Refine
Year of publication
- 2015 (61) (remove)
Document Type
- Article (reviewed) (30)
- Conference Proceeding (14)
- Patent (6)
- Book (4)
- Part of a Book (4)
- Bachelor Thesis (1)
- Master's Thesis (1)
- Article (unreviewed) (1)
Conference Type
- Konferenzartikel (11)
- Konferenz-Abstract (1)
- Konferenz-Poster (1)
- Sonstiges (1)
Language
- English (43)
- German (17)
- Other language (1)
Keywords
- Bauteil (3)
- Dünnschichtchromatographie (3)
- Finite-Elemente-Methode (3)
- Mikrostruktur (3)
- Polymere (3)
- Strömungsmechanik (3)
- Aktivierung (2)
- Alexander von Humboldt (2)
- Brennstoffzelle (2)
- Durchfluss (2)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (61) (remove)
Open Access
- Closed Access (25)
- Open Access (17)
- Bronze (6)
- Closed (1)
- Diamond (1)
We present a 3D simulation approach utilising the diffuse interface representation of the phase-field method combined with a heat transfer equation to analyse the thermal conductivity in air-filled aluminium foams with complex cellular structures of different porosity. Algorithmic methods are introduced to create synthetic open-cell foam structures and to compute the thermal conductivity by means of phase-field modelling. A material law for the effective thermal conductivity is derived by determining the appropriate exponent depending on the relative density in the system. The results are compared with the thermal conductivity in massive aluminium and in pure air.
Mit der neuen Abgasnorm Euro VI und den steigenden Kraftstoffpreisen müssen Nutzfahrzeugantriebe eine Reduzierung der CO2-Emission und eine höhere Effizienz vorweisen (Umweltbundesamt, 2015). Um diese Anforderungen erfüllen zu können, wird bei vielen Nutzfahrzeugherstellern intensiv an Systemen zur Rückgewinnung von Abgasenergie, den sogenannten Waste-Heat-Recovery-Systemen, geforscht. Eine Kraftstoffersparnis von rund 5 % wird dabei angestrebt.
Das System basiert auf einem ORC-Prozess. Bei diesem thermodynamischen Kreisprozess wird die Abwärme des Abgases über einen Wärmetauscher geführt, der das organische Arbeitsfluid Ethanol in einem geschlossenen Kreislauf erhitzt. Durch den Dampfdruckaufbau wird eine Turbine angetrieben. Zur Transformation der Enthalpie des Ethanoldampfes in mechanische Energie sind Drehzahlen von bis zu 120000 U/min notwendig, um eine hohe Effizienz des Systems vorweisen zu können. Systemdrücke bis 50 bar und Temperaturen des Ethanoldampfes von maximal 300 °C treten im WHR-System auf und führen zu extremen Beanspruchungen. Eine besondere Herausforderung stellen hierbei die Wellendichtungen, vor allem bei nutzfahrzeugtypischen Lebensdauern, dar. Als interessante Alternative zeigt sich die Zentrifugal-Wellendichtung, um die hohen Dichtungsanforderungen über die geforderten Laufzeiten zuverlässig zu erfüllen.
Durch methodisch stufenweise ablauforientiertes Vorgehen wird die Analyse der Zentrifugal-Wellendichtungen durchgeführt. Hierbei wird zuallererst das Wirkprinzip untersucht. Ein besonderes Augenmerk wird dabei auf die Wärmeeinträge aus der Umgebung und Verwendung unterschiedlicher Sperrfluide gelegt.
Für eine Testdrehzahl von 15000 U/min ergibt sich, bei einer beidseitig glatten Scheibe mit einem Scheibenradius von 8,7 mm, eine maximal abdichtbare Druckdifferenz von 0,04 bar. Im Sperrfluid herrschen hierbei Temperaturen von rund 50 °C. Die Versuche zeigen Korrelationen zu den bekannten theoretischen Ansätzen von Ketola und McGrey. Die maximale Druckdifferenz beträgt in diesem Fall 0,043 bar. Nachdem stationäre Betrachtungen ausreichend untersucht werden, widmet sich diese Arbeit dem Anfahr- und Not-Aus-Verhalten. Die Optimierung des Projekts wird durch abschließende Verbesserungsvorschläge, für die Realisierung höherer Sperrdrücke, erzielt.
