Refine
Year of publication
Document Type
- Conference Proceeding (303)
- Article (reviewed) (112)
- Article (unreviewed) (32)
- Part of a Book (13)
- Letter to Editor (11)
- Patent (9)
- Contribution to a Periodical (8)
- Book (5)
- Bachelor Thesis (4)
- Master's Thesis (2)
Conference Type
- Konferenzartikel (212)
- Konferenz-Abstract (61)
- Sonstiges (21)
- Konferenz-Poster (8)
- Konferenzband (1)
Language
- English (501) (remove)
Keywords
- RoboCup (20)
- Kommunikation (13)
- Eingebettetes System (8)
- Intelligentes Stromnetz (8)
- Brennstoffzelle (7)
- Batterie (6)
- Lithiumbatterie (6)
- Abtragung (5)
- Applikation (5)
- CST (5)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (501) (remove)
Open Access
- Closed Access (196)
- Open Access (175)
- Closed (58)
- Bronze (48)
- Gold (2)
- Diamond (1)
The IEEE 1588 precision time protocol (PTP) is a time synchronization protocol with sub-microsecond precision primarily designed for wired networks. In this letter, we propose wireless precision time protocol (WPTP) as an extension to PTP for multi-hop wireless networks. WPTP significantly reduces the convergence time and the number of packets required for synchronization without compromising on the synchronization accuracy.
In this paper we integrate the ideas of network coding and relays into an existing practical network architecture used in a wireless network scenario. Specifically, we use the COPE architecture to test our ideas. Since previous works have focused on the communication aspect at the physical layer level, we attempt to take it one step further by including the MAC layer. Our idea is based on information theoretic concepts developed by Shannon in order to reliably apply network coding to increase the net throughput.
Home Care Applications and Ambient Assisted Living become increasingly attractive. This is caused as well by market pull, as the number of elderly people grows monotonously, as well as by technology push, as technological advances and attractive products pave the way to economically advantageous offerings. However, in real-life applications, a significant number of challenges remain. Those include seamless communication between products from different supplier, due to the lack of sufficiently standardized solutions, energy budgets, and scalability of solutions. This paper presents the experience from the InCASA project (Integrated Network for Completely Assisted Senior Citizen's Autonomy), where architectures for heterogeneous physical and logical communication flows are examined.
In the past two decades much has been published on whiplash injury, yet both the confusion regarding the condition, and the medicolegal discussion about it have increased. In this paper, functional imaging research results are summarized using MRIcroGL3D visualization software and assembled in an image comprising regions of cerebral activation and deactivation.
A novel approach of a test environment for embedded networking nodes has been conceptualized and implemented. Its basis is the use of virtual nodes in a PC environment, where each node executes the original embedded code. Different nodes run in parallel, connected via so-called virtual channels. The environment allows to modifying the behavior of the virtual channels as well as the overall topology during runtime to virtualize real-life networking scenarios. The presented approach is very efficient and allows a simple description of test cases without the need of a network simulator. Furthermore, it speeds up the process of developing new features as well as it supports the identification of bugs in wireless communication stacks. In combination with powerful test execution systems, it is possible to create a continuous development and integration flow.
Nowadays the processing power of mobile phones, Smart phones and PDA is increasing, as well as the transmission bandwidth. Nevertheless there is still the need to reduce the content and the need of processing the data. Proposals and solutions for dynamic reduction of the transmitted content will be discussed. For that, device specific properties will be taken into account, aiming at reducing the need of processing power at the client side to display the 3D Virtual Reality data. Therefore, well known technologies like data compression are combined with new approaches to achieve the goal of adaptive content transmission. For device dependant reduction of processing power the data has to be pre-processed at the server side or the server itself has to take over functionality of weak mobile devices.
Cardiac resynchronization therapy is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and prolongation of QRS duration. The aim of the study was to evaluate ventricular desynchronization with electrical interventricular delay (IVD) to left ventricular delay (LVD) ratio in atrial fibrillation heart failure patients. IVD and LVD were measured by transesophageal posterior left ventricular ECG recording. In atrial fibrillation heart failure patients with prolonged QRS duration, the mean IVD-to-LVD-ratio was 0.84 +/- 0.42 with a range from 0.17 to 2.2 IVD-to-LVD-ratio. IVD-to-LVD-ratio correlated with QRS duration. IVD-to-LVD-ratio may be a useful parameter to evaluate electrical ventricular desynchronization in atrial fibrillation heart failure patients.
The application of leaky feeder (radiating) cables is a common solution for the implementation of reliable radio communication in huge industrial buildings, tunnels and mining environment. This paper explores the possibilities of leaky feeders for 1D and 2D localization in wireless systems based on time of flight chirp spread spectrum technologies. The main focus of this paper is to present and analyse the results of time of flight and received signal strength measurements with leaky feeders in indoor and outdoor conditions. The authors carried out experiments to compare ranging accuracy and radio coverage area for a point-like monopole antenna and for a leaky feeder acting as a distributed antenna. In all experiments RealTrac equipment based on nanoLOC radio standard was used. The estimation of the most probable path of a chirp signal going through a leaky feeder was calculated using the ray tracing approach. The typical non-line-of-sight errors profiles are presented. The results show the possibility to use radiating cables in real time location technologies based on time-of-flight method.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation, but not all patients improved clinically. Aim of this study was to evaluate electrical intra-left ventricular conduction delay (LVCD) and interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 65 HF patients (age 63.4 ± 10.6 years; 7 females, 58 males) with New York Heart Association (NYHA) class 3 ± 0.2, 24.4 ± 6.7 % left ventricular (LV) ejection fraction and 167.4 ± 35.6 ms QRSD were included. Esophageal TO Osypka focused hemispherical electrodes catheter was perorally applied in position of maximum LV deflection to measure LVCD between onset and offset of LV deflection and IVCD between earliest onset of QRS in the 12-channel surface ECG and onset of LV deflection in the focused bipolar transesophageal LV electrogram.
