Refine
Year of publication
Document Type
- Conference Proceeding (934)
- Article (reviewed) (558)
- Article (unreviewed) (124)
- Part of a Book (65)
- Master's Thesis (63)
- Contribution to a Periodical (58)
- Book (30)
- Bachelor Thesis (29)
- Patent (29)
- Letter to Editor (28)
Conference Type
- Konferenzartikel (734)
- Konferenz-Abstract (134)
- Sonstiges (34)
- Konferenz-Poster (22)
- Konferenzband (12)
Language
- English (1976) (remove)
Keywords
- RoboCup (32)
- Dünnschichtchromatographie (27)
- COVID-19 (23)
- Export (22)
- Machine Learning (19)
- Gamification (17)
- Kommunikation (15)
- Finite-Elemente-Methode (13)
- Government Measures (13)
- TRIZ (13)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (589)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (501)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (373)
- Fakultät Wirtschaft (W) (279)
- INES - Institut für nachhaltige Energiesysteme (167)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (157)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (146)
- Fakultät Medien (M) (ab 22.04.2021) (80)
- IMLA - Institute for Machine Learning and Analytics (71)
- ACI - Affective and Cognitive Institute (58)
Open Access
- Open Access (830)
- Closed Access (666)
- Closed (290)
- Bronze (136)
- Gold (75)
- Diamond (67)
- Hybrid (44)
- Grün (12)
RETIS – Real-Time Sensitive Wireless Communication Solution for Industrial Control Applications
(2020)
Ultra-Reliable Low Latency Communications (URLLC) has been always a vital component of many industrial applications. The paper proposes a new wireless URLLC solution called RETIS, which is suitable for factory automation and fast process control applications, where low latency, low jitter, and high data exchange rates are mandatory. In the paper, we describe the communication protocol as well as the hardware structure of the network nodes for implementing the required functionality. Many techniques enabling fast, reliable wireless transmissions are used – short Transmission Time Interval (TTI), Time-Division Multiple Access (TDMA), MIMO, optional duplicated data transfer, Forward Error Correction (FEC), ACK mechanism. Preliminary tests show that reliable end-to-end latency down to 350 μs and packet exchange rate up to 4 kHz can be reached (using quadruple MIMO and standard IEEE 802.15.4 PHY at 250 kbit/s).
The primary objective of this thesis is to examine the lean accounting transformation, which involves applying lean management principles to the accounting domain. In recent years, various sectors, including manufacturing, healthcare, and services, have experienced success with lean management practices. Nevertheless, the implementation of lean accounting within financial management has not been as extensively explored. This research aims to bridge that gap by scrutinizing the benefits and potential drawbacks of adopting lean accounting practices in business operations.
This research uses a combination of qualitative techniques and an extensive literature review to better understand the present subject matter. By describing the ideas of lean management and standard accounting and highlighting the fundamental distinctions between the two systems, the literature study lays a theoretical framework. The case studies illustrate the benefits of adopting lean accounting processes with real-world examples of firms that have made the transition effectively.
In the quantitative analysis of lean accounting's impact, both financial and operational factors are examined extensively. The results indicate that companies embracing lean accounting practices experience significant improvements in productivity, cost reduction, and decisionmaking quality. By highlighting the potential gains to be made by incorporating lean techniques into accounting procedures, this study adds to the current body of information on lean management. The findings offer practical implications for accounting professionals, business leaders, and policymakers interested in leveraging lean accounting to drive organizational performance improvement. The thesis finishes with suggestions for further study in this area, lean accounting.
Risk-based Cybermaturity Assessment Model - Protecting the company against ransomware attacks
(2023)
Ransomware has become one of the most catastrophic attacks in the previous decade, hurting businesses of all sorts worldwide. So, no organization is safe, and most companies are reviewing their ransomware defensive solutions to avoid business and operational hazards. IT departments are using cybersecurity maturity assessment frameworks like CMMC, C2M2, CMMI, NIST, CIS, CPP, and others to analyze organization security capabilities. In addition to maturity assessment models for the process layer and human pillar, there are much research on the analysis, identification, and defense of cyber threats in product/software layers that propose state-of-the-art approaches.
This motivates a comprehensive ransomware cyber security solution. Then, a crucial question arises: “How companies can measure the security maturity of controls in a specific danger for example for Ransomware attack?” Several studies and frameworks addressed this subject.
