Refine
Year of publication
Document Type
Conference Type
- Konferenzartikel (2)
- Konferenz-Abstract (1)
Language
- English (27) (remove)
Keywords
- Dünnschichtchromatographie (27) (remove)
Institute
Open Access
- Closed Access (18)
- Open Access (4)
A systematic toxicological analysis procedure using high-performance thin layer chromatography in combination with fibre optical scanning densitometry for identification of drugs in biological samples is presented. Two examples illustrate the practicability of the technique. First, the identification of a multiple intake of analgesics: codeine, propyphenazone, tramadol, flupirtine and lidocaine, and second, the detection of the sedative diphenhydramine. In both cases, authentic urine specimens were used. The identifications were carried out by an automatic measurement and computer-based comparison of in situ UV spectra with data from a compiled library of reference spectra using the cross-correlation function. The technique allowed a parallel recording of chromatograms and in situ UV spectra in the range of 197–612 nm. Unlike the conventional densitometry, a dependency of UV spectra by concentration of substance in a range of 250–1000 ng/spot was not observed.
The objective of this thesis is the quantification and qualification of neonicotinoid insecticides using thin-layer chromatography (TLC). Neonicotinoids are a relatively new form of pesticides, which have been proven to be extremely lethal to the honey bee, Apis mellifera. In this paper six forms of neonicotinoid insecticides (i.e. Acetamiprid, Thiacloprid, Imidacloprid, Clothianidin, Thaimethoxam, and Nitenpyram) are analysed. The initial steps are to first find a suitable mobile phase eluent, followed by the search for a reagent causing a luminescence effect of the neonicotinoids on a TLC plate. Subsequently, a calibration method is then used to find the detection limit of this TLC experiment. The aim is, therefore, to achieve a standard method of quantifying and qualifying neonicotinoids via TLC. Whilst a suitable mobile phase has been established, an optimal fluorescent reagent has yet to be found and more research on the subject must be carried out.
A diode array HPTLC method for dequalinium chloride in pharmaceutical preparations is presented. For separation a Nano TLC silica gel plate (Merck) is used with the mobile phase methanol-7.8% aqueous NH(4)(+)CH(3)COO(-) (17:3, v/v) over a distance of 6 cm. Dequalinium chloride shows an R(F) value of 0.58. Pure dequalinium chloride is measured in the wavelength range from 200 to 500 nm and shows several by-products, contour plot visualized in absorption, fluorescence and using the Kubelka-Munk transformation. Scanning of a single track in absorption and fluorescence measuring 600 spectra in the range from 200 to 1100 nm takes 30s. As a sample pre-treatment of an ointment it is simply dissolved in methanol and can be quantified in absorption from 315 to 340 nm. The same separation can also be quantified using fluorescence spectrometry in the range from 355 to 370 nm. A new staining method for dequalinium chloride, using sodium tetraphenyl borate/HCl in water allows a fluorescence quantification in the range from 445 to 485 nm. The linearity range of absorption and fluorescence measurements is from 10 to 2000 ng. Sugar-containing preparations like liquids or lozenges with a reduced sample pre-treatment can be reliably quantified only in fluorescence. The total for the quantification of an ointment sample (measuring four standards and five samples), including all sample pre-treatment steps takes less than 45 min!
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
Limits of quantification of some neonicotinoid insecticides measured by thin-layer chromatography
(2012)
A simple method to quantify the neonicotinoid insecticides nitenpyram, thiamethoxam, acetamiprid, imidacloprid, thiacloprid and clothianidin directly on an HPTLC-plate is presented. As stationary phase silica gel 60 RP-18WF254 s plates were used and a mixture of methyl-t-butyl ether, 2-butanone, NH3 (25%) (5 + 2+0.1, v/v) was used as solvent. All neonicotinoid insecticides show light absorptions below 300 nm. The calculated limits of quantification (LOQ) by UV-detection are in the range from 12 ng to 26 ng on plate depending on the different insecticides.Nitenpyram can be stained using fast blue salt B, forming red zones. The observed LOQ is 25 ng on plate. Acetamiprid can be specifically stained using phenylglyoxylic acid forming a yellow/green fluorescent compound. The LOQ is 52 ng per spot.The compounds thiamethoxam, acetamiprid, thiacloprid and clothianidin can be transformed into blue fluorescing zones, using a relatively new staining solution. This consists of tetraphenylborate and HCl. This is the first publication mentioning that neonicotinoids undergo this reaction. The calculated limits of quantification are in the range from 10 ng to 27 ng on plate.A simple pre-treatment procedure using an acetonitrile extraction and a Chromabond SiOH clean up procedure leads to overall LOQs for bee samples of 48 to 108 µg/Kg. The method can be used to measure neonicotinoid contaminations of bees.
We present a two dimensional (2D) planar chromatographic separation of estrogenic active compounds on RP-18 (Merck, 1.05559) and silica gel (Merck, 1.05721) phase. A mixture of 13 substances was separated using a solvent mix consisting of methanol–acetonitrile–water (2 + 2 + 1, v/v/v) on RP-18 phase in the first direction and cyclohexane–butylacetate–methanol (8 + 6 + 1, v/v/v) in the second direction on silica gel plate. Both developments were carried out over a distance of 70 mm. We used the grafted method to combine both plates in a 2D-separation. This 2D-separation method can be used to quantify 17α-ethinylestradiol (EE2) in an effect-directed analysis using the yeast strain Saccharomyces cerevisiae BJ3505. The test strain (according to McDonnell) contains the estrogen receptor. Its activation by estrogen active compounds is measured by inducting the reporter gene lacZ that encodes the enzyme ß-galactosidase. This enzyme activity is determined on plate by using the fluorescent substrate MUG (4-methylumbelliferyl ß-D-galactopyranoside).