Results: There were 50 responders with LVCD of 76.5 ± 20.4 ms, IVCD of 80.5 ± 26.1 ms (P=0.34) and QRSD of 171 ± 37.7 ms. 15 non-responders had longer LVCD of 90 ± 28.5 ms (P = 0.045), shorter IVCD of 50.1 ± 29.1 ms (P < 0.001) and QRSD of 155.3 ± 25 ms (P=0.14). During 21.3 ± 20.3 month BV pacing follow-up, the responder`s NYHA classes improved from 3 ± 0.2 to 2. ± 0.3 (P < 0.001) whereas the non-responders NYHA classes did not improve from 3 ± 0.2 to 2.9 ± 0.3 (P = 0.43) during 15.7 ± 13.9 month BV pacing follow-up (53 Boston, 10 Medtronic and 2 St. Jude CRT devices).
Conclusion: Determination of electrical LVCD and IVCD by focused bipolar transesophageal LV electrogram recording may be an additional useful technique to improve patient selection for CRT.
In this work, we consider a duty-cycled wireless sensor network with the assumption that the on/off schedules are uncoordinated. In such networks, as all nodes may not be awake during the transmission of time synchronization messages, nodes will require to re-transmit the synchronization messages. Ideally a node should re-transmit for the maximum sleep duration to ensure that all nodes are synchronized. However, such a proposition will immensely increase the energy consumption of the nodes. Such a situation demands that there is an upper bound of the number of retransmissions. We refer to the time a node spends in re-transmission of the control message as broadcast duration. We ask the question, what should be the broadcast duration to ensure that a certain percentage of the available nodes are synchronized. The problem to estimate the broadcast duration is formulated so as to capture the probability threshold of the nodes being synchronized. Results show the proposed analytical model can predict the broadcast duration with a given lower error margin under real world conditions, thus demonstrating the efficiency of our solution.
In this paper we propose a motion framework forbipedal robots that decouples motion definitions from stabilizingthe robot. This simplifies motion definitions yet allows dynamicmotion adaptations. Two applications, walking and stopping onone leg, demonstrate the power of the framework. We show thatour framework is able to perform walking and stopping on one legeven under extreme conditions and improves walking benchmarkssignificantly in the RoboCup 3D soccer simulation domain.
Transthoracic impedance cardiography (ICG) is a non-invasive method for determination of hemodynamic parameters. The basic principle of transthoracic ICG is the measurement of electrical conductivity of the thorax over the time. The aim of the study was the analysis of hemodynamic parameters from healthy individuals and the evaluation of various hemodynamic monitoring devices. Fourteen men (mean age 25 ± 4.59 years) and twelve women (mean age 24 ± 3.5 years) were measured during the cardiovascular engineering laboratory at Offenburg University of Applied Sciences, Offenburg, Germany. The ICG recordings were measured with the devices CardioScreen 1000, CardioScreen 2000 and TensoScreen with the corresponding Software Cardiovascular Lab 2.5 (Medis Medizinische Messtechnik GmbH, Illmenau, Germany). In order to create identical frame conditions, all measurements were recorded in the same position and for the same duration. Various positions were simulated from horizontal lying position to vertical standing position. Altogether, more than 30 hemodynamic parameters were measured.
Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients with sinus rhythm and ventricular desynchronisation. The aim of this study was to evaluate interventricular conduction delay (IVCD) and interatrial conduction delay (IACD) before and after premature ventricular contractions (PVC) in HF patients.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association functional class 2,8 ± 0.5, left ventricular (LV) ejection fraction 28,6 ± 12,6 %, 154 ± 25 ms QRS duration and PVC were analysed with bipolar transesophageal LV and left atrial electrogram recording and National Instruments LabView 2009 software. The level of significance of the t-test is 0,005.
Results: QRS duration increases during PVC (188 ± 32 ms) in comparison to the beat before (154 ± 25 ms, P = ) and after PVC (152 ± 25 ms,). IVCD increases during PVC up to 65 ± 33 ms (51 ± 19 ms in the beat before PVC, P=0.18, 49 ± 19 ms after PVC, P = 0.12). Intra-LV delay of 90 ± 16 ms is not different in the beat before PVC, 90 ± 14 ms during PVC (P = 0.99) and 94 ± 16 ms in the beat after PVC (P = 0.38). IACD is not significantly PVC influenced (67 ± 12 ms before PVC and 65 ± 13 ms after PVC, P = 0.71). Intra-left atrial conduction delay is not significant longer during PVC (57 ± 28 ms) than in the beat before PVC (54 ± 13 ms, P = 0.51) or after PVC (54 ± 8 ms, P = 0.45). PQ duration increases significantly after PVC (224 ± 95 ms) in comparison to the beat before PVC (176± 29 ms, P =...).
Conclusion: Transesophageal left cardiac electrocardiography with LabView 2009 software can improve evaluation of IVCD and IACD before, during and after PVC in HF patient selection for CRT.
BACKGROUND:
While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL.
METHODS:
This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada.
RESULTS:
A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable.
CONCLUSION:
A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
The CAN bus still is an important fieldbus in various domains, e.g. for in-car communication or automation applications. To counter security threats and concerns in such scenarios we design, implement, and evaluate the use of an end-to-end security concept based on the Transport Layer Security protocol. It is used to establish authenticated, integrity-checked, and confidential communication channels between field devices connected via CAN. Our performance measurements show that it is possible to use TLS at least for non time-critical applications, as well as for generic embedded networks.
Wireless communication systems more and more become part of our daily live. Especially with the Internet of Things (IoT) the overall connectivity increases rapidly since everyday objects become part of the global network. For this purpose several new wireless protocols have arisen, whereas 6LoWPAN (IPv6 over Low power Wireless Personal Area Networks) can be seen as one of the most important protocols within this sector. Originally designed on top of the IEEE802.15.4 standard it is a subject to various adaptions that will allow to use 6LoWPAN over different technologies; e.g. DECT Ultra Low Energy (ULE). Although this high connectivity offers a lot of new possibilities, there are several requirements and pitfalls coming along with such new systems. With an increasing number of connected devices the interoperability between different providers is one of the biggest challenges, which makes it necessary to verify the functionality and stability of the devices and the network. Therefore testing becomes one of the key components that decides on success or failure of such a system. Although there are several protocol implementations commonly available; e.g., for IoT based systems, there is still a lack of according tools and environments as well as for functional and conformance testing. This article describes the architecture and functioning of the proposed test framework based on Testing and Test Control Notation Version 3 (TTCN-3) for 6LoWPAN over ULE networks.