Complexity of understanding the ransomware attack, Lack of comprehensive ransomware defense solutions and Lack of cybermaturity assessment model for ransomware defense solutions are different aspects of problem statement in this study. By considering the most important limitations to developing a ransomware defense cybermaturity assessment method, this study developed a cybermaturity assessment methodology and implemented a Toolkit to conduct cyber security self-assessment specifically for ransomware attack to provide a clearer vision for enterprises to analyze the security maturity of controls regardless of industry or size.
BACKGROUND:
While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL.
METHODS:
This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada.
RESULTS:
A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable.
CONCLUSION:
A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users
(2016)
Objective: The present study evaluated whether the poorer baseline performance of cochlear implant (CI) users or the technical and/or physiological properties of CI stimulation are responsible for the absence of masking release. Design: This study measured speech reception thresholds (SRTs) in continuous and modulated noise as a function of signal to noise ratio (SNR). Study sample: A total of 24 subjects participated: 12 normal-hearing (NH) listeners and 12 subjects provided with recent MED-EL CI systems. Results: The mean SRT of CI users in continuous noise was −3.0 ± 1.5 dB SNR (mean ± SEM), while the normal-hearing group reached −5.9 ± 0.8 dB SNR. In modulated noise, the difference across groups increased considerably. For CI users, the mean SRT worsened to −1.4 ± 2.3 dB SNR, while it improved for normal-hearing listeners to −18.9 ± 3.8 dB SNR. Conclusions: The detrimental effect of fluctuating maskers on SRTs in CI users shown by prior studies was confirmed by the current study. Concluding, the absence of masking release is mainly caused by the technical and/or physiological properties of CI stimulation, not just the poorer baseline performance of many CI users compared to normal-hearing subjects. Speech understanding in modulated noise was more robust in CI users who had a relatively large electrical dynamic range.
In bimodal cochlear implant (CI) / hearing aid (HA) users a constant interaural time delay in the order of several milliseconds occurs due to differences in signal processing of the devices. For MED-EL CI systems in combination with different HA types, we have quantified the respective device delay mismatch (Zirn et al. 2015). In the current study, we investigate the effect of the device delay mismatch in simulated and actual bimodal listeners on sound localization accuracy.
To deal with the device delay mismatch in actual bimodal listeners we delayed the CI stimulation according to the measured HA processing delay and two other values. With all delay values highly significant improvements of the rms error in the localization task were observed compared to the test without the delay. The results help to narrow down the optimal patient-specific delay value.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPDs is highly desirable. Outcomes of a previous study (Zirn, Arndt et al. 2016) revealed that a subset of BiCI users showed improved IPD detection thresholds with the fine structure processing strategy FS4 compared to the constant rate strategy HDCIS using narrowband stimuli. In contrast, little differences between the coding strategies were found for broadband stimuli with regard to binaural speech intelligibility level differences (BILD) as an estimate of binaural unmasking. Compared to normalhearing listeners (7.5 ± 1.2 dB) BILD were small in BiCI users (around 0.5 dB with both coding strategies).
In the present work, we investigated the influence of binaural fitting parameters on BILD. In our cohort of BiCI users many were implanted with electrode arrays differing in length left versus right. Because this length difference typically corresponded to the distance of two electrode contacts the first modification of bilateral fitting was a tonotopic adjustment by deactivation of the most apical electrode contact on the side with the deeper inserted array (tonotopic approach).
The second modification was the isolation of the residual, most apical electrode contacts by deactivation of the basally adjacent electrode contact on each side (tonotopic sparse approach). Applying these modifications, BILD improved by up to 1.5 dB.
The ability to detect a signal masked by noise is improved in normal-hearing (NH) listeners when interaural phase differences (IPD) between the ear signals exist either in the masker or the signal. We determined the impact of different coding strategies in bilaterally implanted cochlear implant (BiCI) users with and without fine-structure coding (FSC) on masking level differences. First, binaural intelligibility level differences (BILD) were determined in NH listeners and BiCI users using their clinical speech processors. NH subjects (n=8) showed a significant mean BILD of 7.5 dB. In contrast, BiCI users (n=9) without FSC as well as with FSC revealed a barely significant mean BILD (0.4 dB respectively 0.6 dB). Second, IPD thresholds were measured in BiCI users using either their speech processors with FS4 or direct stimulation with FSC. With the latter approach, synchronized stimulation providing an interaural accuracy of stimulation timing of 1.67 µs was realized on pitch matched electrode pairs. The resulting individual IPD threshold was lower in most of the subjects with direct stimulation than with their speech processors. These outcomes indicate that some BiCI users can benefit from increased temporal precision of interaural FSC and adjusted interaural frequency-place mapping presumably resulting in improved BILD.