Refine
Year of publication
- 2016 (52) (remove)
Document Type
- Article (reviewed) (52) (remove)
Has Fulltext
- no (52)
Is part of the Bibliography
- yes (52) (remove)
Keywords
- Energieversorgung (3)
- Computertomografie (2)
- Durchblutung (2)
- Lichtbogenofen (2)
- Lithium-Ionen-Akkumulator (2)
- Messtechnik (2)
- Radiologie (2)
- Schlafforschung (2)
- Ultraschall (2)
- Wärmeübertragung (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (30)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (15)
- INES - Institut für nachhaltige Energiesysteme (9)
- Fakultät Wirtschaft (W) (6)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (1)
Open Access
- Closed Access (10)
- Open Access (10)
- Closed (3)
Im Rahmen der Cochleaimplantat (CI)-Versorgung werden sowohl intraoperativ als auch postoperativ verschiedene elektrische und elektrophysiologische Diagnostikverfahren eingesetzt, bei denen elektrische Messgrößen vom CI erfasst und elektrophysiologische Messungen bei CI-Patienten durchgeführt werden. Zu den elektrophysiologischen Diagnostikverfahren zählen die Messung der elektrisch evozierten Summenaktionspotenziale des Hörnervs, die Registrierung der elektrisch evozierten auditorischen Hirnstammpotenziale und die Erfassung der elektrisch evozierten auditorischen kortikalen Potenziale. Diese Potenziale widerspiegeln die Erregung des Hörnervs und die Reizverarbeitung in verschiedenen Stationen der aufsteigenden Hörbahn bei intracochleärer elektrischer Stimulation mittels eines CI. Bei den aktuellen CI sind die Beurteilung der Elektrodenlage sowie die Prüfung der Ankopplung des Implantats an den Hörnerv wichtige Anwendungsgebiete der elektrophysiologischen Diagnostikverfahren. Ein weiteres bedeutendes Einsatzfeld stellt die Prüfung der Reizverarbeitung in der Hörbahn dar. Das Hauptanwendungsgebiet dieser Verfahren bildet jedoch die Unterstützung der Anpassung der CI-Sprachprozessoren bei Säuglingen und Kleinkindern auf der Basis elektrophysiologischer Schwellen.
Selective separation of CO2-CH4 mixed gases via magnesium aminoethylphosphonate nanoparticles
(2016)
The existence of acoustic waves with displacements localized at the tip of an isotropic elastic wedge was rigorously proven by Kamotskii, Zavorokhin and Nazarov. This proof, which is based on a variational approach, is extended to rectangular anisotropic wedges. For two high-symmetry configurations of rectangular edges in elastic media with tetragonal symmetry, a criterion is derived that allows identifying the boundary between the regions of existence for wedge modes of even and odd symmetry in regions of parameter space, where even- and odd-symmetry modes do not exist simultaneously. Furthermore, rectangular edges with non-equivalent surfaces are analyzed, and it is shown that at rectangular edges of cubic elastic media with one (110) surface and one (001) surface, a tip-localized guided wave always exists, apart from special cases that are characterized.
Laser pulses focused near the tip of an elastic wedge generate acoustic waves guided at its apex. The shapes of the acoustic wedge wave pulses depend on the energy and the profile of the exciting laser pulse and on the anisotropy of the elastic medium the wedge is made of. Expressions for the acoustic pulse shapes have been derived in terms of the modal displacement fields of wedge waves for laser excitation in the thermo-elastic regime and for excitation via a pressure pulse exerted on the surface. The physical quantity considered is the local inclination of a surface of the wedge, which is measured optically by laser-probe-beam deflection. Experimental results on pulse shapes in the thermo-elastic regime are presented and confirmed by numerical calculations. They pertain to an isotropic sharp-angle wedge with two wedge-wave branches and to a non-reciprocity phenomenon at rectangular silicon edges.
Two closely related series of paddle-wheel-based triazolyl isophthalate MOFs are presented. Thermal and CO2 adsorption studies reveal network flexibility induced by alkyl substituents of the linker. By choice of the substituent, the pore volumes and pore diameters can be adjusted. Fine-tuning of the gate opening pressure and the hysteresis shape is possible by modulating the substitution pattern and by choice of the metal ion.