The embedding of microwave devices is treated by applying the finite-difference method to three-dimensional shielded structures. A program package was developed to evaluate electromagnetic fields inside arbitrary transmission-line connecting structures and to compute the scattering matrix. The air bridge, the transition through a wall, and the bond wire are examined as interconnecting structures. Detailed results are given and discussed regarding the fundamental behavior of embedding.
Temperature regulation is an important component for modern high performance single -core and multi-core processors. Especially high operating frequencies and architectures with an increasing number of monolithically integrated transistors result in a high power dissipation and - since processor chips convert the consumed electrical energy into thermal energy - in high operating temperatures. High operating temperatures of processors can have drastic consequences regarding chip reliability, processor performance, and leakage currents. External components like fans or heat spreaders can help to reduce the processor temperature - with the disadvantage of additional costs and reduced reliability. Therefore, software based algorithms for dynamic temperature management are an attractive alternative and well known as Dynamic Thermal Management (DTM). However, the existing approaches for DTM are not taking into account the requirements of real-time embedded computing, which is the objective in the given project. The first steps are the profiling and the thermal modeling of the system, which is reported in this paper for a Freescale i. MX6Q quad-core microprocessor. An analytical model is developed and verified by an extensive set of measurement runs.
This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2018 adult size humanoid competition. Sweaty came 2nd in RoboCup 2017 adult size league. The main characteristics of Sweaty are described in the Team Description Paper 2017. The improvements that have been made or are planned to be implemented for RoboCup 2018 are described in this paper.
This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2017 adult size humanoid competition. Sweaty came 2nd in RoboCup 2016 adult size league. The paper describes the main characteristics of Sweaty that made this success possible, and improvements that have been made or are planned to be implemented for RoboCup 2017.
This paper describes the new Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2016 adult size humanoid competition. Based on experiences during RoboCup 2014, the Sweaty robot has been completely redesigned to a new robot Sweaty II. A major change is the use of linear actuators for the legs. Another characteristic is its indirect actuation by means of rods. This allows a variable transmission ratio depending on the angle of a joint.
This paper describes the new Sweaty humanoid adult size robot trying to qualify for the RoboCup 2014 adult size humanoid competition. The robot is built from scratch to eventually allow it to run. One characteristic is that to prevent the motors from overheating, water evaporation is used for cooling. The robot is literally sweating which has given it its name. Another characteristic is, that the motors are not directly connected to the frame but by means of beams. This allows a variable transmission ratio depending on the angle.
The suffix-free-prefix-free hash function construction and its indifferentiability security analysis
(2012)
In this paper, we observe that in the seminal work on indifferentiability analysis of iterated hash functions by Coron et al. and in subsequent works, the initial value (IV) of hash functions is fixed. In addition, these indifferentiability results do not depend on the Merkle–Damgård (MD) strengthening in the padding functionality of the hash functions. We propose a generic n-bit-iterated hash function framework based on an n-bit compression function called suffix-free-prefix-free (SFPF) that works for arbitrary IVs and does not possess MD strengthening. We formally prove that SFPF is indifferentiable from a random oracle (RO) when the compression function is viewed as a fixed input-length random oracle (FIL-RO). We show that some hash function constructions proposed in the literature fit in the SFPF framework while others that do not fit in this framework are not indifferentiable from a RO. We also show that the SFPF hash function framework with the provision of MD strengthening generalizes any n-bit-iterated hash function based on an n-bit compression function and with an n-bit chaining value that is proven indifferentiable from a RO.
Routine nuclear cardiology examinations indicate heart rate, cardiac rhythm, the height of cardiac pulse and respiration rhythm. It would be of interest to study whether these data, especially if the same tests are repeated, can indicate patients’ well being in the future and perhaps patients’ life span, other factors being equal. Related old theories and suggestions are mentioned. Furthermore, some drugs like I-f channel antagonists and stress tests testing cardiac reserves could support such a study.
The overview of public key infrastructure based security approaches for vehicular communications
(2015)
Modern transport infrastructure becomes a full member of globally connected network. Leading vehicle manufacturers have already triggered development process, output of which will open a new horizon of possibilities for consumers and developers by providing a new communication entity - a car, thus enabling Car2X communications. Nevertheless some of available systems already provide certain possibilities for vehicles to communicate, most of them are considered not sufficiently secured. During last 15 years a number of big research projects funded by European Union and USA governments were started and concluded after which a set of standards were published prescribing a common architecture for Car2X and vehicles onboard communications. This work concentrates on combining inner and outer vehicular communications together with a use of Public Key Infrastructure (PKI).
Chronic insomnia is defined by difficulties in falling asleep, maintaining sleep, and early morning awakening, and is coupled with daytime consequences such as fatigue, attention deficits, and mood instability. These symptoms persist over a period of at least 3 months (Diagnostic and Statistical Manual 5 criteria). Chronic insomnia can be a symptom of many medical, neurological, and mental disorders. As a disorder, it incurs substantial health-care and occupational costs, and poses substantial risks for the development of cardiovascular and mental disorders, including cognitive deficits. Family and twin studies confirm that chronic insomnia can have a genetic component (heritability coefficients between 42% and 57%), whereas the investigation of autonomous and central nervous system parameters has identified hyperarousal as a final common pathway of the pathophysiology, implicating an imbalance of sleep–wake regulation consisting of either overactivity of the arousal systems, hypoactivity of the sleep-inducing systems, or both. Insomnia treatments include benzodiazepines, benzodiazepine-receptor agonists, and cognitive behavioural therapy. Treatments currently under investigation include transcranial magnetic or electrical brain stimulation, and novel methods to deliver psychological interventions.
In this TDP we describe a new tool created for testing the strategy layer of our soccer playing agents. It is a complete 2D simulator that simulates the games based on the decisions of 22 agents. With this tool, debugging the decision and strategy layer of our agents is much more efficient than before due to various interaction methods and complete control over the simulation.
