Ecological concerns on the climatic effects of the emissions from electricity production stipulate the remuneration of electricity grids to accept growing amounts of intermittent regenerative electricity feed-in from wind and solar power. Germany’s eager political target to double regenerative electricity production by 2030 puts pressure on grid operators to adapt and restructure their transmission and distribution grids. The ability of local distribution grids to operate autonomous of transmission grid supply is essential to stabilize electricity supply at the level of German federal states. Although congestion management and collaboration at the distribution system operator (DSO) level are promising approaches, relatively few studies address this issue. This study presents a methodology to assess the electric energy balance for the low-voltage grids in the German federal state of Baden-Württemberg, assuming the typical load curves and the interchange potential among local distribution grids by means of linear programming of the supply function and for typical seasonal electricity demands. The model can make a statement about the performance and development requirements for grid architecture for scenarios in 2035 and 2050 when regenerative energies will—according to present legislation—account for more than half of Germany’s electricity supply. The study details the amendment to Baden-Württemberg’s electricity grid required to fit the system to the requirements of regenerative electricity production. The suggested model for grid analysis can be used in further German regions and internationally to systematically remunerate electricity grids for the acceptance of larger amounts of regenerative electricity inflows. This empirical study closes the research gap of assessing the interchange potential among DSO and considers usual power loads and simultaneously usual electricity inflows.
Electric arc furnaces (EAF) are complex industrial plants whose actual behavior depends upon numerous factors. Due to its energy intensive operation, the EAF process has always been subject to optimization efforts. For these reasons, several models have been proposed in literature to analyze and predict different modes of operation. Most of these models focused on the processes inside the vessel itself. The present paper introduces a dynamic, physics-based model of a complete EAF plant which consists of the four subsystems vessel, electric system, electrode regulation, and off-gas system. Furthermore the solid phase is not treated to be homogenous but a simple spatial discretization is employed. Hence it is possible to simulate the energy input by electric arcs and fossil fuel burners depending on the state of the melting progress. The model is implemented in object-oriented, equation-based language Modelica. The simulation results are compared to literature data.
The aim of this research work was to develop a boiler model with few parameters required for energy planning. The showcase considered for this work was the boiler system of the energy center at Offenburg University of Applied Sciences. A grey box model of the boiler was developed systematically starting from model abstraction, simplification, model break-down and to the use of empirical correlations wherever necessary to describe the intermediate effects along with the use of information from manufacturer’s specification in order to reduce parameters. This strategy had resulted in a boiler model with only 6 parameters, namely, nominal burner capacity, water gallery capacity, air ratio, heat capacity of wall, thermal conductance on flue gas and hot water side. Most of these parameters can be obtained through the information available in the spec sheets and thus an energy planner will be able to parameterize the model with low effort. The model was validated with the monitored data of the showcase. It was tested for the start-up, shut-down behavior and the effect of storage.
The energy supply of Offenburg University of Applied Sciences (HS OG) was changed from separate generation to trigeneration in 2007/2008. Trigeneration was installed for supplying heat, cooling and electrical power at HS OG. In this paper, trigeneration process and its modes of operation along with the layout of the energy facility at HS OG were described. Special emphasis was given to the operation schemes and control strategies of the operation modes: winter mode, transition mode and summer mode. The components used in the energy facility were also outlined. Monitoring and data analysis of the energy system was carried out after the commissioning of trigeneration in the period from 2008 to 2011. Thus, valuable performance data was obtained.