A two-dimensional single-phase model is developed for the steady-state and transient analysis of polymer electrolyte membrane fuel cells (PEMFC). Based on diluted and concentrated solution theories, viscous flow is introduced into a phenomenological multi-component modeling framework in the membrane. Characteristic variables related to the water uptake are discussed. A Butler–Volmer formulation of the current-overpotential relationship is developed based on an elementary mechanism of electrochemical oxygen reduction. Validated by using published V–I experiments, the model is then used to analyze the effects of operating conditions on current output and water management, especially net water transport coefficient along the channel. For a power PEMFC, the long-channel configuration is helpful for internal humidification and anode water removal, operating in counterflow mode with proper gas flow rate and humidity. In time domain, a typical transient process with closed anode is also investigated.
The state-of-the-art electrochemical impedance spectroscopy (EIS) calculations have not yet started from fully multi-dimensional modeling. For a polymer electrolyte membrane fuel cell (PEMFC) with long flow channel, the impedance plot shows a multi-arc characteristic and some impedance arcs could merge. By using a step excitation/Fourier transform algorithm, an EIS simulation is implemented for the first time based on the full 2D PEMFC model presented in the first part of this work. All the dominant transient behaviors are able to be captured. A novel methodology called ‘configuration of system dynamics’, which is suitable for any electrochemical system, is then developed to resolve the physical meaning of the impedance spectra. In addition to the high-frequency arc due to charge transfer, the Nyquist plots contain additional medium/low-frequency arcs due to mass transfer in the diffusion layers and along the channel, as well as a low-frequency arc resulting from water transport in the membrane. In some case, the impedance spectra appear partly inductive due to water transport, which demonstrates the complexity of the water management of PEMFCs and the necessity of physics-based calculations.
In the present study, in vitro toxicity as well as biopersistence and photopersistence of four artificial sweeteners (acesulfame, cyclamate, saccharine, and sucralose) and five antibiotics (levofloxacin, lincomycin, linezolid, marbofloxacin, and sarafloxacin) and of their phototransformation products (PTPs) were investigated. Furthermore, antibiotic activity was evaluated after UV irradiation and after exposure to inocula of a sewage treatment plant. The study reveals that most of the tested compounds and their PTPs were neither readily nor inherently biodegradable in the Organisation for Economic Co-operation and Development (OECD)-biodegradability tests. The study further demonstrates that PTPs are formed upon irradiation with an Hg lamp (UV light) and, to a lesser extent, upon irradiation with a Xe lamp (mimics sunlight). Comparing the nonirradiated with the corresponding irradiated solutions, a higher chronic toxicity against bacteria was found for the irradiated solutions of linezolid. Neither cytotoxicity nor genotoxicity was found in human cervical (HeLa) and liver (Hep-G2) cells for any of the investigated compounds or their PTPs. Antimicrobial activity of the tested fluoroquinolones was reduced after UV treatment, but it was not reduced after a 28-day exposure to inocula of a sewage treatment plant. This comparative study shows that PTPs can be formed as a result of UV treatment. The study further demonstrated that UV irradiation can be effective in reducing the antimicrobial activity of antibiotics, and consequently may help to reduce antimicrobial resistance in wastewaters. Nevertheless, the study also highlights that some PTPs may exhibit a higher ecotoxicity than the respective parent compounds. Consequently, UV treatment does not transform all micropollutants into harmless compounds and may not be a large-scale effluent treatment option.