In the future, the tool could also serve as a measure to run simulations of game series much faster than with the 3D simulator. This way, the impact of different play strategies could be evaluated much faster than before.
After having described many different aspects of our team software in previous years, in this paper we take the freedom to describe the magmaChallenge framework provided by the magmaOffenburg team. The framework is used as a benchmark tool to run different challenges like the running challenge in 2014 or the kick accuracy challenge in 2015. This description should serve as a documentation to simplify the maintenance by the community and to add new benchmarks in the future.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2013. While last year’s TDP focused on different ways how robot behavior can be defined in the magmaOffenburg framework this year we focus on how we statistically evaluate new features on distributed systems. We also show some results gained through such analysis.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2011. While last year’s TDP focused on the tool set created for 3D simulation in this year we describe the further improvement in this tools as well as some new features we implemented focusing on heterogeneous robot models which seem to be used in RoboCup 2012.
An additional tool was written to simply generate situation-dependent strategies. Furthermore some tools, described last year, are now integrated in one single GUI to easy things up.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2010. While last year’s TDP focused on decisions making using extended behavior networks and on its software architecture and implementation in this year we describe the tool set that was created for RoboCup 3D. It contians a GUI for agent- and world state visualization, for evaluation of localization algorithms and benchmarks in general, a visual editor for Extended Behavior Networks creation and debugging, a live movement tool to interact with the joints and finally a tool for editing behavior motor files.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2009. It focuses on two distinctive features of the team: decisions making using extended behavior networks and its software architecture and implementation in Java to open the simulation for the Java community.
The Internet of Things (IoT), ubiquitous computing and ubiquitous connectivity, Cyber Physical Systems (CPS), ambient intelligence, Machine-to-Machine communication (M2M) or Car-to-Car (C2C)-communication, smart metering, smart grid, telematics, telecare, telehealth – there are many buzzwords around current developments related to the Internet.
This contribution gives an overview on such IoT-applications, as they are already used today to improve the availability of information, increase efficiency, push system limits and extend the value chain. At a closer look, the economic and technical development can be separated into different phases. It is interesting that we are currently at the threshold to a new phase, with decentralized and cooperative communication and control nodes as cornerstones. Thus, embedded systems and their connectivity are in the middle of the scene.
This recent development is described along with some example projects from the author’s team which are used in industrial automation, energy supply and distribution (home automation and smart metering), traffic engineering (cooperative driver assistance systems), and in telehealth and telecare.
Ranging errors are inevitable in all local positioning systems, including those based on Time-of-Flight (ToF) technique. Results of experiments show that the major cause for these errors is a signal degradation from multipath propagation. This effect is especially critical in case of Non-Light-of-Sight (NLOS) conditions. This paper describes causes that affects ranging errors for nanoLOC™-TOF-technology and presents estimations for the probability density functions of such errors under different NLOS conditions. The provided estimations allow the improvement of the accuracy of the localization through the subsequent mitigation of the ranging errors from the measurements. Additionally, it is proposed to increase the number of cases of NLOS-conditions for the improvement of the accuracy.
The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users
(2016)
Objective: The present study evaluated whether the poorer baseline performance of cochlear implant (CI) users or the technical and/or physiological properties of CI stimulation are responsible for the absence of masking release. Design: This study measured speech reception thresholds (SRTs) in continuous and modulated noise as a function of signal to noise ratio (SNR). Study sample: A total of 24 subjects participated: 12 normal-hearing (NH) listeners and 12 subjects provided with recent MED-EL CI systems. Results: The mean SRT of CI users in continuous noise was −3.0 ± 1.5 dB SNR (mean ± SEM), while the normal-hearing group reached −5.9 ± 0.8 dB SNR. In modulated noise, the difference across groups increased considerably. For CI users, the mean SRT worsened to −1.4 ± 2.3 dB SNR, while it improved for normal-hearing listeners to −18.9 ± 3.8 dB SNR. Conclusions: The detrimental effect of fluctuating maskers on SRTs in CI users shown by prior studies was confirmed by the current study. Concluding, the absence of masking release is mainly caused by the technical and/or physiological properties of CI stimulation, not just the poorer baseline performance of many CI users compared to normal-hearing subjects. Speech understanding in modulated noise was more robust in CI users who had a relatively large electrical dynamic range.
The aim of this data collection is to enforce evidence of SCS effectiveness in treating neuropathic chronic pain and the very low percentage of undesired side effects of complications reported in our case series suggests that all implants should be performed by similarly well-trained and experienced professionals.
Security in IT systems, particularly in embedded devices like Cyber Physical Systems (CPSs), has become an important matter of concern as it is the prerequisite for ensuring privacy and safety. Among a multitude of existing security measures, the Transport Layer Security (TLS) protocol family offers mature and standardized means for establishing secure communication channels over insecure transport media. In the context of classical IT infrastructure, its security with regard to protocol and implementation attacks has been subject to extensive research. As TLS protocols find their way into embedded environments, we consider the security and robustness of implementations of these protocols specifically in the light of the peculiarities of embedded systems. We present an approach for systematically checking the security and robustness of such implementations using fuzzing techniques and differential testing. In spite of its origin in testing TLS implementations we expect our approach to likewise be applicable to implementations of other cryptographic protocols with moderate efforts.
An investigation is underway regarding the usefulness of altazimuth-mounting telescopes' incorporation of laser gyros for pointing and fiber gyros with extremely small random-walk coefficient for telescope inertial stabilization during tracking. A star tracker is expected to help stabilize long-term gyro bias. Gyro and telescope specifications have been derived by means of computer simulations and systems analyses.
Both German and French Air-Source Heat Pump (ASHP) markets have been enjoying an overall upwards trend for many years but, nevertheless, they remain merely slightly penetrated. In terms of market players and their share, the French market is aptly diversified, whereas the German one, being utterly dominated by one single manufacturer, is badly in need of some diversification. At the same time Korean ASHP manufacturers are targeting the French but not German ASHP market. The main purpose of the paper is to find out likely reasons for their one-sided engagement, primarily those associated with the ASHP technology and its system-related aspects.
