Refine
Year of publication
- 2000 (14) (remove)
Document Type
- Conference Proceeding (4)
- Article (unreviewed) (4)
- Article (reviewed) (2)
- Contribution to a Periodical (2)
- Patent (1)
- Periodical Part (1)
Conference Type
- Konferenzartikel (2)
- Konferenzband (2)
Keywords
- Mikroelektronik (2)
- Abtastung (1)
- Arbeitsrecht (1)
- Aufhebungsvertrag (1)
- Betriebssicherheit (1)
- Bewerbung (1)
- Dünnschichtchromatographie (1)
- Faseroptik (1)
- Hydrodynamik (1)
- Particle emissions (1)
Institute
Open Access
- Open Access (7)
- Bronze (5)
- Closed (5)
- Closed Access (2)
In this paper a high-performance thin-layer chromatography (HPTLC) scanner is presented in which a special fibre arrangement is used as HPTLC plate scanning interface. Measurements are taken with a set of 50 fibres at a distance of 400 to 500 μm above the HPTLC plate. Spatial resolutions on the HPTLC plate of better than 160 μm are possible. It takes less than 2 min to scan 450 spectra simultaneously in a range of 198 to 610 nm. The basic improvement of the item is the use of highly transparent glass fibres which provide excellent transmission at 200 nm and the use of a special fibre arrangement for plate illumination and detection.
Rotating flow systems are often used to study stability phenomena and structure developments. The closed spherical gap problem is generalized into an open flow system by superimposing a mass flux in meridional direction. The basic solutions at low Reynolds numbers are described by analytical methods. The nonlinear supercritical solutions are simulated numerically and realized in experiments. Novel steady and time-dependent modes of flows are obtained. The extensive results concern the stability behaviour, non-uniqueness of supercritical solutions, symmetry behaviour and transitions between steady and time-dependent solutions. The experimental investigations concern the visualization of the various instabilities and the quatitative description of the flow structures including the laminar-turbulent transition. A comparison between theoretical and experimental results shows good agreement within the limit of rotational symmetric solutions from the theory.
A system for the on-line/in-line measurement of soot particle sizes and concentrations in the undiluted exhaust gas of diesel engines was developed and successfully tested. The unit uses the individual attenuations of three different laser wavelengths and is combined with an optical cell (white principle) with adjustable path lengths from 2.5 to 15 meters.
Risiko und Sicherheit sind Begriffe, die nur im Zusammenhang mit dem Menschen gesehen werden können, wobei bei der Risikoabschätzung die Fragen beantwortet werden müssen, was passieren kann und was passieren darf. Ausgehend von der Vornorm DIN V 19250 wird im Detail auf folgende Punkte eingegangen: Risikoparameter, Schadensausmaß, Häufigkeit, Aufenthaltsdauer im Gefahrenbereich, Gefahrenabwendung, Eintrittswahrscheinlichkeit, Bewertung der Eintrittsmöglichkeiten von Ereignissen, Restrisikoverkleinerung, Vorhersage von Schadensereignissen einschließlich Störfallauslöser. Die Demonstration erfolgt an Beispielen aus der Chemie.
Stichwort: Zwischenzeugnis
(2000)
Jeder Arbeitnehmer hat per Tarifvertrag oder bei einem triftigen Grund Anspruch auf ein Zwischenzeugnis. Typische triftige Gründe sind: Bewerbung um eine neue Stelle, wesentliche Änderungen des Aufgabengebiets, Versetzung in eine andere Abteilung oder längere Abordnung in ein Projekt, Beförderung, Wechsel oder Ausscheiden des Vorgesetzten, Nachweis einschlägiger Tätigkeiten für die Zulassung zu Prüfungen, Unterbrechung der Arbeitstätigkeit durch Erziehungsurlaub, Auslandsentsendung, feststehende Beendigung des Arbeitsverhältnisses wegen Kündigung, Aufhebungsvertrag oder Ablauf einer befristeten Tätigkeit, drohende Beendigung wegen Aufnahme von Sozialplanverhandlungen oder wegen Beginn eines Insolvenzverfahrens. Strebt ein Arbeitgeber den Abschluss eines Aufhebungsvertrags an, so sollte der Arbeitnehmer parallel zu den Verhandlungen ein Zwischenzeugnis fordern.