Refine
Document Type
- Conference Proceeding (11)
- Patent (9)
- Article (reviewed) (4)
- Contribution to a Periodical (4)
Conference Type
- Konferenz-Abstract (10)
- Konferenz-Poster (1)
Language
- English (18)
- German (8)
- Other language (1)
- Multiple languages (1)
Is part of the Bibliography
- yes (28)
Keywords
Institute
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (28) (remove)
Open Access
- Open Access (22)
- Bronze (4)
- Closed Access (3)
Disturbances of the cardiac conduction system causing reentry mechanisms above the atrioventricular (AV) node are induced by at least one accessory pathway with different conducting properties and refractory periods. This work aims to further develop the already existing and continuously expanding Offenburg heart rhythm model to visualise the most common supraventricular reentry tachycardias to provide a better understanding of the cause of the respective reentry mechanism.
The visualization of heart rhythm disturbance and atrial fibrillation therapy allow the optimization of new cardiac catheter ablations. With the simulation software CST (Computer Simulation Technology, Darmstadt) electromagnetic and thermal simulations can be carried out to analyze and optimize different heart rhythm disturbance and cardiac catheters for pulmonary vein isolation. Another form of visualization is provided by haptic, three-dimensional print models. These models can be produced using an additive manufacturing method, such as a 3D printer. The aim of the study was to produce a 3D print of the Offenburg heart rhythm model with a representation of an atrial fibrillation ablation procedure to improve the visualization of simulation of cardiac catheter ablation.
The basis of 3D printing was the Offenburg heart rhythm model and the associated simulation of cryoablation of the pulmonary vein. The thermal simulation shows the pulmonary vein isolation of the left inferior pulmonary vein with the cryoballoon catheter Arctic Front AdvanceTM from Medtronic. After running through the simulation, the thermal propagation during the procedure was shown in the form of different colors. The three-dimensional print models were constructed on the base of the described simulation in a CAD program. Four different 3D printers are available for this purpose in a rapid prototyping laboratory at the University of Applied Science Offenburg. Two different printing processes were used: 1. a binder jetting printer with polymer gypsum and 2. a multi-material printer with photopolymer. A final print model with additional representation of the esophagus and internal esophagus catheter was also prepared for printing.
With the help of the thermal simulation results and the subsequent evaluation, it was possible to make a conclusion about the propagation of the cold emanating from the catheter in the myocardium and the surrounding tissue. It could be measured that already 3 mm from the balloon surface into the myocardium the temperature drops to 25 °C. The simulation model was printed using two 3D printing methods. Both methods as well as the different printing materials offer different advantages and disadvantages. While the first model made of polymer gypsum can be produced quickly and cheaply, the second model made of photopolymer takes five times longer and was twice as expensive. On the other hand, the second model offers significantly better properties and was more durable overall. All relevant parts, especially the balloon catheter and the conduction, are realistically represented. Only the thermal propagation in the form of different colors is not shown on this model.
Three-dimensional heart rhythm models as well as virtual simulations allow a very good visualization of complex cardiac rhythm therapy and atrial fibrillation treatment methods. The printed models can be used for optimization and demonstration of cryoballoon catheter ablation in patients with atrial fibrillation.