MITK-OpenIGTLink for combining open-source toolkits in real-time computer-assisted interventions
(2016)
PURPOSE:
Due to rapid developments in the research areas of medical imaging, medical image processing and robotics, computer-assisted interventions (CAI) are becoming an integral part of modern patient care. From a software engineering point of view, these systems are highly complex and research can benefit greatly from reusing software components. This is supported by a number of open-source toolkits for medical imaging and CAI such as the medical imaging interaction toolkit (MITK), the public software library for ultrasound imaging research (PLUS) and 3D Slicer. An independent inter-toolkit communication such as the open image-guided therapy link (OpenIGTLink) can be used to combine the advantages of these toolkits and enable an easier realization of a clinical CAI workflow.
METHODS:
MITK-OpenIGTLink is presented as a network interface within MITK that allows easy to use, asynchronous two-way messaging between MITK and clinical devices or other toolkits. Performance and interoperability tests with MITK-OpenIGTLink were carried out considering the whole CAI workflow from data acquisition over processing to visualization.
RESULTS:
We present how MITK-OpenIGTLink can be applied in different usage scenarios. In performance tests, tracking data were transmitted with a frame rate of up to 1000 Hz and a latency of 2.81 ms. Transmission of images with typical ultrasound (US) and greyscale high-definition (HD) resolutions of [Formula: see text] and [Formula: see text] is possible at up to 512 and 128 Hz, respectively.
CONCLUSION:
With the integration of OpenIGTLink into MITK, this protocol is now supported by all established open-source toolkits in the field. This eases interoperability between MITK and toolkits such as PLUS or 3D Slicer and facilitates cross-toolkit research collaborations. MITK and its submodule MITK-OpenIGTLink are provided open source under a BSD-style licence ( http://mitk.org )
Mit der Messung des Wärme- und Kälteverbrauchs im Labor gelingt es, sowohl thermisch träge als auch agile Flächentemperiersysteme unter praxisnahen, dynamischen Bedingungen messtechnisch zu bewerten. Werden Nutzwärme- und Nutzkältebedarf berechnet und ins Verhältnis zu den gemessenen Verbräuchen gesetzt, können die Aufwandzahlen für die Nutzenübergabe ece für verschiedene Flächentemperiersysteme und in Kombinationen mit anderen Übergabesystemen unter verschiedenen Nutzungsbedingungen und für unterschiedliche Betriebsführungsstrategien bestimmt werden. Damit stehen Aufwandszahlen auf Basis kalorischer Messungen zur Verfügung, die je nach Aufgabenstellung entweder produkt- oder objektbezogen in der Planung komplexer Energiekonzepte verwendet werden können und die tatsächlichen Aufwandszahlen eh, ce für den Heizfall bzw. ec, ce für den Kühlfall genauer als Literaturwerte bzw. projektbezogen beschreiben
Cardiac resynchronization therapy is an established therapy for heart failure patients. The aim of the study was to evaluate electrical left cardiac atrioventricular delay and interventricular desynchronization in sinus rhythm cardiac resynchronization therapy responder and non-responder. Cardiac electrical desynchronization were measured by surface ECG and focused transesophageal bipolar left atrial and left ventricular ECG before implantation of cardiac resynchronization therapy defibrillators. Preoperative electrical cardiac desynchronization was 195.7 ± 46.7 ms left cardiac atrioventricular delay and 74.8 ± 24.5 ms interventricular delay in cardiac resynchronization therapy responder. Cardiac resynchronization therapy responder New York Heart Association class improved during long term biventricular pacing. Transesophageal left cardiac atrioventricular delay and interventricular delay may be additional useful parameters to improve patient selection for cardiac resynchronization therapy.
Die Namen Cormack und Hounsfield sind für den Radiologen zu einem wichtigen Synonym für die Computertomographie (CT) geworden. Der mathematische Wegbereiter für die CT, Johann Radon, kommt in der radiologischen Diskussion und den historischen Rückblicken hingegen oft zu Unrecht zu kurz. Die folgende Kurzübersicht möchte daher dem interessierten Leser die wichtigsten historischen Eckdaten zu dem in vielerlei Hinsicht bewegenden Leben und Wirken dieses großen Mathematikers näherbringen.