Refine
Year of publication
Document Type
- Article (reviewed) (558) (remove)
Language
- English (558) (remove)
Keywords
- Dünnschichtchromatographie (17)
- Adsorption (10)
- Metallorganisches Netzwerk (9)
- Lithiumbatterie (8)
- Plastizität (8)
- 3D printing (7)
- Energieversorgung (6)
- Ermüdung (6)
- Finite-Elemente-Methode (6)
- Intelligentes Stromnetz (6)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (257)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (112)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (99)
- INES - Institut für nachhaltige Energiesysteme (97)
- Fakultät Wirtschaft (W) (60)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (25)
- IfTI - Institute for Trade and Innovation (13)
- POIM - Peter Osypka Institute of Medical Engineering (13)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (12)
- Fakultät Medien (M) (ab 22.04.2021) (11)
Open Access
- Open Access (250)
- Closed Access (182)
- Gold (67)
- Closed (43)
- Hybrid (20)
- Diamond (14)
- Bronze (3)
- Grün (1)
Soot particles emitted from a light duty (LD) Volkswagen diesel engine running at different operating points (speed and torque levels) are analyzed for mean size determination using a laser‐based three Wavelength Extinction Method (3‐WEM). For this reason, collected soot samples are suspended using an appropriate sample preparation technique with optimized conditions of sonication as it revealed its effect on the soot mean particle size measured by 3‐WEM.
An online Scanning Mobility Particle Analyzer (SMPS) is also used to measure soot emission at identical engine operating points. Size values obtained from SMPS are lower than those of suspended soot samples obtained from 3‐WEM. The size discrepancies are mainly related to the required sample preparation procedure employed for 3‐WEM measurements. The engine operating points affect, differently, the size measurements obtained from SMPS and 3‐WEM.
Sedimentation Field‐Flow Fractionation (SdFFF) is used for density determination of soot samples based on size measurements of fractions collected at peak maxima of fractograms using the off‐line hyphenation with 3‐WEM. It is assumed that a size dependent separation of soot particles occurred with a uniform particle density over the whole size distribution. An average density value is used for the conversion of soot fractograms to size distributions. Discrepancies are also found with size distribution profiles obtained from SMPS for the same engine operating points, due to the sample preparation procedure employed for SdFFF measurements.
Design of next-generation cdma using orthogonal complementary codes and offset stacked spreading
(2007)
This article presents an innovative code-division multiple access system architecture that is based on orthogonal complementary spreading codes and time-frequency domain spreading. The architecture has several advantages compared to conventional CDMA systems. Specifically, it offers multiple-access-interference-free operation in AWGN channels, reduces co-channel interference significantly, and has the potential for higher capacity and spectral efficiency than conventional CDMA systems. This is accomplished by using an "offset stacked" spreading modulation technique followed by quadrature amplitude modulation, which optimizes performance in a fading environment. This new spreading modulation scheme also simplifies the rate matching algorithms relevant for multimedia services and IP-based applications.
Lattice vibrations and electronic transitions in the rare-earth metals: Praseodymium under pressure
(2004)
Praseodymium was investigated by Raman spectroscopy under pressure. A negative pressure shift of the E2g mode is observed in the dhcp phase, which indicates that the initial structural sequence hcp→Sm−type→dhcp→fcc as a whole in the regular lanthanides is associated with a softening of this mode. The pressure response of the phonon modes, observed in the monoclinic and α-uranium phases, where 4f bonding becomes important, is characteristic for anisotropic bonding properties.
Experimental and theoretical investigations of the time of equalization of the concentration of an impurity in a rectangular flow‐type chamber have been carried out. It has been shown that the process of equalization of the concentration with time is exponential in character. The characteristic equalization time has been computed using the theory of turbulent diffusion. Theoretical results describe experimental regularities with an accuracy of about 10%. The value of the coefficient of turbulent diffusion for different configurations of flows in the chamber has been obtained from a comparison of experimental and calculated results.