The formation and analysis of ten microporous triazolyl isophthalate based MOFs, including nine isomorphous and one isostructural compound is presented. The compounds 1 M – 3 M with the general formula [ M ( R 1 - R 2 - trz - ia ) ] ∞ 3 ·x H 2 O (M 2+ = Co 2+ , Cu 2+ , Zn 2+ , Cd 2+ ; R 1 = H, Me; R 2 = 2py, 2pym, prz (2py = 2-pyridinyle; 2pym = 2-pyrimidinyle; prz = pyrazinyle)) crystallize with rtl topology. They are available as single crystals and also easily accessible in a multi-gram scale via refluxing the metal salts and the protonated ligands in a solvent. Their isomorphous structures facilitate the synthesis of heteronuclear MOFs; in case of 2 M , Co 2+ ions could be gradually substituted by Cu 2+ ions. The Co 2+ :Cu 2+ ratios were determined by ICP-OES spectroscopy, the distribution of Co 2+ and Cu 2+ in the crystalline samples are investigated by SEM-EDX analysis leading to the conclusions that Cu 2+ is more favorably incorporated into the framework compared to Co 2+ and, moreover, that the distribution of the two metal ions between the crystals and within the crystals is inhomogeneous if the crystals were grown slowly. The various compositions of the heteronuclear materials lead to different colors and the sorption properties for CO 2 and N 2 are dependent on the integrated metal ions.
Skills, abilities and capability of our freshmen are increasingly heterogeneous, regarding age, attained levels of education and motivational aspects. Additionally, students tend to recoil from subjects dealing with mathematical backgrounds. As a result high, drop-out numbers are a huge problem in technical degree programs.
Since mechanics is based on physics and mathematics our students face enormous difficulties. To deal with them, a form of teaching and learning has been developed that is composed of the following arrangements:
1. Problems and tasks of different levels are solved during lessons. The access to theoretical issues is being developed by or rather as a result of solving these problems. By doing so, especially students with yet insufficient skills are enabled to develop their methodological skills.
2. Challenging students to independently transfer these skills on other problems is helpful. At the end of each lecture two students are selected randomly. Each of them is faced with an exercise they have to solve and present at the beginning of the next lecture. Because of small student numbers, chances are high that every student participates at least once by the end of semester. Surveys show that particularly weaker students benefit from that kind of model learning.
3. We are surrounded by mechanical issues. Given that, students are presented with “every-day-life” problems which students can apply their theoretical knowledge on. The problems are analyzed by groups of students, which leads to an enhanced and reflective perception of each and every one. Some examples are: “A broomstick in equilibrium”, “Sensitive cups”, “Transforming a roman basilica into a gothic cathedral”.
4. All lectures have been filmed by the staff of the Information Center of the Offenburg University during the previous term. Additionally to the notes taken by the students individually during the lectures, these recordings are helpful in the process of preparation and post-processing of the material. The recordings are accessible via the university’s learning management system “Moodle”.
Surveys show that students benefit from the great variety of the provided, interactive learning arrangements. It is interesting to discover that students not only take positive advantages in the lecture “mechanics 1/statics” but tend to transfer these positive experiences on other subjects.
The current methods used to assess the energy performance of ventilation devices do not consider all the aspects necessary for a comprehensive evaluation of decentralised ventilation concepts and can only be partially adapted to their needs. In order to improve the energy evaluation and to ensure the comparability of different systems, a calorimetric method was developed and implemented in test facilities for the evaluation of two decentralised devices: one equipped with a recuperative counter flow heat exchanger and one with a regenerative heat exchanger. This method, based on direct measurements of the heating load in an insulated test room, includes the effect of the electrical consumption of the fans on the energy performance of the ventilation devices. The calorimetric evaluation method was extended to a seasonal evaluation on the basis of a heating-degree-day method implemented for a warm, a cool and a moderate location in Europe: Athens, Strasbourg and Copenhagen. All the results are above 50% efficiency for both devices, even in Athens where the use of heat recovery ventilation is not usual.