Refine
Year of publication
Document Type
- Article (reviewed) (41)
- Article (unreviewed) (16)
- Conference Proceeding (9)
- Patent (9)
- Part of a Book (4)
- Book (2)
- Contribution to a Periodical (2)
Conference Type
- Konferenzartikel (8)
- Konferenz-Abstract (1)
Has Fulltext
- no (83) (remove)
Is part of the Bibliography
- yes (83)
Keywords
- Dünnschichtchromatographie (25)
- Chromatographie (5)
- Faseroptik (5)
- HPTLC (5)
- Analyse (4)
- Densitometrie (3)
- Diode-array detection (3)
- Feuchtigkeit (3)
- Scanner (3)
- TLC (3)
Institute
Open Access
- Closed Access (34)
- Closed (14)
- Open Access (10)
- Hybrid (2)
A systematic toxicological analysis procedure using high-performance thin layer chromatography in combination with fibre optical scanning densitometry for identification of drugs in biological samples is presented. Two examples illustrate the practicability of the technique. First, the identification of a multiple intake of analgesics: codeine, propyphenazone, tramadol, flupirtine and lidocaine, and second, the detection of the sedative diphenhydramine. In both cases, authentic urine specimens were used. The identifications were carried out by an automatic measurement and computer-based comparison of in situ UV spectra with data from a compiled library of reference spectra using the cross-correlation function. The technique allowed a parallel recording of chromatograms and in situ UV spectra in the range of 197–612 nm. Unlike the conventional densitometry, a dependency of UV spectra by concentration of substance in a range of 250–1000 ng/spot was not observed.
In the present study, in vitro toxicity as well as biopersistence and photopersistence of four artificial sweeteners (acesulfame, cyclamate, saccharine, and sucralose) and five antibiotics (levofloxacin, lincomycin, linezolid, marbofloxacin, and sarafloxacin) and of their phototransformation products (PTPs) were investigated. Furthermore, antibiotic activity was evaluated after UV irradiation and after exposure to inocula of a sewage treatment plant. The study reveals that most of the tested compounds and their PTPs were neither readily nor inherently biodegradable in the Organisation for Economic Co-operation and Development (OECD)-biodegradability tests. The study further demonstrates that PTPs are formed upon irradiation with an Hg lamp (UV light) and, to a lesser extent, upon irradiation with a Xe lamp (mimics sunlight). Comparing the nonirradiated with the corresponding irradiated solutions, a higher chronic toxicity against bacteria was found for the irradiated solutions of linezolid. Neither cytotoxicity nor genotoxicity was found in human cervical (HeLa) and liver (Hep-G2) cells for any of the investigated compounds or their PTPs. Antimicrobial activity of the tested fluoroquinolones was reduced after UV treatment, but it was not reduced after a 28-day exposure to inocula of a sewage treatment plant. This comparative study shows that PTPs can be formed as a result of UV treatment. The study further demonstrated that UV irradiation can be effective in reducing the antimicrobial activity of antibiotics, and consequently may help to reduce antimicrobial resistance in wastewaters. Nevertheless, the study also highlights that some PTPs may exhibit a higher ecotoxicity than the respective parent compounds. Consequently, UV treatment does not transform all micropollutants into harmless compounds and may not be a large-scale effluent treatment option.
HPTLC on amino plates, with simple heating of the plates for derivatization, has been used for quantification of glucosamine in nutritional supplements. On heating the plate glucosamine reacts to form a compound which strongly absorbs light between 305 and 330 nm, with weak fluorescence. The reaction product can be detected sensitively either by absorption of light or by fluorescence detection. The detection limit in absorption mode is approximately 25 ng per spot. In fluorescence mode a detection limit of 15 ng is achievable. A calibration plot for absorption detection is linear in the range 25 to 4000 ng glucosamine. The derivative formed from glucosamine by heating is stable for months, and the relative standard deviation is 1.64% for 600 ng glucosamine. The amounts of glucosamine found in nutritional supplements were in agreement with the label declarations.
In thin-layer chromatography, fiber-bundle arrays have been introduced for spectral absorption measurements in the UV-region. Using all-silica fiber bundles, the exciting light will be detected after re-emission on the plate with a fiberoptic spectrometer. In addition, fluorescence light can be detected which will be masked by the re-emitted light. Therefore, it is helpful to separate the absorption and fluorescence on the TLC-plate. A modified three-array assembly has been developed: using one array for detection, the two others are used for excitation with broadband band deuterium-light and with UV-LEDs adjusted to the substances under test. As an example, the quantification of glucosamine in nutritional supplements or spinach leaf extract will be described. Using simply heating of the amino-plate for derivation, the reaction product of Glucosamine can be detected sensitively either by light absorption or by fluorescence, using the new fiber-optic assembly. In addition, the properties of the new 3-row fiber-optic array and the commercially available UV-LEDs will be shown, in the interesting wavelength region for excitation of fluorescence, from 260 nm to 360 nm. The squint angle having an influence on coupling efficiency and spatial resolution will be measured with the inverse farfield method. Some properties of UV-LEDs for analytical applications will be described and discussed, too.
Thin-layer chromatography is a rapid and reliable working method for quantification of mycotoxins which is suitable for checking EC legislation aflatoxin limits for dried figs without an RP-18 pre-column cleaning step. We describe normal-phase chromatography on silica gel plates with 2.4:0.05:0.1:0.05 ( v/v ) methyl t -butyl ether-water-methanol-cyclohexane as mobile phase and reversed-phase chromatography on RP-18 plates with methanol-4% aqueous ZnSO 4 solution-ethyl methyl ketone 15:15:3 ( v/v ) as mobile phase. Sample pretreatment was by modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) extraction with tetrahydrofuran or acetone. NaCl was used as QuEChERS salt. Response was a linear function of amount chromatographed in the ranges 3 to 100 pg per zone for aflatoxins B 2 and G 2 , 10 to 350 pg per zone for the aflatoxins B 1 and G 1 , and 0.25 to 2.5 ng per zone for ochratoxin A. Quantification limits for the aflatoxins were between 13 and 35 pg per zone (equivalent to 1.5 and 2.4 ppb, taking the pre-treatment procedure into account). Ochratoxin A was detectable with a limit of quantification of 970 pg per zone, corresponding to 56 ppb in the sample. Normal phase and RP-18 separations work rapidly, reliably, and at low cost. They are also suitable for checking the content of the mycotoxins patulin, penicillic acid, zearalenone, and deoxynivalenol.
Previous studies of the hyphenation of gas chromatographic separation and spectrophotometric detection in the ultraviolet wavelength range between 168 and 330 nm showed a high potential for applications where the analysis of complex samples is required. Within this paper the development of a state-of-the-art detection system for compounds in the vapour phase is described, offering an improved behaviour compared to previous systems: Dependent on the requirements of established detection systems hyphenated with gas chromatography, the main components of the system have to be designed for optimum performance and reliability of the spectrophotometric detector: A deuterium lamp as a broadband light source has been selected for improved stability in the measurements. A new-type absorption cell based on fiber-optics has been developed considering the dynamic necessary to compete with existing techniques. In addition, the influence of the volume of the cell on the chromatogram needs to be analyzed. Tests for determining the performance of the absorption cell in terms of chemical and thermal influences have been carried out. A new spectrophotometer with adequate spectral resolution in the wavelength range, offering improved stability and dynamic for an efficient use in this application was developed. Furthermore, the influence of each component on the performance, reliability and stability of the sensor system will be discussed. An overview and outlook over the potential applications in the environmental, scientific and medical field will be given.
The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.