This paper presents the elements and the results from the European research project inCASA (Integrated Network for Completely Assisted Senior Citizen’s Autonomy), which designed and implemented a seamless integration of heterogeneous systems and network protocols for regionally distributed telecare and telehealth applications. The integration includes a multitude of physical interface, the transcoding of data models using embedded middleware, and a backend system with open interfaces. The implementation was verified in field tests in five European countries.
Network landscape of recent time contains many different network technologies, a wide range of end-devices with a large scale of capabilities and power, and an immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices, will increase their diversity and variety. In this paper software architecture has been proposed to establish device and content format independent communication including 3D imaging and virtual reality data as content. As experimental validation the concept is implemented in collaborative Language Learning Game (LLG), which is a learning tool for language acquisition.
A laser-operated, angle-tunable transducer was employed to excite selectively elastic waves guided along the apex of a solid wedge. The propagation of wedge waves at anisotropic monocrystalline silicon edges with different symmetry properties was studied by optical detection. The reduced symmetry in crystals, as compared to isotropic media, causes a number of new features, such as the existence of supersonic leaky wedge waves, tilted spatial pulse profiles, and other peculiarities of their localization. Experimental and theoretical results are presented for three different types of symmetry configurations: the wedge symmetric about its midplane, the wedge symmetric about the plane normal to its apex line, and the wedge symmetric about one of its faces. The experiments include accurate measurements of the phase velocity and the wave field distribution, providing information on localization and coupling of wedge waves with other waves. Theoretically, the wedge waves were treated by the Laguerre function method, extended to modes that are not localized at the tip of the wedge. This approach allowed an accurate description of the observed localized and leaky wedge waves in anisotropic wedges.
Structured Innovation with TRIZ in Science and Industry - Creating Value for Customers and Society
(2016)
Since their dawning, space communications have been among the strongest driving applications for the development of error correcting codes. Indeed, space-to-Earth telemetry (TM) links have extensively exploited advanced coding schemes, from convolutional codes to Reed-Solomon codes (also in concatenated form) and, more recently, from turbo codes to low-density parity-check (LDPC) codes. The efficiency of these schemes has been extensively proved in several papers and reports. The situation is a bit different for Earth-to-space telecommand (TC) links. Space TCs must reliably convey control information as well as software patches from Earth control centers to scientific payload instruments and engineering equipment onboard (O/B) spacecraft. The success of a mission may be compromised because of an error corrupting a TC message: a detected error causing no execution or, even worse, an undetected error causing a wrong execution. This imposes strict constraints on the maximum acceptable detected and undetected error rates.
The combination of fossil-derived fuels with ethanol and methanol has acquired relevance and attention in several countries in recent years. This trend is strongly affected by market prices, constant geopolitical events, new sustainability policies, new laws and regulations, etc. Besides bio-fuels these materials also include different additives as anti-shock agents and as octane enhancer. Some of the chemical compounds in these additives may have harmful properties for both environment and public health (besides the inherent properties, like volatility). We present detailed Raman spectral information from toluene (C7H8) and ethanol (C2H6O) contained in samples of ElO gasoline-ethanol blends. The spectral information has been extracted by using a robust, high resolution Fourier-Transform Raman spectrometer (FT-Raman) prototype. This spectral information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm-1 to 3500 cm-1 with a resolution of 1.66cm-1. This allows resolving tight adjacent Raman lines like the ones observed around 1003cm-1 and 1030cm-1 (characteristic lines of toluene). The Raman spectra obtained show a reduced frequency deviation when compared to standard Raman spectra from different calibration materials. The FT-Raman spectrometer prototype used for the analysis consist basically of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling is achieved with conventional62.5/125μm multi-mode fibers. This FT-Raman setup is able to extract high resolution and frequency precise Raman spectra from the additives in the fuels analyzed. The proposed prototype has no additional complex hardware components or costly software modules. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by accurately extracting the optical path information of the Michelson interferometer. This is accomplished by generating an additional interference pattern with a λ = 632.8 nm Helium-Neon laser (HeNe laser). It enables the FT-Raman system to perform reliable and clean spectral measurements from the materials under observation.
Targeting complex fractionated atrial electrocardiograms by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies and catheter ablation of atrial fibrillation and ventricular tachycardia. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardigraphy allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm use automatic ECG trigger function for signal averaged transthoracic, transesophageal and intra-cardiac ECG signals with novel LabVIEW software.
Results: The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. We evaluated atrial flutter in the time domain with two-to-one atrioventricular conduction, 212.0 ± 4.1 ms atrial cycle length, 426.0 ± 8.2 ms ventricular cycle length, 58.2 ± 1.8 ms P-wave duration, 119.6 ± 6.4 ms PQ duration, 103.0 ± 2.4 ms QRS duration and 296.4 ± 6.8 ms QT duration. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can be utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial and ventricular electrocardiograms may be useful parameters to evaluate electrical cardiac bradycardia and tachycardia signals in atrial fibrillation and ventricular tachycardia ablation.
Spectral analysis of signal averaging electrocardiography in atrial and ventricular tachyarrhythmias
(2017)
Background: Targeting complex fractionated atrial electrograms detected by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardiography (ECG) allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm uses automatic ECG trigger function for signal averaged transthoracic, transesophageal and intracardiac ECG signals with novel LabVIEW software (National Instruments, Austin, Texas, USA). For spectral analysis we used fast fourier transformation in combination with spectro-temporal mapping and wavelet transformation for evaluation of detailed information about the frequency and intensity of high frequency atrial and ventricular signals.
Results: Spectral-temporal mapping and wavelet transformation of the signal averaged ECG allowed the evaluation of high frequency fractionated atrial signals in patients with atrial fibrillation and high frequency ventricular signals in patients with ventricular tachycardia. The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex. The combination of analysis in the time and frequency domain allowed the evaluation of fractionated signals during atrial and ventricular conduction.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial electrograms may be useful parameters to evaluate electrical cardiac arrhythmogenic signals in atrial fibrillation ablation.
