Refine
Year of publication
Document Type
- Article (reviewed) (43) (remove)
Language
- English (43)
Is part of the Bibliography
- yes (43)
Keywords
- Dünnschichtchromatographie (16)
- HPTLC (5)
- Chromatographie (4)
- Faseroptik (3)
- Belastung (2)
- Densitometrie (2)
- Diode-array detection (2)
- Fluorescence enhancement (2)
- High-performance thin-layer chromatography (2)
- Kubelka-Munk theory (2)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (43) (remove)
Open Access
- Closed Access (22)
- Open Access (7)
- Closed (4)
- Hybrid (2)
- Gold (1)
High performance thin layer chromatography (HPTLC) is a frequently used separation technique which works well for quantification of caffeine and quinine in beverages. Competing separation techniques, e.g. high-performance liquid chromatography (HPLC) or gas chromatography (GC), are not suitable for sugar-containing samples, because these methods need special pretreatment by the analyst. In HPTLC, however, it is possible to separate ‘dirty’ samples without time-consuming pretreatment, because disposable HPTLC plates are used. A convenient method for quantification of caffeine and quinine in beverages, without sample pretreatment, is presented below. The basic theory of in-situ quantification in HPTLC by use of remitted light is introduced and discussed. Several linearization models are discussed.
A home-made diode-array scanner has been used for quantification; this, for the first time, enables simultaneous measurements at different wavelengths. The new scanner also enables fluorescence evaluation without further equipment. Simultaneous recording at different wavelengths improves the accuracy and reliability of HPTLC analysis. These aspects result in substantial improvement of in-situ quantitative densitometric analysis and enable quantification of compounds in beverages.
A new diode-array scanner in combination with a computer-controlled application system meets all the demands of modern HPTLC measurement. Automatic application, simultaneous measurements at different wavelengths, and different linearization models enable appropriate evaluation of all analytical questions. The theory of error propagation recommends quantification at reflectance values smaller than 0.8; this can be verified only by use of diode-array scanning. The same theory also recommends quantification by use of peak height data, because the theory predicts best precision only for peak height evaluation. Diode-array scanning with reflectance monitoring enables appropriate validation in TLC and HPTLC analysis. All these aspects result in substantial improvement of in-situ quantitative densitometric analysis, and simultaneous recording at different wavelengths opens the way for chemometric evaluation, e.g. peak purity monitoring, which improves the accuracy and reliability of HPTLC analysis.
Fluorescence Enhancement of Pyrene Measured by Thin-Layer Chromatography with Diode-Array Detection
(2003)
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography. It offers a simple way of quantifying by measuring the optical density of the separated spots directly on the plate. A new TLC scanner has been developed which is able to measure TLC plates or HPTLC plates, at different wavelengths simultaneously, without destroying the plate surface. The system enables absorbance and fluorescence measurements in one run. Fluorescence measurements are possible without filters or other adjustments.
The measurement of fluorescence from a TLC plate is a versatile means of making TLC analysis more sensitive. Fluorescence measurements with the new scanner are possible without filters or special lamps. Improvement of the signal-to-noise ratio is achieved by wavelength bundling. During plate scanning the scattered light and the fluorescence are both emitted from the surface of the TLC plate and this emitted light provides the desired spectral information from substances on the TLC plate. The measurement of fluorescence spectra and absorbance spectra directly from a TLC plate is based on differential measurement of light emerging from sample-free and sample-containing zones.
The literature recommends dipping TLC plates in viscous liquids to enhance fluorescence. Measurement of the fluorescence and absorbance spectra of pyrene spots reveals the mechanism of enhancement of plate dipping in viscous liquids—blocked contact of the fluorescent molecules with the stationary phase or other sample molecules is responsible for the enhanced fluorescence at lower concentrations.
In conclusion, dipping in TLC analysis is no miracle. It is based on similar mechanisms observable in liquids. The measured TLC spectra are also very similar to liquid spectra and this makes TLC spec-troscopy an important tool in separation analysis.
A new formula is presented for transforming fluorescence measurements in accordance with Kubelka-Munk theory. The fluorescence signals, the absorption signals, and data from a selected reference are combined in one expression. Only diode-array techniques can measure all the required data simultaneously to linearize fluorescence data correctly. To prove the new theory HPTLC quantification of the analgesic flupirtine was performed over the mass range 300 to 5000 ng per spot. The fluorescence calibration curve was linear over the whole range. The transformation of fluorescence measurements into linear mass-dependent data extends the technique of in-situ fluorescence analysis to the high concentration range. It also extends Kubelka-Munk theory from absorption to fluorescence analysis. The results presented also emphasize the importance of Kubelka-Munk theory for in-situ measurements in scattering media, especially in planar chromatography.
Enzyme‐assisted HPTLC method for the simultaneous analysis of inositol phosphates and phosphate
(2023)
Background
The analysis of myo‐inositol phosphates (InsPx) released by phytases during phytic acid degradation is challenging and time‐consuming, particularly in terms of sample preparation, isomer separation, and detection. However, a fast and robust analysis method is crucial when screening for phytases during protein engineering approaches, which result in a large number of samples, to ensure reliable identification of promising novel enzymes or target variants with improved characteristics, for example, pH range, thermal stability, and phosphate release kinetics.
