Refine
Year of publication
- 2014 (32) (remove)
Document Type
- Article (reviewed) (32) (remove)
Has Fulltext
- no (32)
Keywords
- Intelligentes Stromnetz (4)
- Elektrolyt (3)
- Lithiumbatterie (3)
- Management (2)
- Netzwerk (2)
- Analyse (1)
- Anomalie (1)
- Arzneimittel (1)
- Aufbereitung (1)
- BACnet (1)
Institute
Open Access
- Closed Access (16)
- Open Access (3)
Impedance of the Surface Double Layer of LSCF/CGO Composite Cathodes: An Elementary Kinetic Model
(2014)
A wide range catalyst screening with noble metal and oxide catalysts for a metal–air battery with an aqueous alkaline electrolyte was carried out. Suitable catalysts reduce overpotentials during the charge and discharge process, and therefore improve the round-trip efficiency of the battery. In this case, the electrodes will be used as optimized cathodes for a future lithium–air battery with an aqueous alkaline electrolyte. Oxide catalysts were synthesized via atmospheric plasma spraying. The screening showed that IrO2, RuO2, La0.6Ca0.4Co3, Mn3O4, and Co3O4 are promising bi-functional catalysts. Considering the high price for the noble metal catalysts further investigations of the oxide catalysts were carried out to analyze their electrochemical behavior at varied temperatures, molarities, and in case of La1−x Ca x CoO3 a varying calcium content. Additionally all catalysts were tested in a longterm test to proof cyclability at varied molarities. Further investigations showed that Co3O4 seems to be the most promising bi-functional catalyst of the tested oxide catalysts. Furthermore, it was shown that a calcium content of x = 0.4 in LCCO has the best performance.
Ansatzpunkte zur Verknüpfung von Wertmanagement und Wertemanagement aus Sicht der Führungspraxis
(2014)
Energy management in distribution grids is one of the key challenges that needs to be overcome to increase the share of fluctuating renewable energies. Current control systems for energy management mainly demonstrate centralized- or decentralized-hierarchical control structures. Very few systems manifest a fully decentralized multiagent-based control structure. Multiagent-based control systems promise to be an advantageous approach for the future distributed energy supply system because no central control entity is necessary, which eases parameterization in case of grid topology changes, and the agents are more stable against failures and changes of control topologies. Research is necessary to prove these benefits. In this study, we introduce a design of a multiagent-based voltage control system for low-voltage grids. In detail we introduce cooperative decision-making processes and software solutions that allow the agents to perceive and control their environment, the agent-discovery and localization in different types of communication networks, agent-to-agent communication, and the integration of the multiagent system in existing grid-control infrastructures. Furthermore, the study proposes how different existing technologies can be combined into an applicable multiagent-based voltage control system: the Java/OSGi-based OpenMUC framework allows a generic field–device interaction; peer-to-peer discovery and session establishment functionalities are combined with the agent communication defined by the Foundation for Intelligent Physical Agents (FIPA). The ripple control-signal technology is applied as a fallback communication between the agent and a central grid-control center.
Turbinen aus der Tragetasche
(2014)
Am Karlsruher Institut für Technologie wurde der Prototyp eines Kleinwindkraftwerks zur autarken Stromversorgung entwickelt. Das "Energypack" genannte System besteht aus einem 1,10 m langen PVC-Gehäuse mit dreieckigem Querschnitt, Generator, Seilen sowie Funkgerät und kostet ab 50 Euro. Mit dem Energypack kann ein Dynamo mit 2,5 W angetrieben werden. An der Dualen Hochschule BW Heidenheim wurde das System "Anemotec" entworfen, das anstelle von Windflügeln über ein schraubenähnliches Gewinde verfügt. Der Rotor und die Windführung bestehen aus glasfaserverstärkten Werkstoffen. Die erzeugte Leistung liegt bei 365 W, die Stromgestehungskosten liegen bei 23 Cent pro kWh. Die von der Hochschule Offenburg entwickelte Windturbine "Windzip" arbeitet mit einem H-Rotor und besteht aus neun leicht gekrümmten Blechen, die wie Planeten in unterschiedlichem Abstand und in unterschiedlicher Höhe um einen vertikalen Stab kreisen. Bei einer Windgeschwindigkeit von 10 Meter pro Sekunde wurde damit eine Leistung von 40 W erzeugt.
A laser-operated, angle-tunable transducer was employed to excite selectively elastic waves guided along the apex of a solid wedge. The propagation of wedge waves at anisotropic monocrystalline silicon edges with different symmetry properties was studied by optical detection. The reduced symmetry in crystals, as compared to isotropic media, causes a number of new features, such as the existence of supersonic leaky wedge waves, tilted spatial pulse profiles, and other peculiarities of their localization. Experimental and theoretical results are presented for three different types of symmetry configurations: the wedge symmetric about its midplane, the wedge symmetric about the plane normal to its apex line, and the wedge symmetric about one of its faces. The experiments include accurate measurements of the phase velocity and the wave field distribution, providing information on localization and coupling of wedge waves with other waves. Theoretically, the wedge waves were treated by the Laguerre function method, extended to modes that are not localized at the tip of the wedge. This approach allowed an accurate description of the observed localized and leaky wedge waves in anisotropic wedges.