Refine
Year of publication
- 2012 (68) (remove)
Document Type
- Conference Proceeding (28)
- Article (reviewed) (17)
- Article (unreviewed) (8)
- Contribution to a Periodical (7)
- Part of a Book (5)
- Book (2)
- Patent (1)
Conference Type
- Konferenzartikel (20)
- Konferenz-Abstract (7)
- Sonstiges (1)
Language
- English (68) (remove)
Is part of the Bibliography
- yes (68)
Keywords
- Adsorption (5)
- Metallorganisches Netzwerk (4)
- Dünnschichtchromatographie (2)
- Kohlendioxid (2)
- RoboCup (2)
- Signaltechnik (2)
- 2D-TLC (1)
- Aircraft (1)
- Ammoniumverbindungen (1)
- Attenuation (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (31)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (17)
- Fakultät Wirtschaft (W) (11)
- Zentrale Einrichtungen (6)
- CRT - Campus Research & Transfer (2)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (2)
- WLRI - Work-Life Robotics Institute (2)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Open Access (31)
- Closed Access (17)
- Closed (9)
- Bronze (5)
The Humboldt digital library (HDL) represents an innovative system to access the works and legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question about how to present interconnected data in an appropriate form using information technologies. The HDL has been created as a dynamic digital library with the capability of connecting multilingual and multimedia data from diverse online archives. Humboldt’s volumes have become available, but beyond that any relevant information related to the observations of Humboldt, even outside the works can become immediately accessible. This makes it possible to recognize natural changes and compare Humboldt’s descriptions with recent situations. The technology we have developed addresses the issues of sustainability and makes it possible to detect changes in the environment since the time of Humboldt’s observations.
The newly synthesized Zn4O-based MOF 3∞[Zn4(μ4-O){(Metrz-pba)2mPh}3]·8 DMF (1·8 DMF) of rare tungsten carbide (acs) topology exhibits a porosity of 43% and remarkably high thermal stability up to 430 °C. Single crystal X-ray structure analyses could be performed using as-synthesized as well as desolvated crystals. Besides the solvothermal synthesis of single crystals a scalable synthesis of microcrystalline material of the MOF is reported. Combined TG-MS and solid state NMR measurements reveal the presence of mobile DMF molecules in the pore system of the framework. Adsorption measurements confirm that the pore structure is fully accessible for nitrogen molecules at 77 K. The adsorptive pore volume of 0.41 cm3 g−1 correlates well with the pore volume of 0.43 cm3 g−1 estimated from the single crystal structure.
The invention relates to a container (1) for a liquid medium (3), in particular a blood bag, comprising a flexible outer wall (5) and a device (13) connected to the container (1) for acquiring and/or storing data. According to the invention, the device (13) for acquiring and/or storing data is arranged within the flexible outer wall (5), wherein positioning means (15) are provided which hold the device (13) for acquiring and/or storing data in a floating manner in the liquid medium when the container (1) is filled with said liquid medium (3), and wherein the device (13) or the device (13) and the positioning means (15) are designed such that the mass of liquid medium (3) which is displaced in each case is essentially equal to the mass of the device (13) or to the mass of the device (13) and the positioning means (15).
We will present the first example of a two-dimensional scanned TLC-plate, measured by use of a diode-array scanner. A spatial resolution of 250 µm was achieved on plate. The system provides real 2D fluorescence and absorption spectra in the wavelength-range from 190 to 1000 nm with a spectral resolution of greater than 1 nm. A mixture of 12 sulphonamides was separated by using a cyanopropyl-coated silica gel plate (Merck, 1.16464) with the solvent mix of methyl tert-butyl ether-methanol-dichloromethane-cyclohexane-NH3 (25%) (48:2:2:1:1, v/v) in the first and with a mixture of water-acetonitrile-dioxane-ethanol (8:2:1:1, v/v) in the second direction. Both developments were carried out over a distance of 70 mm. A separation number (spot capacity) of 259 was calculated. We discussed a new formula for its calculation in 2D-TLC separations. The drawback of this method is that measuring a 2D-TLC plate needs more than 3 h measurement time.
The following paper presents the results of a feasibility study about Bluetooth Low Energy (BLE) based wireless sensors. The development of industrial wireless sensors leads to important demands for the wireless technologies like a low energy consumption and a resource saving simple protocol stack. Bluetooth Low Energy (BLE) is a rather new wireless standard which will completely fulfill these fundamental requirements. A self-designed BLE sensor system has been used to explore the common applicability of BLE for wireless sensor systems. The evaluation results of various analyses with the BLE sensor system are now presented in this paper.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
Experiences with a telecare platform integration of ZigBee sensors into a middleware platform
(2012)
In cardiac resynchronization therapy (CRT) for heart failure, individualization of the AV delay is essential to improve hemodynamics and to minimize non-responder rate. In patients in sinus rhythm having additional disposition to bradycardia, optimization is necessary for both situations, atrial sensing and pacing. Therefore, echo-optimization is the goldstandard but time consuming. Unfortunately, it depends on the particular CRT systems parameter set if the resulting individually optimal AV delays can be programmed or not. Some CRT systems provide a set of AV delays for DDD operation combined with a set of the pace-sense-compensation to optimize the AV delay in DDD and VDD operation. The pace-sense-compensation (PSC) can be defined by the difference of implant-related interatrial conduction intervals in DDD and VDD operation measured in the esophageal left atrial electrogram. In a cohort of 96 CRT patients we found mean PSC of 59-35ms ranging between 0-143ms. As a consequence, allowing 10ms tolerance, AVD optimization is completely impossible in one of the two modes, VDD or DDD operation, in 34 (35%) or 5 (5%) patients with implants restricting the PSC range to 60ms or 100ms, respectively. Thus, we propose companies to provide CRT systems with programmable pace-sense- compensation between 0ms and 150ms.