The visualization of heart rhythm disturbance and atrial fibrillation therapy allows the optimization of new cardiac catheter ablations. With the simulation software CST (Computer Simulation Technology, Darmstadt) electromagnetic and thermal simulations can be carried out to analyze and optimize different heart rhythm disturbance and cardiac catheters for pulmonary vein isolation. Another form of visualization is provided by haptic, three-dimensional print models. These models can be produced using an additive manufacturing method, such as a 3d printer. The aim of the study was to produce a 3d print of the Offenburg heart rhythm model with a representation of an atrial fibrillation ablation procedure to improve the visualization of simulation of cardiac catheter ablation. The basis of 3d printing was the Offenburg heart rhythm model and the associated simulation of cryoablation of the pulmonary vein. The thermal simulation shows the pulmonary vein isolation of the left inferior pulmonary vein with the cryoballoon catheter Arctic Front Advance™ from Medtronic. After running through the simulation, the thermal propagation during the procedure was shown in the form of different colors. The three-dimensional print models were constructed on the base of the described simulation in a CAD program. Four different 3d printers are available for this purpose in a rapid prototyping laboratory at the University of Applied Science Offenburg. Two different printing processes were used and a final print model with additional representation of the esophagus and internal esophagus catheter was also prepared for printing. With the help of the thermal simulation results and the subsequent evaluation, it was possible to draw a conclusion about the propagation of the cold emanating from the catheter in the myocardium and the surrounding tissue. It was measured that just 3 mm from the balloon surface into the myocardium the temperature dropped to 25 °C. The simulation model was printed using two 3d printing methods. Both methods, as well as the different printing materials offer different advantages and disadvantages. All relevant parts, especially the balloon catheter and the conduction, are realistically represented. Only the thermal propagation in the form of different colors is not shown on this model. Three-dimensional heart rhythm models as well as virtual simulations allow very clear visualization of complex cardiac rhythm therapy and atrial fibrillation treatment methods. The printed models can be used for optimization and demonstration of cryoballoon catheter ablation in patients with atrial fibrillation.
Um medizinische Behandlungsverfahren in der Praxis besser verstehen und anwenden zu können, gewinnt die Visualisierung der Prozesse an immer größerer Bedeutung. Durch Anwendung der Computer-Simulationssoftware CST können elektromagnetische und thermische Simulationen zur Analyse verschiedener Herzrhythmusstörungen durchgeführt werden. Eine weitere Form der Visualisierung erfolgt durch haptische, dreidimensionale Druckmodelle. Diese Modelle können mit einem generativen Herstellungsverfahren, wie z. B. einem 3D-Drucker, in kürzester Zeit hergestellt werden.
The present invention relates to open-loop and closed-loop control units for extracorporeal circulatory support, to systems comprising such an open-loop and closed-loop control unit, and to corresponding methods. An open-loop and closed-loop control unit (10) for extracorporeal circulatory support is proposed, which is configured to receive a measurement of an ECG signal (12) of a supported patient over a predefined period of time, wherein the ECG signal (12) comprises multiple data points for each time point within a heart cycle. The open-loop and closed-loop control unit (10) comprises an evaluation unit (100) which is configured to evaluate the data points for at least one time point in a spatial and/or temporal manner and to determine at least one amplitude change (14) within the heart cycle based on the evaluated data points. The open-loop and closed-loop control unit (10) is further configured to output an open-loop and/or closed-loop signal (16) for extracorporeal circulatory support at a predefined point in time after the at least one amplitude change (14).
The present invention relates to open-loop and closed-loop control units for extracorporeal circulatory support, to systems comprising such an open-loop and closed-loop control unit, and to corresponding methods. An open-loop and closed-loop control unit (10) for extracorporeal circulatory support is proposed, which is configured to receive a measurement of an ECG signal (12) of a supported patient over a predefined period of time, wherein the ECG signal (12) comprises multiple data points for each time point within a heart cycle. The open-loop and closed-loop control unit (10) comprises an evaluation unit (100) which is configured to evaluate the data points for at least one time point in a spatial and/or temporal manner and to determine at least one amplitude change (14) within the heart cycle based on the evaluated data points. The open-loop and closed-loop control unit (10) is further configured to output an open-loop and/or closed-loop signal (16) for extracorporeal circulatory support at a predefined point in time after the at least one amplitude change (14).
