In this paper, we describe the PALM model system 6.0. PALM (formerly an abbreviation for Parallelized Large-eddy Simulation Model and now an independent name) is a Fortran-based code and has been applied for studying a variety of atmospheric and oceanic boundary layers for about 20 years. The model is optimized for use on massively parallel computer architectures. This is a follow-up paper to the PALM 4.0 model description in Maronga et al. (2015). During the last years, PALM has been significantly improved and now offers a variety of new components. In particular, much effort was made to enhance the model with components needed for applications in urban environments, like fully interactive land surface and radiation schemes, chemistry, and an indoor model. This paper serves as an overview paper of the PALM 6.0 model system and we describe its current model core. The individual components for urban applications, case studies, validation runs, and issues with suitable input data are presented and discussed in a series of companion papers in this special issue.
Optimisation based economic despatch of real-world complex energy systems demands reduced order and continuously differentiable component models that can represent their part-load behaviour and dynamic responses. A literature study of existing modelling methods and the necessary characteristics the models should meet for their successful application in model predictive control of a polygeneration system are presented. Deriving from that, a rational modelling procedure using engineering principles and assumptions to develop simplified component models is applied. The models are quantitatively and qualitatively evaluated against experimental data and their efficacy for application in a building automation and control architecture is established.
Cooling towers or recoolers are one of the major consumers of electricity in a HVAC plant. The implementation and analysis of advanced control methods in a practical application and its comparison with conventional controllers is necessary to establish a framework for their feasibility especially in the field of decentralised energy systems. A standard industrial controller, a PID and a model based controller were developed and tested in an experimental set-up using market-ready components. The characteristics of these controllers such as settling time, control difference, and frequency of control actions are compared based on the monitoring data. Modern controllers demonstrated clear advantages in terms of energy savings and higher accuracy and a model based controller was easier to set-up than a PID.
Thermisch angetriebene (Adsorptions-)Kältemaschinen können mit einem verhältnismäßig geringen elektrischen Energieaufwand bzw. mit einer hohen elektrischen Leistungszahl Kälte bereitstel-len. Wird die zum Antrieb erforderliche Wärme aus industrieller Abwärme bereitgestellt, ist diese Kältebereitstellung energetisch effizienter als die Kältebereitstellung über eine Kompressionskäl-temaschine. Wird die Wärme jedoch in Kraft-Wärme-Kopplung bereitgestellt, ist die primärenergetische Bewertung sowohl von mehreren Teilwirkungsgraden als auch den Primärenergiefaktoren für den eingesetzten Brennstoff und die erzeugte bzw. bezogene elektrische Energie abhängig. Eine umfangreiche Messkampagne im Sommer 2018 liefert unter realitätsnahen Randbedingungen in einer Labor umgebung detaillierte Energiekennzahlen für einen typischen Tagesgang des Kältebedarfs. Damit gelingt es, Teilenergiekennwerte für die Planungspraxis abzuleiten und das Gesamtsystem energetisch mit einer konventionellen Kompressionskältemaschine zu vergleichen.
In this article we outline the model development planned within the joint projectModel-based city planningand application in climate change (MOSAIK). The MOSAIK project is funded by the German FederalMinistry of Education and Research (BMBF) within the frameworkUrban Climate Under Change ([UC]2)since 2016. The aim of MOSAIK is to develop a highly-efficient, modern, and high-resolution urban climatemodel that allows to be applied for building-resolving simulations of large cities such as Berlin (Germany).The new urban climate model will be based on the well-established large-eddy simulation code PALM, whichalready has numerous features related to this goal, such as an option for prescribing Cartesian obstacles. Inthis article we will outline those components that will be added or modified in the framework of MOSAIK.Moreover, we will discuss the everlasting issue of acquisition of suitable geographical information as inputdata and the underlying requirements from the model's perspective.
Membrane distillation (MD) is a thermal separation process which possesses a hydrophobic, microporous
membrane as vapor space. A high potential application for MD is the concentration of hypersaline brines, such as
e.g. reverse osmosis retentate or other saline effluents to be concentrated to a near saturation level with a Zero
Liquid Discharge process chain. In order to further commercialize MD for these target applications, adapted MD
module designs are required along with strategies for the mitigation of membrane wetting phenomena. This
work presents the experimental results of pilot operation with an adapted Air Gap Membrane Distillation
(AGMD) module for hypersaline brine concentration within a range of 0–240 g NaCl /kg solution. Key performance
indicators such as flux, GOR and thermal efficiency are analyzed. A new strategy for wetting mitigation
by active draining of the air gap channel by low pressure air blowing is tested and analyzed. Only small reductions
in flux and GOR of 1.2% and 4.1% respectively, are caused by air sparging into the air gap channel.
