Three real-lab trigeneration microgrids are investigated in non-residential environments (educational, office/administrational, companies/production) with a special focus on domain-specific load characteristics. For accurate load forecasting on such a local level, à priori information on scheduled events have been combined with statistical insight from historical load data (capturing information on not explicitly-known consumer behavior). The load forecasts are then used as data input for (predictive) energy management systems that are implemented in the trigeneration microgrids. In real-world applications, these energy management systems must especially be able to carry out a number of safety and maintenance operations on components such as the battery (e.g. gassing) or CHP unit (e.g. regular test runs). Therefore, energy management systems should combine heuristics with advanced predictive optimization methods. Reducing the effort in IT infrastructure the main and safety relevant management process steps are done on site using a Smart & Local Energy Controller (SLEC) assisted by locally measured signals or operator given information as default and external inputs for any advanced optimization. Heuristic aspects for local fine adjustment of energy flows are presented.
Für die solarunterstützte CO2-neutrale Nahwärmeversorgung des Neubaugebiets Hülben in Holzgerlingen wurden Holzpelletskessel mit einer 249m²-großen Solaranlage kombiniert. Im ersten Intensivmessjahr vom 01.03.2007 bis 29.02.2008 wurde eine Gesamt-Wärmeabgabe ins Nahwärmenetz von 920.606 kWh gemessen, wobei der solare Anteil bei 84.033 kWh lag. Es wurden ein Systemnutzungsgrad von 23,8 % und ein solarer Deckungsanteil von 9,5% gemessen. Die vom Lieferanten abgegebene Energiegarantie wurde in der ersten Intensivmessphase nicht erreicht.
The uncertain and time-variant nature of renewable energy results in the need to deal with peaks in the production of energy. One approach is to achieve a load shift and thereby help balancing the grid by using thermally Activated Building Systems (TABS). Control systems currently in place do not exploit the full potential of TABS. This paper reviews how Model Predictive Control can possibly reduce the fluctuations of the demand and supply of (renewable) energy as it enables the TABS to react to the dynamics of weather and its impact on the grid at any time.
The PHOTOPUR project aims to develop a photocatalytic process as a type of AOPs (Advanced Oxidation Processes) for the elimination of plant protection products (PPP) of the cleaning water used to wash sprayers. At INES a PV based energy supply for the photocatalytic cleaning system was developed within the framework of two bachelor theses and assembled as a demonstration unit. Then the system was step by step extended with further process automation features and pushed to a remote operating device. The final system is now available as a mobile unit mounted on a lab table. The latest step was the photocatalytic reactor module which completed the first PHOTOPUR prototype. The system is actually undergoing an intensive testing phase with performance checks at the consortium partners. First results give an overview about the successful operation.
An energy oriented design concept was developed within the research project PHOTOPUR which has the development of a PV powered water cleaning system as main focus. During a wine season Plant Protection Products (PPP) are several times sprayed on plants to protect them of undesired insects and herbs or avoid hazardous fungus
types. A work package of the project partner INES in Offenburg led to a design introducing energy profiling already in the early beginning of a product design. The concept is based on three pillars respecting first the
requirements of the core process making up filtering and cleaning and secondary aspects which run, support, maintain and monitor the system to secure availability and product reliability.
The presented paper shows that the results of the design tools guided the developers to assemble a functional model of the water decontamination unit which was manually tested with its concatenated steps of the water cleaning process.