Refine
Year of publication
- 2015 (70) (remove)
Document Type
- Conference Proceeding (38)
- Article (reviewed) (12)
- Article (unreviewed) (8)
- Part of a Book (5)
- Patent (4)
- Book (3)
Conference Type
- Konferenzartikel (30)
- Konferenz-Abstract (6)
- Sonstiges (2)
Is part of the Bibliography
- yes (70) (remove)
Keywords
- Applikation (5)
- Abtragung (3)
- Eingebettetes System (3)
- Herz (3)
- Kommunikation (3)
- Physik (3)
- Raman-Spektroskopie (3)
- Datensicherung (2)
- Funktechnik (2)
- Herzrhythmusstörung (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (70) (remove)
Open Access
- Closed Access (32)
- Open Access (22)
- Bronze (6)
The automatic classification of the modulation format of a detected signal is the intermediate step between signal detection and demodulation. If neither the transmitted data nor other signal parameters such as the frequency offset, phase offset and timing information are known, then automatic modulation classification (AMC) is a challenging task in radio monitoring systems. The approach of clustering algorithms is a new trend in AMC for digital modulations. A novel algorithm called `highest constellation pattern matching' is introduced to identify quadrature amplitude modulation and phase shift keying signals. The obtained simulation and measurement results outperform the existing algorithms for AMC based on clustering. Finally, it is shown that the proposed algorithm works in a real monitoring environment.
Der Studienbeginn wird an der Hochschule Offenburg durch Vorbereitungskurse, sogenannte Brückenkurse, unterstützt. Wir stellen vorläufige Ergebnisse beim Einsatz von Smartphones und Tablets im Rahmen des Physik-Brückenkurses vor, bei dem die Studenten Hilfen zum selbständigen Üben durch eine App erhalten. Durch die Überarbeitung des Kurses und den Einsatz der App konnte der Teilnehmerschwund verringert werden. Die Evaluationsergebnisse bestätigen eine hohe Akzeptanz der Neuerungen seitens der Studierenden. Erste Auswertungen von Ein- und Ausgangstests deuten darauf hin, dass durch den Brückenkurs eine Angleichung der Vorkenntnisse der Studienanfänger erreicht wird, da Teilnehmer mit geringeren Vorkenntnissen tendenziell einen größeren Lernfortschritt erreichen. Durch unterschiedliche Schwierigkeitsstufen und selbstregulierte Übungsphasen in individuellem Tempo können aber auch die Erfordernisse der stärkeren Teilnehmer angemessen berücksichtigt werden.
Im Projekt bwLehrpool wurde ein verteiltes System für die flexible Nutzung von Rechnerpools durch Desktop-Virtualisierung entwickelt. Auf Basis eines zentral gebooteten Linux- Grundsystems können beliebige virtualisierbare Betriebssysteme für Lehrund Prüfungszwecke zentral bereitgestellt und lokal auf den Maschinen aus-gewählt werden. Die verschiedenen Ar- beitsumgebungen müssen nicht mehr auf den PCs installiert werden und erlauben so eine multifunktionale Nutzung von PCs und Räumen für vielfältige Lehrund Lernszenarien sowie für elektronische Prüfungen. bwLehrpool abstrahiert von der PC-Hardware vor Ort und ermöglicht den Dozenten die eigene Gestaltung und Verwaltung ihrer Softwareumgebungen als Self-Service. Darüber hinaus fördert bwLehrpool den hochschulübergreifenden Austausch von Kursumgebungen.
Cardiac resynchronization therapy (CRT) is an established therapy for heart failure patients and improves quality of life in patients with sinus rhythm, reduced left ventricular ejection fraction (LVEF), left bundle branch block and wide QRS duration. Since approximately sixty percent of heart failure patients have a normal QRS duration they do not benefit or respond to the CRT. Cardiac contractility modulation (CCM) releases nonexcitatoy impulses during the absolute refractory period in order to enhance the strength of the left ventricular contraction. The aim of the investigation was to evaluate differences in cardiac index between optimized and nonoptimized CRT and CCM devices versus standard values. Impedance cardiography, a noninvasive method was used to measure cardiac index (CI), a useful parameter which describes the blood volume during one minutes heart pumps related to the body surface. CRT patients indicate an increase of 39.74 percent and CCM patients an improvement of 21.89 percent more cardiac index with an optimized device.
In this paper an RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (system on chip) for biomedical applications is presented. A brief overview of the system design, layout techniques and verification method is dis-cussed here. The SoC includes an integrated 32 bit microcontroller, sensor interface circuit, analog to digital converter, integrated RAM, ROM and some other peripherals required for the complete passive operation. The entire chip is realized in CMOS 0.18 μm technology with a chip area of 1.52mm x 3.24 mm.
The aim of this research work was to develop a boiler model with few parameters required for energy planning. The showcase considered for this work was the boiler system of the energy center at Offenburg University of Applied Sciences. A grey box model of the boiler was developed systematically starting from model abstraction, simplification, model break-down and to the use of empirical correlations wherever necessary to describe the intermediate effects along with the use of information from manufacturer’s specification in order to reduce parameters. This strategy had resulted in a boiler model with only 6 parameters, namely, nominal burner capacity, water gallery capacity, air ratio, heat capacity of wall, thermal conductance on flue gas and hot water side. Most of these parameters can be obtained through the information available in the spec sheets and thus an energy planner will be able to parameterize the model with low effort. The model was validated with the monitored data of the showcase. It was tested for the start-up, shut-down behavior and the effect of storage.