The industry of the agave-derived bacanora, in the northern Mexican state of Sonora, has been growing substantially in recent years. However, this higher demand still lies under the influences of a variety of social, legal, cultural, ecological and economic elements. The governmental institutions of the state have tried to encourage a sustainable development and certain levels of standardization in the production of bacanora by applying different economical and legal strategies. However, a large portion of this alcoholic beverage is still produced in a traditional and rudimentary fashion. Beyond the quality of the beverage, the lack of proper control, by using adequate instrumental methods, might represent a health risk, as in several cases traditional-distilled beverages can contain elevated levels of harmful materials. The present article describes the qualitative spectral analysis of samples of the traditional-produced distilled beverage bacanora in the range from 0 cm−1 to 3500 cm−1 by using a Fourier Transform Raman spectrometer. This particular technique has not been previously explored for the analysis of bacanora, as in the case of other beverages, including tequila. The proposed instrumental arrangement for the spectral analysis has been built by combining conventional hardware parts (Michelson interferometer, photo-diodes, visible laser, etc.) and a set of self-developed evaluation algorithms. The resulting spectral information has been compared to those of pure samples of ethanol and to the spectra from different samples of the alcoholic beverage tequila. The proposed instrumental arrangement can be used the analysis of bacanora.
The formation of secondary phases in the porous electrodes is a severe mechanism affecting the lifetime of solid oxide fuel cells (SOFC). It can occur via various chemical mechanisms and it has a significant influence on cell performance due to pore clogging and deactivation of active surfaces and triple-phase boundary (TPB). We present a modeling and simulation study of nickel oxide formation (reoxidation) and carbon formation (coking) within the SOFC anode. We use a 2D continuum model based on a multi-phase framework [Neidhardt et al., J. Electrochem. Soc., 159, 9 (2012)] that allows the introduction of arbitrary solid phases (here: Ni, YSZ, NiO, Carbon) plus gas phase. Reactions between the bulk phases are modeled via interface-adsorbed species and are described by an elementary kinetic approach. Published experimental data are used for parameterization and validation. Simulations allow the prediction of cell performance under critical operation conditions, like (i) a non-fuel operation test, where NiO formation is taking place (Figure 1a), or (ii) an open circuit voltage (OCV) stability test under hydrocarbon atmosphere, where solid carbon is formed (Figure 1b). Results are applied for enhanced interpretation of experimental data and for prediction of safe operation conditions.
Under a grant of the German ProInno program („Erhöhung der Innovationskompetenz mittelständischer Unternehmen“)the Hochschule Offenburg participated during the past 2 years in an industry project prototyping a new type of service for modern Air Traffic Control (ATC) applications.<br> Objective of the project has been the joint development of hardware and software components for a so-called TIS-B (Traffic Information System - Broadcast) support infrastructure to enable new cockpit applications increasing the air situation awareness for pilots of commercial airliners [1]. At the core of the project is a space-time-scheduler, controlling a battery of TIS-B groundstations over a Wide Area Surveillance Network [4].<br> The project has been successfully concluded and is currently in its evaluation phase. Industry partner was the Karlsruhe-located company COMSOFT, international market leader in ATC sensor networks.
ECG simulators, available on the market, imitate the electric activity of the heart in a simplified manner. Thus, they are suitable for education purposes but not really for testing algorithms to recognize complex arrhythmias needed for pacemakers and implantable defibrillators. Especially certain discrimination between various morphologies of atrial and ventricular fibrillation needs simulators providing native electrograms of different patients’ heart rhythm events. This explains the necessity to develop an ECG simulator providing high-resolution native intracardiac and surface electrograms of in-vivo rhythm events. In this paper we demonstrate an approach for an ECG simulator based on a consumer multichannel soundcard and a corresponding software application for a laptop computer. This Live-ECG Simulator is able to handle invasive electrogram recordings from electrophysiological studies and send the data to a modified external soundcard for subsequent digital to analog conversion. The hardware is completed with an electronic circuit providing level adjustment to adapt the output amplitude to the input conditions of several cardiac implants.
The improvements in the hardware and software of communication devices have allowed running Virtual Reality (VR) and Augmented Reality (AR) applications on those. Nowadays, it is possible to overlay synthetic information on real images, or even to play 3D on-line games on smart phones or some other mobile devices. Hence the use of 3D data for business and specially for education purposes is ubiquitous. Due to always available at hand and always ready to use properties of mobile phones, those are considered as most potential communication devices. The total numbers of mobile phone users are increasing all over the world every day and that makes mobile phones the most suitable device to reach a huge number of end clients either for education or for business purposes. There are different standards, protocols and specifications to establish the communication among different communication devices but there is no initiative taken so far to make it sure that the send data through this communication process will be understood and used by the destination device. Since all the devices are not able to deal with all kind of 3D data formats and it is also not realistic to have different version of the same data to make it compatible with the destination device, it is necessary to have a prevalent solution. The proposed architecture in this paper describes a device and purpose independent 3D data visibility any time anywhere to the right person in suitable format. There is no solution without limitation. The architecture is implemented in a prototype to make an experimental validation of the architecture which also shows the difference between theory and practice.
Smoothie: a solution for device and content independent applications including 3D imaging as content
(2014)
Network landscape of recent time contains many different network technologies, a wide range of end-devices with a large scale of capabilities and power, and an immense quantity of information represented in different data formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices and will increase their diversity and variety. A lot of effort is being made in order to establish open, scalable and seamless integration of various technologies and content presentation for different devices including those that are mobile, considering the individual situation of the end user. Till today the research is going on in different parts of the world but the task is not completed yet. The goal of this research work is to find a way to solve the above stated problems by investigating system architectures to provide unconstrained, continuous and personalized access to the content and interactive applications everywhere and at anytime with different devices. As a Solution of the problem considered, a new architecture named “Smoothie” is proposed.
Smartphones Welcome! Preparatory Course in Mathematics using the Mobile App MassMatics. Case Study
(2015)
Private households constitute a considerable share of Europe's electricity consumption. The current electricity distribution system treats them as effectively passive individual units. In the future, however, users of the electricity grid will be involved more actively in the grid operation and can become part of intelligent networked collaborations. They can then contribute the demand and supply flexibility that they dispose of and, as a result, help to better integrate renewable energy in-feed into the distribution grids.