The structure of the separation bubble that appears in the secondary meridional flow between two coaxially rotating spheres at low and finite Reynolds number (Re) is considered. The low Re analytical study was motivated by recognizing some errors in the analytical work on this problem by Arunachalam and Majhi (1987, Q. Jl Mech. Appl. Math., 40, 47) whilst the finite Re experimental study was motivated by the desire to observe the separation bubble in the laboratory. Though the finite Re experiments were performed in a confined apparatus, they exhibit the qualitative features of the low Re theoretical predictions for the axisymmetric separation bubble that encloses two toroidal vortices symmetrically disposed above and below the mid‐plane of sphere separation, but strong effects of confinement are apparent. The flows observed include (i) a wall‐attached bubble symmetric about the mid‐plane at low Re, (ii) symmetric free‐standing bubbles at moderate Re, and (iii) an asymmetric bubble with flow separating from one sphere and attaching to the support shaft between the spheres at sufficiently high Re.
The free convection in a vertical gap is generalized to realize new analytical solutions of the Boussinesq-equations. The steady and time-dependent solutions for the temperature and velocity distribution are discussed in detail depending on the mass flux in vertical direction. The range of existence for flows with and without back flow is obtained. The transient behaviour of the solutions during the time-dependent development displays interesting physical behaviour.
The use of a TLC scanner can be regarded as a key step in high performance thin layer chromatography (HPTLC). Densitometric measurements transform the substance distribution on a TLC plate into digital computer data. Systems that allow quantitative measurements have been available for many years for either fluorescence or ultraviolet absorption measurements, while lately the reflection analysis mode for both types is the most common application. New scanning approaches are designed to aid the analyst who has common demands for TLC-densitometry without using special data, such as scanned images. Two examples that have been developed lately in the laboratories of the authors are described in this paper. These approaches were developed on the basis of current needs for analysts who employ TLC as a tool in research, as well as in routine analysis. One approach is aimed to support analysts in economically disadvantaged areas, where cost intensive apparatus is unsuitable but trace analysis by simple means is required. The other system, allows the spectral determination of chromatographic spots on TLC plates covering the ultraviolet and visible range, thus, revealing highly desired information for the analyst.
The aim of this study was to develop a biomechanically validated finite element model to predict the biomechanical behaviour of the human lumbar spine in compression.
For validation of the finite element model, an in vitro study was performed: Twelve human lumbar cadaveric spinal segments (six segments L2/3 and six segments L4/5) were loaded in axial compression using 600 N in the intact state and following surgical treatment using two different internal stabilisation devices. Range of motion was measured and used to calculate stiffness.
A finite element model of a human spinal segment L3/4 was loaded with the same force in intact and surgically altered state, corresponding to the situation of biomechanical in vitro study.
The results of the cadaver biomechanical and finite element analysis were compared. As they were close together, the finite element model was used to predict: (1) load-sharing within human lumbar spine in compression, (2) load-sharing within osteoporotic human lumbar spine in compression and (3) the stabilising potential of the different spinal implants with respect to bone mineral density.
A finite element model as described here may be used to predict the biomechanical behaviour of the spine. Moreover, the influence of different spinal stabilisation systems may be predicted.
A systematic toxicological analysis procedure using high-performance thin layer chromatography in combination with fibre optical scanning densitometry for identification of drugs in biological samples is presented. Two examples illustrate the practicability of the technique. First, the identification of a multiple intake of analgesics: codeine, propyphenazone, tramadol, flupirtine and lidocaine, and second, the detection of the sedative diphenhydramine. In both cases, authentic urine specimens were used. The identifications were carried out by an automatic measurement and computer-based comparison of in situ UV spectra with data from a compiled library of reference spectra using the cross-correlation function. The technique allowed a parallel recording of chromatograms and in situ UV spectra in the range of 197–612 nm. Unlike the conventional densitometry, a dependency of UV spectra by concentration of substance in a range of 250–1000 ng/spot was not observed.
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography (TLC). It is a simple means of quantification by measurement of the optical density of the separated spots directly on the plate. A new scanner has been developed which is capable of measuring TLC or HPTLC (high-performance thin-layer chromatography) plates simultaneously at different wavelengths without damaging the plate surface. Fiber optics and special fiber interfaces are used in combination with a diode-array detector. With this new scanner sophisticated plate evaluation is now possible, which enables use of chemometric methods in HPTLC. Different regression models have been introduced which enable appropriate evaluation of all analytical questions. Fluorescent measurements are possible without filters or special lamps and signal-to-noise ratios can be improved by wavelength bundling. Because of the richly structured spectra obtained from PAH, diode-array HPTLC enables quantification of all 16 EPA PAH on one track. Although the separation is incomplete all 16 compounds can be quantified by use of suitable wavelengths. All these aspects are enable substantial improvement of in-situ quantitative densitometric analysis.