Refine
Year of publication
- 2013 (93) (remove)
Document Type
- Conference Proceeding (42)
- Article (reviewed) (24)
- Article (unreviewed) (17)
- Part of a Book (3)
- Book (2)
- Contribution to a Periodical (2)
- Patent (2)
- Letter to Editor (1)
Conference Type
- Konferenzartikel (33)
- Konferenz-Abstract (7)
- Sonstiges (2)
Language
- English (93) (remove)
Keywords
- Kommunikation (6)
- Dünnschichtchromatographie (4)
- Biogas (3)
- Energieversorgung (3)
- Hochtemperaturbrennstoffzelle (3)
- Lithiumbatterie (3)
- Optik (3)
- Sicherheit (3)
- Spektroskopie (3)
- Aufzeichnung (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (61)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (23)
- INES - Institut für nachhaltige Energiesysteme (13)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (8)
- IUAS - Institute for Unmanned Aerial Systems (8)
- Fakultät Wirtschaft (W) (5)
- POIM - Peter Osypka Institute of Medical Engineering (1)
Open Access
- Closed Access (35)
- Open Access (28)
- Bronze (5)
- Closed (1)
Energy consumption for cooling is growing dramatically. In the last years, electricity peak consumption grew significantly, switching from winter to summer in many EU countries. This is endangering the stability of electricity grids. This article outlines a comprehensive analysis of an office building performances in terms of energy consumption and thermal comfort (in accordance with static – ISO 7730:2005 – and adaptive thermal comfort criteria – EN 15251:2007 –) related to different cooling concepts in six different European climate zones. The work is based on a series of dynamic simulations carried out in the Trnsys 17 environment for a typical office building. The simulation study was accomplished for five cooling technologies: natural ventilation (NV), mechanical night ventilation (MV), fan-coils (FC), suspended ceiling panels (SCP), and concrete core conditioning (CCC) applied in Stockholm, Hamburg, Stuttgart, Milan, Rome, and Palermo. Under this premise, the authors propose a methodology for the evaluation of the cooling concepts taking into account both, thermal comfort and energy consumption.
The energy supply of Offenburg University of Applied Sciences (HS OG) was changed from separate generation to trigeneration in 2007/2008. Trigeneration was installed for supplying heat, cooling and electrical power at HS OG. In this paper, trigeneration process and its modes of operation along with the layout of the energy facility at HS OG were described. Special emphasis was given to the operation schemes and control strategies of the operation modes: winter mode, transition mode and summer mode. The components used in the energy facility were also outlined. Monitoring and data analysis of the energy system was carried out after the commissioning of trigeneration in the period from 2008 to 2011. Thus, valuable performance data was obtained.
The paper proposes a system architecture for charging infrastructure that serves the requirements of future fleets of shared-use electric vehicles in urban scenarios. The focus of the development is on the interfaces to central stakeholders such as mobility service providers, distribution network operators and utilities. The main concept of the proposed system is the adherence to a stringent resource-oriented design approach, following the design principles of the Representational State Transfer (REST) architectural software style for distributed systems. This design approach is used from the cloud-based services down to the implementation of the charging infrastructure's control algorithms. Focusing on the resources of the various entities simplifies the implementation of their interactions, compared to the explicit declaration of services that are available. The system design ensures that the charging infrastructure is open to all users and generates a benefit beyond basic charging operations. Integration in emerging smart markets is done via open web-based interfaces. These allow for the generation of an added value of concrete services for shared-use electric mobility. A link to the field of grid operation is proposed using the ISO/IEC 61850 telecontrol standard. The smart meter capabilities of the charging stations can be used to gain additional information on the current state of the distribution grid. As an exemplary service a load management service for a fleet of shared-use electric vehicles is going to be implemented.
Efficient, low-cost, secure and reliable communication solutions are a major stepping stone for smart metering and smart grid applications. This especially holds true for the so called primary communication or local metrological network (LMN) between a local meter or actuator and a data collector or gateway, where the highest requirements with regard to cost, bandwidth, and energy efficiency have to be taken into consideration. Multiple developments and field tests are going on in this field, however, energy autarkic devices are hardly found, yet.
The design of control systems of concentrator photovoltaic power plants will be more challenging in the future. Reasons are cost pressure, the increasing size of power plants, and new applications for operation, monitoring and maintenance required by grid operators, manufacturers and plant operators. Concepts and products for fixed-mounted photovoltaic can only partly be adapted since control systems for concentrator photovoltaic are considerable more complex due to the required high accurate sun-tracking. In order to assure reliable operation during a lifetime of more than 20 years, robustness of the control system is one crucial design criteria. This work considers common engineering technics for robustness, safety and security. Potential failures of the control system are identified and their effects are analyzed. Different attack scenarios are investigated. Outcomes are design criteria that encounter both: failures of system components and malicious attacks on the control system of future concentrator photovoltaic power plants. Such design criteria are a transparent state management through all system layers, self-tests and update capabilities for security concerns. The findings enable future research to develop a more robust and secure control system for concentrator photovoltaics when implementing new functionalities in the next generation.
Automatic Meter Reading (AMR) is a major enabler for the upcoming smart grid. Potentially, it will be one of the first really large-scale M2M-communication solutions for sensor applications.
To date, the definition of the standardized communication stacks for Local Metrological Network (LMN) in AMR is still ongoing. This holds true both for ZigBee Smart Energy Profile and for Wireless M-Bus according to EN 13757. During this process, there is the necessity for flexible, albeit optimized solutions, which support the different existing and upcoming versions of the communication protocols. In the case of Wireless M-Bus, the major contender for European and possibly Asian installations, this is valid not only for the different operation modes (C-, N-, P-, Q-, R-, S-, and T-modes), which work in different frequencies (i.e. 868 MHz, 433 MHz, and 169 MHz) but also for the application layer, where additional bodies, like EN137575, Open Metering System (OMS) Group, or national bodies follow their approaches.
This contribution describes requirements, design techniques and experiences from the development of highly efficient Wireless M-Bus protocol stacks with support of good flexibility and portability between microcontroller platforms and RF-transceivers. The presented approach is not limited to the use of modern software engineering design processes, as such, but also includes essential additional features like testing or simulation, as well as tools for commissioning and monitoring.