Innovative technologies and concepts will emerge as we move towards a more dynamic, service-based, market-driven infrastructure, where energy efficiency and savings can be facilitated by interactive distribution networks. A new generation of fully interactive Information and Communication Technologies (ICT) infrastructure has to be developed to support the optimal exploitation of the changing, complex business processes and to enable the efficient functioning of the deregulated energy market for the benefit of citizens and businesses. The architecture of such distributed system landscapes must be designed and validated, standards need to be created and widely supported, and comprehensive, reliable IT applications will need to be implemented. The collaboration between a smart house and a smart grid is a promising approach which, with the help of ICT can fully unleash the capabilities of the smart electricity network.
The electrical field (E-field) of the biventricular (BV) stimulation is important for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex.
The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
The modeling and simulation was carried out using the electromagnetic simulation software CST. Five multipolar left ventricular (LV) electrodes, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modelled. A selection were integrated into the heart rhythm model (Schalk, Offenburg) for the electrical field simulation. The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
The BV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode with a pulse width of 0.5 ms each. The far-field potential at the RA electrode tip was 32.86 mV and 185.97 mV at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal ablation electrode. The temperature at the catheter tip was 103.87 °C after 5 s ablation time and 37.61 °C at a distance of 2 mm inside the myocardium. After 15 s, the temperature was 118.42 °C and 42.13 °C.
Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF and could be used to optimize the CRT and AF ablation.
Background: The electrical field (E-field) of the biventricular (BV) stimulation is important for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex. The 3D modeling allows the simulation of CRT and high frequency (HF) ablation.
Purpose: The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of atrial and BV stimulation and high frequency (HF) ablation in atrial fibrillation (AF).
Methods: The modeling and simulation was carried out using the electromagnetic simulation software CST (CST Darmstadt). Five multipolar left ventricular (LV) electrodes, one epicardial LV electrode, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modeled. Selected electrodes were integrated into the Offenburg heart rhythm model for the electrical field simulation. The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
Results: The right atrial stimulation was performed with an amplitude of 1.5 V with a pulse width of 0.5. The far-field potentials generated by the atrial stimulation were perceived by the right and left ventricular electrode. The far-field potential at a distance of 1 mm from the right ventricular electrode tip was 36.1 mV. The far-field potential at a distance of 1 mm from the left ventricular electrode tip was measured with 37.1 mV. The RV and LV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode with a pulse width of 0.5 ms each. The far-field potentials generated by the BV stimulations could be perceived by the RA electrode. The far-field potential at the RA electrode tip was 32.86 mV. AV node ablation was simulated with an applied power of 5 W at 420 kHz and 10 W at 500 kHz at the distal 8 mm ablation electrode.
Conclusions: Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF. The 3D simulation of the electrical field and temperature profile may be used to optimize the CRT and AF ablation.
Background: The electrical field (E-field) of the biventricular (BV) stimulation is essential for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex. 3D modeling allows the simulation of CRT and high frequency (HF) ablation.
Purpose: The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
Methods: The modeling and simulation was carried out using the electromagnetic simulation software. Five multipolar left ventricular (LV) electrodes, one epicardial LV electrode, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modeled. Different models of electrodes were integrated into a heart rhythm model for the electrical field simulation (fig.1). The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
Results: The RV and LV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode, each with a pulse width of 0.5 ms. The far-field potentials generated by the BV stimulations were perceived by the RA electrode. The far-field potential at the RA electrode tip was 32.86 mV. A far-field potential of 185.97 mV resulted at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the catheter tip was 103.87 ° C after 5 s ablation time, 44.17 ° C from the catheter tip in the myocardium and 37.61 ° C at a distance of 2 mm. After 10 s, the temperature at the three measuring points described above was 107.33 ° C, 50.87 ° C, 40.05 ° C and after 15 seconds 118.42 ° C, 55.75 ° C and 42.13 ° C.
Conclusions: Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF. The 3D simulation of the electrical field and temperature profile may be used to optimize the CRT and AF ablation.
WirelessHART protocol was specifically designed for real-time communication in the wireless sensor networks domain for industrial process automation requirements. Whereas the major purpose of WirelessHART is the read-out of sensors with moderate real-time requirements, an increasing demand for integration of actuator applications can be observed. Therefore, it must be verified that the WirelessHART protocol gives sufficient support to real-time industry requirements. As a result, the delay of especially burst and command messages from actuator and sensor nodes to the gateway and vice versa must be analyzed. In this paper, we implemented a WirelessHART network scenario in WirelessHART simulator in NS-2 [8], simulated and analyzed its time characteristics under ideal and noisy conditions. We evaluated the performance of the implementation in order to verify whether the requirements of industrial process and control can be met. This implementation offers an early alternative to expensive test beds for WirelessHART in real-time actuator applications.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.
Cardiac resynchronization therapy with biventricular pacing is an established therapy for heart failure patients with electrical left ventricular desynchronization. The aim of this study was to evaluate left atrial conduction delay, intra left atrial conduction delay, left ventricular conduction delay and intra left ventricular conduction delay in heart failure patients using novel signal averaging transesophageal left heart ECG software.
Methods: 8 heart failure patients with dilated cardiomyopathy (DCM), age 68 ± 9 years, New York Heart Association (NYHA) class 2.9 ± 0.2, 24.8 ± 6.7 % left ventricular ejection fraction, 188.8 ± 15.5 ms QRS duration and 8 heart failure patients with ischaemic cardiomyopathy (ICM), age 67 ± 8 years, NYHA class 2.9 ± 0.3, 32.5 ± 7.4 % left ventricular ejection fraction and 167.6 ± 19.4 ms QRS duration were analysed with transesophageal and transthoracic ECG by Bard LabDuo EP system and novel National Intruments LabView signal averaging ECG software.
Results: The electrical left atrial conduction delay was 71.3 ± 17.6 ms in ICM versus 72.3 ± 12.4 ms in DCM, intra left atrial conduction delay 66.8 ± 8.6 ms in ICM versus 63.4 ± 10.9 ms in DCM and left cardiac AV delay 180.5 ± 32.6 ms in ICM versus 152.4 ± 30.4 ms in DCM. The electrical left ventricular conduction delay was 40.9 ± 7.5 ms in ICM versus 42.6 ± 17 ms in DCM and intra left ventricular conduction delay 105.6 ± 19.3 ms in ICM versus 128.3 ± 24.1 ms in DCM.
