proceeding (9)
- Article (reviewed) (4)
- Article (unreviewed) (4)
- Book (2)
- Contribution to a Periodical (2)
- Part of a Book (1)
Conference Type
- Konferenzartikel (9)
Is part of the Bibliography
- yes (22) (remove)
Keywords
- Optik (3)
- Photonik (3)
- Radar (3)
- UWB radars (2)
- catheter ablation (2)
- imaging algorithms (2)
- medical imaging (2)
- microwave (2)
- scattering measurements (2)
- Angle of Arrival (1)
Institute
- IUAS - Institute for Unmanned Aerial Systems (22) (remove)
Open Access
- Closed (5)
- Closed Access (5)
- Open Access (4)
- Bronze (1)
Skin cancer detection proves to be complicated and highly dependent on the examiner’s skills. Millimeter-wave technologies seem to be a promising aid for the detection of skin cancer. The different water content of the skin area affected by cancer compared to healthy skin changes its reflective property. Due to limited available resources on the dielectric properties of skin cancer, especially in comparison to surrounding healthy skin, accurate simulations and evaluations are quite challenging. Therefore, comparing different results for different approaches and starting points can be difficult. In this paper, the Effective Medium Theory is applied to model skin cancer, which provides permittivity values dependent on the water content.
A method for evaluating skin cancer detection based on millimeter-wave technologies is presented. For this purpose, the relative permittivities are calculated using the effective medium theory for the benign and cancerous lesion, considering the change in water content between them. These calculated relative permittivities are further used for the simulation and evaluation of skin cancer detection using a substrate-integrated waveguide probe. A difference in the simulated scattering parameters S 11 of up to 13dB between healthy and cancerous skin can be determined in the best-case.
Chronic insomnia is defined by difficulties in falling asleep, maintaining sleep, and early morning awakening, and is coupled with daytime consequences such as fatigue, attention deficits, and mood instability. These symptoms persist over a period of at least 3 months (Diagnostic and Statistical Manual 5 criteria). Chronic insomnia can be a symptom of many medical, neurological, and mental disorders. As a disorder, it incurs substantial health-care and occupational costs, and poses substantial risks for the development of cardiovascular and mental disorders, including cognitive deficits. Family and twin studies confirm that chronic insomnia can have a genetic component (heritability coefficients between 42% and 57%), whereas the investigation of autonomous and central nervous system parameters has identified hyperarousal as a final common pathway of the pathophysiology, implicating an imbalance of sleep–wake regulation consisting of either overactivity of the arousal systems, hypoactivity of the sleep-inducing systems, or both. Insomnia treatments include benzodiazepines, benzodiazepine-receptor agonists, and cognitive behavioural therapy. Treatments currently under investigation include transcranial magnetic or electrical brain stimulation, and novel methods to deliver psychological interventions.
Hybrid SPECT/US
(2014)
This paper presents new measurements of a bronze cast from the right hand of the famous Italian violin virtuoso Nicolò Paganini (1782-1840). These are compared to anthropometric standard values. In addition, detailed dorsal and palmar views of the cast are shown. With a middle finger length of 75 mm, the palm width is 60 mm and the hand length 152 mm, which is significantly below the 5% percentile of today's standard values. Also the finger length index (0.55), the ratio of finger length to palm length (0.98) and the ratio of finger length to palm width (1.25) are significantly above normal limits. Hence, Paganini had abnormal hand measurements with a very small palm and relatively "long" fingers. This remarkable constellation, among others, could have been advantageous for his amazing skills as a violinist.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.
In automotive parking scenario, where the curb shall be detected and classified to be traversable or not, radars play an important role. There are different approaches already proposed in other works to estimate the target height. This paper assesses and compares two methods. The first is based on Angle of Arrival (AoA) estimation of input signals of multiple antennas using the Multiple-Input-Multiple-Output (MIMO) principle. The second method uses the geometry in multipath propagation of the radar echo signal for one antenna input. In this work a modified method of calculation of the curb height based on the second method is proposed. The theory of approach is mathematically proved and effectiveness is demonstrated by evaluation of measurements with a 77 GHz Frequency Modulated Continuous Wave (FMCW) radar. In order to evaluate the performance of the introduced method the mean square error (MSE) is used in the proposed scenario. This method, using only one antenna input, produced up to 3.4 times better results for curb height detection in comparison with former methods.