Refine
Year of publication
Document Type
- Conference Proceeding (934)
- Article (reviewed) (559)
- Article (unreviewed) (124)
- Master's Thesis (66)
- Part of a Book (65)
- Contribution to a Periodical (58)
- Book (30)
- Bachelor Thesis (29)
- Patent (29)
- Letter to Editor (28)
Conference Type
- Konferenzartikel (734)
- Konferenz-Abstract (134)
- Sonstiges (34)
- Konferenz-Poster (22)
- Konferenzband (12)
Language
- English (1981) (remove)
Keywords
- RoboCup (32)
- Dünnschichtchromatographie (27)
- COVID-19 (23)
- Export (23)
- Machine Learning (19)
- Gamification (17)
- Kommunikation (15)
- Finite-Elemente-Methode (13)
- Government Measures (13)
- TRIZ (13)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (590)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (501)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (373)
- Fakultät Wirtschaft (W) (281)
- INES - Institut für nachhaltige Energiesysteme (167)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (157)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (146)
- Fakultät Medien (M) (ab 22.04.2021) (82)
- IMLA - Institute for Machine Learning and Analytics (72)
- ACI - Affective and Cognitive Institute (58)
Open Access
- Open Access (832)
- Closed Access (666)
- Closed (293)
- Bronze (137)
- Gold (75)
- Diamond (67)
- Hybrid (45)
- Grün (12)
Learning to Walk With Toes
(2020)
This paper explains how a model-free (with respect to the robot model and the behavior to learn) approach can facilitate learning to walk from scratch. It is applied to a simulated Nao robot with toes. Results show an improvement of 30% in speed compared to a model without toes and also compared to our model-based approach, but with less stability.
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Cardiac resynchronization therapy is an established therapy for heart failure patients. The aim of the study was to evaluate electrical left cardiac atrioventricular delay and interventricular desynchronization in sinus rhythm cardiac resynchronization therapy responder and non-responder. Cardiac electrical desynchronization were measured by surface ECG and focused transesophageal bipolar left atrial and left ventricular ECG before implantation of cardiac resynchronization therapy defibrillators. Preoperative electrical cardiac desynchronization was 195.7 ± 46.7 ms left cardiac atrioventricular delay and 74.8 ± 24.5 ms interventricular delay in cardiac resynchronization therapy responder. Cardiac resynchronization therapy responder New York Heart Association class improved during long term biventricular pacing. Transesophageal left cardiac atrioventricular delay and interventricular delay may be additional useful parameters to improve patient selection for cardiac resynchronization therapy.
AV delay (AVD) optimization can improve hemodynamics and avoid nonresponding to cardiac resynchronization therapy (CRT). AVD can be approximated by the sum of the individual implant-related interatrial conduction interval and a mean electromechanical interval of about 50ms. We searched for methods to facilitate automatic, implant-based AV delay optimization. In 25 patients (19m, 6f, age: 65±8yrs.) with Medtronic Insync III Marquis CRT-D series systems and left ventricular electrode at lateral or posterolateral wall, we determined interatrial conduction intervals by telemetric left ventricular tip versus superior vena cava coil electrogram (LVCE). Compared with esophageal measurements, the duration of optimal AV delay by LVCE showed good correlation (k=0.98, p=0.01) with a difference of 1.5±4.9ms, only. Therefore, LVCE is feasible to determine interatrial conduction intervals in order to automate AV delay optimization in CRT-D pacing promising increased accuracy compared to other algorithms.
Legacy industrial communication protocols are proved robust and functional. During the last decades, the industry has invented completely new or advanced versions of the legacy communication solutions. However, even with the high adoption rate of these new solutions, still the majority industry applications run on legacy, mostly fieldbus related technologies. Profibus is one of those technologies that still keep on growing in the market, albeit a slow in market growth in recent years. A retrofit technology that would enable these technologies to connect to the Internet of Things, utilize the ever growing potential of data analysis, predictive maintenance or cloud-based application, while at the same time not changing a running system is fundamental.
Note: In lieu of an abstract, this is an excerpt from the first page.
Recently, we reported the three-dimensional computer-aided design (3D-CAD) reconstruction of the first “Iron Hand” of the famous Franconian knight, Götz von Berlichingen (1480–1562), who lost his right hand by a cannon ball splinter injury in 1504 in the War of the Succession of Landshut [...]