Results
The simultaneous analysis of several InsPx (InsP1‐InsP4 and InsP5 + 6) as well as free phosphate was established on cellulose HPTLC plates using a buffered mobile phase. Inositol phosphates were subsequently stained using a novel enzyme‐assisted staining procedure. Immobilized InsPx were hydrolyzed by a phytase solution of Quantum® Blueliquid 5G followed by a molybdate reagent derivatization. Resulting blue zones were captured by DAD scan. The method shows good repeatability (intra‐day and intra‐lab) with maximum deviations of the Rf value of 0.01. The HPTLC method was applied to three commercially available phytases at two pH levels relevant to the gastrointestinal tract of poultry (pH 5.5 and pH 3.6) to observe their phytate degradation pattern and thus visualize their InsPx fingerprint.
Conclusion
This HPTLC method presents a semi‐high‐throughput analysis for the simultaneous analysis of phytic acid and the resulting lower inositol phosphates after its enzymatic hydrolysis and is also an effective tool to visualize the InsPx fingerprints and possible accumulations of inositol phosphates.
High-performance thin-layer chromatography (HPTLC), as the modern form of TLC (thin-layer chromatography), is suitable for detecting pharmaceutically active compounds over a wide polarity range using the gradient multiple development (GMD) technique. Diode-array detection (DAD) in conjunction with HPTLC can simultaneously acquire ultraviolet‒visible (UV‒VIS) and fluorescence spectra directly from the plate. Visualization as a contour plot helps to identify separated zones. An orange peel extract is used as an example to show how GMD‒DAD‒HPTLC in seven different developments with seven different solvents can provide an overview of the entire sample. More than 50 compounds in the extract can be separated on a 6-cm HPTLC plate. Such separations take place in the biologically inert stationary phase of HPTLC, making it a suitable method for effect-directed analysis (EDA). HPTLC‒EDA can even be performed with living organism, as confirmed by the use of Aliivibrio fischeri bacteria to detect bioluminescence as a measure of toxicity. The combining of gradient multiple development planar chromatography with diode-array detection and effect-directed analysis (GMD‒DAD‒HPTLC‒EDA) in conjunction with specific staining methods and time-of-flight mass spectrometry (TOF‒MS) will be the method of choice to find new chemical structures from plant extracts that can serve as the basic structure for new pharmaceutically active compounds.
Two solvent mixtures for high-performance thin-layer chromatographic (HPTLC) separation of some compounds showing estrogenic activity in the yeast estrogen screen (YES) assay are presented. The new method, planar yeast estrogen screen (pYES) combines the YES assay and a chromatographic separation on silica gel HPTLC plates with the performance of the YES assay. For separation, the analytes were applied bandwise to HPTLC plates (10 × 20 cm) with fluorescent dye (Merck, Germany). The plates were developed in a vertical developing chamber after 30 min of chamber saturation over a separation distance of 70 mm, using cyclohexane‒methyl-ethyl ketone (2:1, V/V) or cyclohexane‒CPME (3:2, V/V) as solvents. Both solvents allow separation of estriol, daidzein, genistein, 17β-estradiol, 17α-ethinyl estradiol, estrone, 4-nonylphenol and bis(2-ethylhexyl) phthalate.
We present a densitometric quantification method for triclosan in toothpaste, separated by high-performance thin-layer chromatography (HPTLC) and using a 48-bit flatbed scanner as the detection system. The sample was band-wise applied to HPTLC plates (10 × 20 cm), with fluorescent dye, Merck, Germany (1.05554). The plates were developed in a vertical developing chamber with 20 min of chamber saturation over 70 mm, using n-heptane–methyl tert-butyl ether–acetic acid (92:8:0.1, V/V) as solvent. The RF value of triclosan is hRF = 22.4, and quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue) after plate staining with 2,6-dichloroquinone-4-chloroimide (Gibbs' reagent). Evaluation of the red channel makes the measurements of triclosan very specific. For linearization, an extended Kubelka–Munk expression was used for data transformation. The range of linearity covers more than two orders of magnitude and is between 91 and 1000 ng. The separation method is inexpensive, fast and reliable.
We present a video-densitometric high-performance thin-layer chromatography (HPTLC) quantification method for patulin in apple juice, developed in a vertical chamber from the starting point to a distance of 50 mm, using MTBE, n-pentane (9 + 5, v/v) as mobile phase. After separation the plate is sprayed with methyl-benzothiazolinone hydrazone hydrochloride monohydrate (MBTH) solution (40 mg in 20 mL methanol) and heated at 105 °C for 15 min. Patulin zones are transformed into yellow spots. The quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of the blue channel makes the measurements very specific. Quantification in fluorescence was also done by use of a 16-bit CCD-camera and UV-366 nm illumination as well as using a HPTLC DAD-scanner. For linearization the extended Kubelka–Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 5 and 800 ng patulin. The extraction of 20 g apple juice and an extract application on plate up to 50 µL allows statistically defined checking the limit of detection (LOD) of 50 ng patulin per track, which is equivalent to 50 µg patulin per kg apple juice.
A Simple and Reliable HPTLC Method for the Quantification of the Intense Sweetener Sucralose®
(2003)
This paper describes a simple and fast thin layer chromatography (TLC) method for the monitoring of the relatively new intense sweetener Sucralose® in various food matrices. The method requires little or no sample preparation to isolate or concentrate the analyte. The Sucralose® extract is separated on amino‐TLC‐plates, and the analyte is derivatized “reagent‐free” by heating the developed plate for 20 min at 190°C. Spots can be measured either in the absorption or fluorescence mode. The method allows the determination of Sucralose® at the levels of interest regarding foreseen European legislation (>50 mg/kg) with excellent repeatability (RSD = 3.4%) and recovery data (95%).