Wetting phenomena are significantly reduced by avoiding stagnant distillate in the air gap making the air blower
a seemingly worth- while additional system component.
Energy consumption for cooling is growing dramatically. In the last years, electricity peak consumption grew significantly, switching from winter to summer in many EU countries. This is endangering the stability of electricity grids. This article outlines a comprehensive analysis of an office building performances in terms of energy consumption and thermal comfort (in accordance with static – ISO 7730:2005 – and adaptive thermal comfort criteria – EN 15251:2007 –) related to different cooling concepts in six different European climate zones. The work is based on a series of dynamic simulations carried out in the Trnsys 17 environment for a typical office building. The simulation study was accomplished for five cooling technologies: natural ventilation (NV), mechanical night ventilation (MV), fan-coils (FC), suspended ceiling panels (SCP), and concrete core conditioning (CCC) applied in Stockholm, Hamburg, Stuttgart, Milan, Rome, and Palermo. Under this premise, the authors propose a methodology for the evaluation of the cooling concepts taking into account both, thermal comfort and energy consumption.
Since 2003, most European countries established heat health warning systems to alert the population to heat load. Heat health warning systems are based on predicted meteorological conditions outdoors. But the majority of the European population spends a substantial amount of time indoors, and indoor thermal conditions can differ substantially from outdoor conditions. The German Meteorological Service (Deutscher Wetterdienst, DWD) extended the existing heat health warning system (HHWS) with a thermal building simulation model to consider heat load indoors. In this study, the thermal building simulation model is used to simulate a standardized building representing a modern nursing home, because elderly and sick people are most sensitive to heat stress. Different types of natural ventilation were simulated. Based on current and future test reference years, changes in the future heat load indoors were analyzed. Results show differences between the various ventilation options and the possibility to minimize the thermal heat stress during summer by using an appropriate ventilation method. Nighttime ventilation for indoor thermal comfort is most important. A fully opened window at nighttime and the 2-h ventilation in the morning and evening are more sufficient to avoid heat stress than a tilted window at nighttime and the 1-h ventilation in the morning and the evening. Especially the ventilation in the morning seems to be effective to keep the heat load indoors low. Comparing the results for the current and the future test reference years, an increase of heat stress on all ventilation types can be recognized.
Techno-economic comparison of membrane distillation and MVC in a zero liquid discharge application
(2018)
Membrane distillation (MD) is a thermally driven membrane process for the separation of vapour from a liquid stream through a hydrophobic, microporous membrane. However, a commercial breakthrough on a large scale has not been achieved so far. Specific developments on MD technology are required to adapt the technology for applications in which its properties can potentially outshine state of the art technologies such as standard evaporation. In order to drive these developments in a focused manner, firstly it must be shown that MD can be economically attractive in comparison to state of the art systems. Thus, this work presents a technological design and economic analysis for AGMD and v-AGMD for application in a zero liquid discharge (ZLD) process chain and compares it to the costs of mechanical vapour compression (MVC) for the same application. The results show that MD can potentially be ~40% more cost effective than MVC for a system capacity of 100 m3/day feed water, and up to ~75% more cost effective if the MD is driven with free waste heat.
In 35 deutschen und 7 europäischen Büro- und Verwaltungsgebäuden wurden auf Basis von Monitoringkampagnen über mehrere Betriebsjahre Raum- und Außentemperaturwerte in zeitlich hoher Auflösung erfasst und der thermische Raumkomfort im Sommer standardisiert nach der Komfortnorm DIN EN 15251:2007-08 detailliert ausgewertet. Ergänzt wird die Auswertung um Kurzzeitmesskampagnen über zwei sehr warme Wochen im Sommer in unsanierten bzw. teilsanierten Bürogebäuden, errichtet im Zeitraum von 1960 bis 1975. Die untersuchten Gebäude mit ihrem jeweiligen Kühlkonzept lassen sich in sechs Kategorien einteilen: ohne Kühlung, passive, luftgeführte und wassergeführte Kühlung sowie Mixed-mode-Kühlung und Vollklimatisierung. Im Quervergleich aller Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Raumkomfort und thermischen Kühlenergiebezug bewertet. Detaillierte Komfortuntersuchungen nach der Europäischen Komfortnorm DIN EN 15251:2007-08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen für die Planungspraxis und den Gebäudebetrieb ableiten.