Refine
Year of publication
Document Type
- Article (reviewed) (20)
- Conference Proceeding (10)
- Book (1)
Conference Type
- Konferenzartikel (10)
Language
- English (31) (remove)
Is part of the Bibliography
- yes (31)
Keywords
- Energieeffizienz (2)
- Klimatechnik (2)
- BIPV (1)
- Baustoff (1)
- Bauökologie (1)
- Belüftung (1)
- Bio-based building envelope (1)
- Building energy efficiency (1)
- Building energy model (1)
- Bürohaus (1)
Institute
Open Access
- Open Access (16)
- Closed Access (8)
- Closed (3)
- Diamond (2)
- Gold (2)
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
To improve the building’s energy efficiency many parameters should be assessed considering the building envelope, energy loads, occupation, and HVAC systems. Fenestration is among the most important variables impacting residential building indoor temperatures. So, it is crucial to use the most optimal energy-efficient window glazing in buildings to reduce energy consumption and at the same time provide visual daylight comfort and thermal comfort. Many studies have focused on the improvement of building energy efficiency focusing on the building envelope or the heating, ventilation, and cooling systems. But just a few studies have focused on studying the effect of glazing on building energy consumption. Thus, this paper aims to study the influence of different glazing types on the building’s heating and cooling energy consumption. A real case study building located under a semi-arid climate was used. The building energy model has been conducted using the OpenStudio simulation engine. Building indoor temperature was calibrated using ASHRAE’s statistical indices. Then a comparative analysis was conducted using seven different types of windows including single, double, and triple glazing filled with air and argon. Tripleglazed and double-glazed windows with argon space offer 37% and 32% of annual energy savings. It should be stressed that the methodology developed in this paper could be useful for further studies to improve building energy efficiency using optimal window glazing.
This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.
The variable refrigerant flow system is one of the best heating, ventilation, and air conditioning systems (HVAC) thanks to its ability to provide thermal comfort inside buildings. But, at the same time, these systems are considered one of the most energy-consuming systems in the building sector. Thus, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. Although many researchers have studied the optimization of the building energy performance considering heating or cooling needs, using air handling units, radiant floor heating, and direct expansion valves, few studies have considered the use of multi-objective optimization using only the thermostat setpoints of VRF systems for both cooling and heating needs. Thus, the main aim of this study is to conduct a sensitivity analysis and a multi-objective optimization strategy for a residential building containing a variable refrigerant flow system, to evaluate the effect of the building performance on energy consumption and improve the building energy efficiency. The numerical model was based on the EnergyPlus, jEPlus, and jEPlus+EA simulation engines. The approach used in this paper has allowed us to reach significant quantitative energy saving by varying the cooling and heating setpoints and scheduling scenarios. It should be stressed that this approach could be applied to several HVAC systems to reduce energy-building consumption.
Energy efficiency and hygrothermal performance of hemp clay walls for Moroccan residential buildings
(2023)
Hemp-based building envelopes have gained significant popularity in developed countries, and now the trend of constructing houses with hemp-clay blocks is spreading to developing countries like Morocco. Investigating the hygrothermal behavior of such structures under actual climate conditions is essential for advancing and promoting this sustainable practice. This paper presents an in-depth experimental characterization of a commercial hemp-clay brick that has been exposed to the outdoor environment for four years, in addition to field measurements on a building scale demonstration prototype. Additionally, the study simulates 17 representative cities to assess the hygrothermal performance and energy-saving potential in each of Morocco's six existing climate zones, using the EnergyPlus engine. The experimental campaign's findings demonstrate excellent indoor air temperature and relative humidity regulation within the hemp-clay wall building, leading to satisfactory levels of thermal comfort within hemp-clay wall buildings. This is attributed to the material's good thermal conductivity and excellent moisture buffering capacity (found to be 0.31 W/mK and 2.25 g/m2%RH), respectively). The energy simulation findings also point to significant energy savings, with cooling and heating energy reductions ranging from 27.7% to 47.5% and 33.7% to 79.8%, respectively, as compared to traditional Moroccan buildings.
