The authors present an abiotically catalyzed glucose fuel cell and demonstrate its application as energy harvesting power source for a cardiac pacemaker. This is enabled by an optimized DC-DC converter operating at 40 % conversion efficiency, which surpasses commercial low-power DC-DC converters. The required fuel cell surface area can thus be reduced from about 125 cm2 to 18 cm2, which would allow for its direct integration onto the pacemaker casing.
A new miniaturized capsule with 32bit processor and bidirectional communication system is being developed for multitask application. The capsule is designed to be a platform for medical assistant application inside the body. The processor core SIRIUS has been developed, simulated, synthesized to a netlist and verified. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25 mm. The system is designed, simulated, emulated on FPGA, and routed in AMIS Technology.
A new approach of continuous phase QPSK Band-Pass modulation technique is being developed as enhancement to the QPSK modulation scheme for inductive data transmission (NFC). The modulation is based on Gaussian filtering of the phase transition from one state to the other rather than discontinuity in phase shift. The carrier is based on low frequency 115 KHz suitable for human body energy penetration due to its large skin-depth and lower inductive power attenuation. The complete signal processing is done digitally, external coil and capacitor is used for transceiver interface. The telemetry assists a smart pill swallowed by human being to trigger an actuator for drug delivery, record temperature, or perform diagnostic task inside the body. The smart pill includes 32bit processor, 16 Kbyte memory, temperature sensor, telemetry unit, and additional external peripheries. The complete system is designed, embedded in one SoC, and realized on ASIC with chip-area less than 14 mm<sup>2</sup>.
Aktiver RFID-Sensor
(2008)
Das in Schramberg ansässige Unternehmen Schweizer Electronic, einer der großen europäischen Leiterplattenhersteller, hat sich ein neues Geschäftsfeld als Systemlieferant für mikroelektronische Geräte erschlossen. Gemeinsam mit dem Institut für Angewandte Forschung der Hochschule Offenburg und Siemens hat das Unternehmen einen Datenlogger mit einer ISO 15693 kompatiblen 13,56 MHz RFID-Luftschnittstelle zur Serienreife entwickelt. Die SEAGsens Temperaturmessgeräte aus der Vorserienproduktion haben die ersten Feldtests erfolgreich bestanden. Die Großserienproduktion wird noch in diesem Jahr anlaufen.