Conclusions: Left heart signal averaging ECG can be utilized to analyse left atrial conduction delay, intra left atrial conduction delay, left ventricular conduction delay and intra left ventricular conduction delay to improve patient selection for cardiac resynchronization therapy.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Introduction: Cardiac resynchronization therapy (CRT) with left ventricular (LV) pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation and reduced LV ejection fraction (EF). The aim of this study was to test the utilization of the transesophageal approach to measure arterial pulse pressure (PP) during LV pacing and electrical interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 32 HF patients (age 64 ± 10 years; 5 females, 27 males) with New York Heart Association (NYHA) class 2.8 ± 0.6, 27 ± 11 % LV EF and 155 ± 35 ms QRS duration were analysed with semi-invasive left cardiac pacing and electrocardiography. Esophageal TO8 Osypka catheter of 10.5 F diameter was perorally applied to the esophagus and placed in the position of maximum left atrial (LA) deflection and maximum LV deflection to measure PP with VAT or D00 pacing modes.
Results: Temporary transesophageal LV pacing was possible with VAT mode (n=16) and D00 mode (n=16) in all patients. In 15 Δ-PP-responders, PP was higher during LV pacing on than LV pacing off (78.3 ± 26.6 versus 65.9 ± 23.7 mmHg, P < 0.001) and NYHA class improved from 3.1 ± 0.35 to 2.1 ± 0.35 (P < 0.001) during 29 ± 26 month biventricular (BV) pacing follow-up (6 Medtronic and 9 Boston BV pacing devices). In 17 Δ-PP-non-responders, PP was not higher during LV pacing on than LV pacing off (61.5 ± 23.9 versus 60.9 ± 23.5 mmHg, P = 0.066). IVCD was significant longer in Δ-PP-responders than in Δ-PP-non-responders (87 ± 33 ms versus 37± 29 ms, P < 0.001).
Conclusion: Semi-invasive transesophageale LA and LV pacing with D00 and VAT mode and LV electrogram recording may be useful techniques to predict CRT improvement.
Semi-invasive electromechanical target interval to guide left ventricular electrode placement
(2011)
Using guideline parameters for indication of cardiac resynchronization therapy (CRT), only about two thirds of the patients improve clinically. Unfortunately both, surface ECG and echo are uncertain to predict CRT response. To better characterize cardiac desynchronization in heart failure, interventricular (IVCD) and intra-leftventricular conduction delays (ILVCD) were measured by esophageal left ventricular electrogram (LVE). Recordings in 43 CRT patients (34m, 9f, age: 64.7 ± 9.5yrs) evidenced only weak correlation between IVCD and QRS of 0.53 and between ILVCD and QRS of 0.33. This demonstrated that QRS duration is not a reliable indicator of desynchronization. Therefore, the study resulted into development of LVE feature for a programmer with implant support device. It can be used interoperatively to guide the left ventricular electrode location in order to increase responder rate in CRT.
We present a novel scheme for Slotted ALOHA random access systems that combines physical-layer network coding (PLNC) with multiuser detection (MUD). The PLNC and MUD are applied jointly at the physical layer to be able to extract any linear combination of messages experiencing a collision within a slot. The set of combinations extracted from a whole frame is then processed by the receiver to recover the original packets. A simple precoding stage at the transmitting terminals allows the receiver to further decrease the packet loss rate. We present results for the decoding at the physical layer as well as several performance measures at frame level, namely, throughput, packet loss rate, and energy efficiency. The results we present are promising and suggest that a cross-layer approach leveraging on the joint use of PLNC and MUD can significantly improve the performance of random access systems in the presence of slow fading.
A wide range catalyst screening with noble metal and oxide catalysts for a metal–air battery with an aqueous alkaline electrolyte was carried out. Suitable catalysts reduce overpotentials during the charge and discharge process, and therefore improve the round-trip efficiency of the battery. In this case, the electrodes will be used as optimized cathodes for a future lithium–air battery with an aqueous alkaline electrolyte. Oxide catalysts were synthesized via atmospheric plasma spraying. The screening showed that IrO2, RuO2, La0.6Ca0.4Co3, Mn3O4, and Co3O4 are promising bi-functional catalysts. Considering the high price for the noble metal catalysts further investigations of the oxide catalysts were carried out to analyze their electrochemical behavior at varied temperatures, molarities, and in case of La1−x Ca x CoO3 a varying calcium content. Additionally all catalysts were tested in a longterm test to proof cyclability at varied molarities. Further investigations showed that Co3O4 seems to be the most promising bi-functional catalyst of the tested oxide catalysts. Furthermore, it was shown that a calcium content of x = 0.4 in LCCO has the best performance.
Background: R-wave synchronised atrial pacing is an effective temporary pacing
therapy in infants with postoperative junctional ectopic tachycardia. In the technique
currently used, adverse short or long intervals between atrial pacing and ventricular
sensing (AP–VS) may be observed during routine clinical practice.
Objectives: The aim of the study was to analyse outcomes of R-wave synchronised
atrial pacing and the relationship between maximum tracking rates and AP–VS
intervals.
Methods: Calculated AP–VS intervals were compared with those predicted by experienced
pediatric cardiologist.
Results: A maximum tracking rate (MTR) set 10 bpm higher than the heart rate (HR)
may result in undesirable short AP–VS intervals (minimum 83 ms). A MTR set 20 bpm
above the HR is the hemodynamically better choice (minimum 96 ms). Effects of either
setting on the AP–VS interval could not be predicted by experienced observers. In our
newly proposed technique the AP–VS interval approaches 95 ms for HR > 210 bpm
and 130 ms for HR < 130 bpm. The progression is linear and decreases strictly
(− 0.4 ms/bpm) between the two extreme levels.
Conclusions: Adjusting the AP–VS interval in the currently used technique is complex
and may imply unfavorable pacemaker settings. A new pacemaker design is advisable
to allow direct control of the AP–VS interval.