Device and method for monitoring and optimising a temporal trigger stability (WO2023094554A1)
(2023)
The present invention relates to devices for monitoring and optimising a temporal trigger stability of an extracorporeal circulatory support means, and to open-loop and closed-loop control units for the extracorporeal circulatory support means comprising such a device, and to corresponding methods. A device (10) for monitoring a temporal trigger stability of an extracorporeal circulatory support means is accordingly proposed, which device is designed to receive a first dataset (14) of a measurement of an ECG signal of a supported patient over a predefined period of time. The device (10) comprises an evaluation unit (16), which is designed to determine or identify a plurality of R triggers (26) from the first dataset (14), wherein the evaluation unit (16) is also designed to receive or provide a second dataset (20) having evaluated ECG signals and a plurality of R triggers (28) and to selectively map the second dataset (20) on the first dataset (14). The device is also designed to emit a signal (22) that characterises a temporal gap between successive R triggers (26) from the first dataset (14) and successive R triggers (28) from the second dataset (20) which are mapped on the first dataset.
Background: A disturbed synchronization of the ventricular contraction can cause a highly developed systolic heart failure in affected patients, which can often be explained by a diseased left bundle branch block (LBBB). If medication remains unresponsive, the concerned patients will be treated with a cardiac resynchronization therapy (CRT) system. The aim of this study was to integrate His bundle pacing into the Offenburg heart rhythm model in order to visualize the electrical pacing field generated by His bundle pacing.
Methods: Modelling and electrical field simulation activities were performed with the software CST (Computer Simulation Technology) from Dessault Systèms. CRT with biventricular pacing is to be achieved by an apical right ventricular electrode and an additional left ventricular electrode, which is floated into the coronary vein sinus. This conventional type of biventricular pacing leads to a reduction of the left ventricular ejection fraction. Furthermore, the non-responder rate of the CRT therapy is about one third of the CRT patients.
Results: His bundle pacing represents a physiological alternative to conventional cardiac pacing and cardiac resynchronization. An electrode implanted in the His bundle emits a stronger electrical pacing field than the electrical pacing field of conventional cardiac pacemakers. The pacing of the His bundle was performed by the Medtronic Select Secure 3830 electrode with pacing voltage amplitudes of 3 V, 2 V and 1.5 V in combination with a pacing pulse duration of 1 ms.
Conclusions: Compared to conventional cardiac pacemaker pacing, His bundle pacing is capable of bridging LBBB conduction disorders in the left ventricle. The His bundle pacing electrical field is able to spread via the physiological pathway in the right and left ventricles for CRT with a narrow QRS-complex in the surface ECG.
A disturbed synchronization of the ventricular contraction can cause a highly developed systolic heart failure in affected patients with reduction of the left ventricular ejection fraction, which can often be explained by a diseased left bundle branch block (LBBB). If medication remains unresponsive, the concerned patients will be treated with a cardiac resynchronization therapy (CRT) system. The aim of this study was to integrate His-bundle pacing into the Offenburg heart rhythm model in order to visualize the electrical pacing field generated by His-Bundle-Pacing. Modelling and electrical field simulation activities were performed with the software CST (Computer Simulation Technology) from Dessault Systèms. CRT with biventricular pacing is to be achieved by an apical right ventricular electrode and an additional left ventricular electrode, which is floated into the coronary vein sinus. The non-responder rate of the CRT therapy is about one third of the CRT patients. His- Bundle-Pacing represents a physiological alternative to conventional cardiac pacing and cardiac resynchronization. An electrode implanted in the His-bundle emits a stronger electrical pacing field than the electrical pacing field of conventional cardiac pacemakers. The pacing of the Hisbundle was performed by the Medtronic Select Secure 3830 electrode with pacing voltage amplitudes of 3 V, 2 V and 1,5 V in combination with a pacing pulse duration of 1 ms. Compared to conventional pacemaker pacing, His-bundle pacing is capable of bridging LBBB conduction disorders in the left ventricle. The His-bundle pacing electrical field is able to spread via the physiological pathway in the right and left ventricles for CRT with a narrow QRS-complex in the surface ECG.