Given the looming threats of climate change and the rapid worldwide urbanization, it is a necessity to prioritize the transition towards a carbon-free built environment. This research study provides a holistic digital methodology for parametric design of urban residential buildings with regard to the Mediterranean semi-arid climate zone of Morocco in the early design phase. The morphological parameters of the urban residential buildings, namely the buildings’ typology, the distance between buildings, the urban grid’s orientation, and the window-towall ratio, are evaluated in order to identify the key combinations of passive and active solar design strategies that determine the high energy performing configurations, based on the introduced Energy Performance Index (EPI), which is the ratio between solar BIPV production to maximum available installed BIPV capacity and the normalized thermal energy needs. Through an automated processing of 2187 iterations via Grasshopper, we simulate daylight autonomy, indoor thermal comfort and solar rooftop photovoltaic and building integrated photovoltaic (BIPV) energy potential. Then, we analyze the conflicting objectives of energy efficiency measures, active solar design strategies, and indoor visual comfort in the decision-making process that supports our goal of getting closer to net zero urban residential buildings. The digital workflow showed interesting trends in reaching a balanced equilibrium between performance metrics influenced by the contrasting impact of solar exposure on indoor daylight autonomy and thermal energy demand. Furthermore, the study’s findings indicate that it is possible to achieve an annual load match exceeding 66,56 % while simultaneously ensuring an acceptable visual indoor comfort (sDA higher than 0.4). The findings also highlight the important role of the BIPV system in shifting towards the net zero energy goal, by contributing up to 30 % of the overall solar energy output and covering up to 20 % of the yearly self-consumption. Moreover, the energy balance evaluation on an hourly basis indicates that BIPV system notably enhances the daily load cover factor by up to 5.5 %, particularly in the case of slab SN typology, throughout the different seasons. Graphical representations of the yearly, monthly and hourly load matches and the hourly energy balance of the best performing configurations provide a thorough understanding of the potential evolution of the urban energy system over time as a result of the gradual integration of active solar electricity production.
The contribution of the RoofKIT student team to the SDE 21/22 competition is the extension of an existing café in Wuppertal, Germany, to create new functions and living space for the building with simultaneous energetic upgrading. A demonstration unit is built representing a small cut-out of this extension. The developed energy concept was thoroughly simulated by the student team in seminars using Modelica. The system uses mainly solar energy via PVT collectors as the heat source for a brine-water heat pump (space heating and hot water). Energy storage (thermal and electrical) is installed to decouple generation and consumption. Simulation results confirm that carbon neutrality is achieved for the building operation, consuming and generating around 60 kWh/m2a.
A strong heat load in buildings and cities during the summer is not a new phenomenon. However, prolonged heat waves and increasing urbanization are intensifying the heat island effect in our cities; hence, the heat exposure in residential buildings. The thermophysiological load in the interior and exterior environments can be reduced in the medium and long term, through urban planning and building physics measures. In the short term, an increasingly vulnerable population must be effectively informed of an impending heat wave. Building simulation models can be favorably used to evaluate indoor heat stress. This study presents a generic simulation model, developed from monitoring data in urban multi-unit residential buildings during a summer period and using statistical methods. The model determines both the average room temperature and its deviations and, thus, consists of three sub-models: cool, average, and warm building types. The simulation model is based on the same mathematical algorithm, whereas each building type is described by a specific data set, concerning its building physical parameters and user behavior, respectively. The generic building model may be used in urban climate analyses with many individual buildings distributed across the city or in heat–health warning systems, with different building and user types distributed across a region. An urban climate analysis (with weather data from a database) may evaluate local differences in urban and indoor climate, whereas heat–health warning systems (driven by a weather forecast) obtain additional information on indoor heat stress and its expected deviations.
There is a strong interaction between the urban atmospheric canopy layer and the building energy balance. The urban atmospheric conditions affect the heat transfer through exterior walls, the long-wave heat transfer between the building surfaces and the surroundings, the short-wave solar heat gains, and the heat transport by ventilation. Considering also the internal heat gains and the heat capacity of the building structure, the energy demand for heating and cooling and the indoor thermal environment can be calculated based on the urban microclimatic conditions. According to the building energy concept, the energy demand results in an (anthropogenic) waste heat; this is directly transferred to the urban environment. Furthermore, the indoor temperature is re-coupled via the building envelope to the urban environment and affects indirectly the urban microclimate with a temporally lagged and damped temperature fluctuation. We developed a holistic building model for the combined calculation of indoor climate and energy demand based on an analytic solution of Fourier's equation and implemented this model into the PALM model.
It is considered necessary to implement advanced controllers such as model predictive control (MPC) to utilize the technical flexibility of a building polygeneration system to support the rapidly expanding renewable electricity grid. These can handle multiple inputs and outputs, uncertainties in forecast data, and plant constraints, amongst other features. One of the main issues identified in the literature regarding deploying these controllers is the lack of experimental demonstrations using standard components and communication protocols. In this original work, the economic-MPC-based optimal scheduling of a real-world heat pump-based building energy plant is demonstrated, and its performance is evaluated against two conventional controllers. The demonstration includes the steps to integrate an optimization-based supervisory controller into a typical building automation and control system with off-the-shelf HVAC components and usage of state-of-art algorithms to solve a mixed integer quadratic problem. Technological benefits in terms of fewer constraint violations and a hardware-friendly operation with MPC were identified. Additionally, a strong dependency of the economic benefits on the type of load profile, system design and controller parameters was also identified. Future work for the quantification of these benefits, the application of machine learning algorithms, and the study of forecast deviations is also proposed.