Refine
Year of publication
- 2003 (17) (remove)
Document Type
- Conference Proceeding (5)
- Article (reviewed) (4)
- Article (unreviewed) (4)
- Book (2)
- Contribution to a Periodical (1)
- Periodical Part (1)
Conference Type
- Konferenzartikel (4)
- Konferenz-Poster (1)
Is part of the Bibliography
- yes (17) (remove)
Keywords
- Fluorescence enhancement (2)
- Arbeitszeugnis (1)
- Beurteilung (1)
- Blase (1)
- Compound identification (1)
- Densitometrie (1)
- Diode-Array TLC (1)
- Diode‐array TLC (1)
- Dünnschichtchromatographie (1)
- Fachhochschule / Geschichte (1)
Institute
Open Access
- Closed (6)
- Open Access (6)
- Closed Access (4)
- Bronze (3)
The central purpose of this paper is to present a novel framework supporting the specification, the implementation and retrieval of media streaming services. It provides an integrated service development environment comprising of a streaming service model, a service specification language and several implementation and retrieval tools. Our approach is based on a clear separation of a streaming service specification, and its implementation by a distributed application and can be used for different streaming paradigms, e.g. push and pull services.
A Simple and Reliable HPTLC Method for the Quantification of the Intense Sweetener Sucralose®
(2003)
This paper describes a simple and fast thin layer chromatography (TLC) method for the monitoring of the relatively new intense sweetener Sucralose® in various food matrices. The method requires little or no sample preparation to isolate or concentrate the analyte. The Sucralose® extract is separated on amino‐TLC‐plates, and the analyte is derivatized “reagent‐free” by heating the developed plate for 20 min at 190°C. Spots can be measured either in the absorption or fluorescence mode. The method allows the determination of Sucralose® at the levels of interest regarding foreseen European legislation (>50 mg/kg) with excellent repeatability (RSD = 3.4%) and recovery data (95%).
Fluorescence Enhancement of Pyrene Measured by Thin-Layer Chromatography with Diode-Array Detection
(2003)
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography. It offers a simple way of quantifying by measuring the optical density of the separated spots directly on the plate. A new TLC scanner has been developed which is able to measure TLC plates or HPTLC plates, at different wavelengths simultaneously, without destroying the plate surface. The system enables absorbance and fluorescence measurements in one run. Fluorescence measurements are possible without filters or other adjustments.
The measurement of fluorescence from a TLC plate is a versatile means of making TLC analysis more sensitive. Fluorescence measurements with the new scanner are possible without filters or special lamps. Improvement of the signal-to-noise ratio is achieved by wavelength bundling. During plate scanning the scattered light and the fluorescence are both emitted from the surface of the TLC plate and this emitted light provides the desired spectral information from substances on the TLC plate. The measurement of fluorescence spectra and absorbance spectra directly from a TLC plate is based on differential measurement of light emerging from sample-free and sample-containing zones.
The literature recommends dipping TLC plates in viscous liquids to enhance fluorescence. Measurement of the fluorescence and absorbance spectra of pyrene spots reveals the mechanism of enhancement of plate dipping in viscous liquids—blocked contact of the fluorescent molecules with the stationary phase or other sample molecules is responsible for the enhanced fluorescence at lower concentrations.
In conclusion, dipping in TLC analysis is no miracle. It is based on similar mechanisms observable in liquids. The measured TLC spectra are also very similar to liquid spectra and this makes TLC spec-troscopy an important tool in separation analysis.
Vorgestellt wird die Dioden-Array-Dünnschichtchromatographie als eine moderne und preiswerte Messmethode zur densitometrischen Erfassung von Substanzen auf einer DC- oder einer HPTLC-Platte. Sicher identifizierbar sind auch Substanzen mit schwachem Chromophor. Die Kubelka-Munk-Gleichung beschreibt einen linearen Zusammenhang zwischen Remissionslicht und lichtabsorbierender Stoffmenge auf der Platte. Die Auswertung im Spektralbereich von 316 bis 334 nm zeigt den Zusammenhang zwischen transformiertem Messsignal und aufgetragener Substanzmasse. Die schnelle Aufnahme von UV/vis-Spektren eröffnet der HPTLC den gesamten Bereich der Methodenvalidierung auf dem Niveau, auf welchem heute die HPLC-Analytik durchgeführt wird.
Eine gewichtige Komponente in Arbeitszeugnissen ist die Positions- und Aufgabenbeschreibung. In einer Befragung von 369 Unternehmen gaben 37,4 Prozent sogar an, für sie sei die Aufgabenbeschreibung die wichtigste Zeugniskomponente. Diese Wertschätzung gründet auf der wohl richtigen Annahme, dass die Beurteilung in Zeugnissen oft geschönt sei, die Aufgabendarstellung aber vergleichsweise wahrheitsgerechte Angaben enthalte. Es kommt wohl nicht so oft vor, dass Arbeitnehmer die Aufnahme von Tätigkeiten ins Zeugnis fordern und durchsetzen, die sie gar nicht ausgeübt haben. Demnach konzentrieren sich manche Leser auf diesen Zeugnisteil, um einen Eindruck von der Berufserfahrung eines Bewerbers zu gewinnen.
Quantitative Bestimmung von Clozapin im Serum mittels Dioden-Array Dünnschichtchromatographie
(2003)
Details design tools and techniques for high performance ASIC-design. Shows the best practices for creating reusable designs in an SoC design methodology.
Bei Arbeitszeugnisse und Personalbeurteilungen können viele Fehler auftreten. Die Objektivität des Beurteilers und des Lesers, ihre Meßgenauigkeit und letztlich die Validität des Zeugnisses können beeinträchtigt sein. Bei der Zeugniserstellung und -verwendung sind zahlreiche Fehler und Kombinationen möglich. Die Struktur dieser Fehler wird detailliert aufgezeigt. Trotz der aufgezeigten Mängel hält die Praxis am Zeugnis als Informationsmittel fest. Es gibt keinen Idealweg der Personalauswahl. Die Qualität der Personalauswahl verbessert sich durch einen Methodenmix verschiedener Mittel, in den auch das Arbeitszeugnis gehört.