Refine
Year of publication
Document Type
- Conference Proceeding (303)
- Article (reviewed) (112)
- Article (unreviewed) (32)
- Part of a Book (13)
- Letter to Editor (11)
- Patent (9)
- Contribution to a Periodical (8)
- Book (5)
- Bachelor Thesis (4)
- Master's Thesis (2)
Conference Type
- Konferenzartikel (212)
- Konferenz-Abstract (61)
- Sonstiges (21)
- Konferenz-Poster (8)
- Konferenzband (1)
Language
- English (501) (remove)
Keywords
- RoboCup (20)
- Kommunikation (13)
- Eingebettetes System (8)
- Intelligentes Stromnetz (8)
- Brennstoffzelle (7)
- Batterie (6)
- Lithiumbatterie (6)
- Abtragung (5)
- Applikation (5)
- CST (5)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (501) (remove)
Open Access
- Closed Access (196)
- Open Access (175)
- Closed (58)
- Bronze (48)
- Gold (2)
- Diamond (1)
The embedding of microwave devices is treated by applying the finite-difference method to three-dimensional shielded structures. A program package was developed to evaluate electromagnetic fields inside arbitrary transmission-line connecting structures and to compute the scattering matrix. The air bridge, the transition through a wall, and the bond wire are examined as interconnecting structures. Detailed results are given and discussed regarding the fundamental behavior of embedding.
Structures for interconnecting active microwave semiconductor-devices, e.g. FET's and MIC's, with the electrical surrounding or with each other have to be designed more and more carefully when increasing the desired upper frequency limit. Therefore, several connecting structures for device embedding have been examined. Mainly, their applicability for the frequency range from 10 GHz to 100 GHz was considered. Additionally, different equivalent circuits were developed to approximately describe their behaviour for CAD-applications.
It is demonstrated that microwave structures incorporating dielectric resonators (DR) are accurately characterised by means of a 3-dimensional finite-difference CAD package. All major assumptions made so far have been dropped, offering the possibility of a rigorous analysis of the embedding of dielectric resonators into microwave structures. In particular, a finite thickness for the microstrip conductor has been taken into account. The coupling of the DR to a microstrip placed in a metallic housing has been theoretically and experimentally investigated. Theoretical and experimental results are in good agreement and give new insight into DR coupling to microstrip circuits.
The advantages of the coupling-of-modes (COM) formalism and the transmission-matrix approach are combined to create exact and computationally efficient analysis and synthesis CAD tools for the design of SAW-resonator filters. The models for the filter components, especially gratings, interdigital transducers (IDTs). and multistrip couplers (MSCs), are based on the COM approach, which delivers closed-form expressions. In order to determine the relevant COM parameters, the integrated COM differential equations are compared with analytically derived expressions from the transmission-matrix approach. The most important second-order effects such as energy storage, propagation loss and mechanical and electrical loading are fully taken into account. As an example, the authors investigate a two-pole, acoustically coupled resonator filter at 914.5 MHz on AT quartz. Excellent agreement between theory and measurement is found.
The advantages of the coupled-mode (COM) formalism and the transmission-matrix approach are combined in order to create exact and computationally efficient analysis and synthesis tools for the design of coupled surface acoustic wave resonator filters. The models for the filter components, in particular gratings, interdigital transducers (IDTs) and multistrip couplers (MSCs), are based on the COM approach that delivers closed-form expressions. To determine the pertinent COM parameters, the COM differential equations are solved and the solution is compared with analytically derived expressions from the transmission-matrix approach and the Green's function method. The most important second-order effects, such as energy storage, propagation loss, and mechanical and electrical loading, are fully taken into account. As an example, a two-pole, acoustically coupled resonator filter at 914.5 MHz on AT quartz is investigated. Excellent agreement between theory and measurement is found.
An investigation is underway regarding the usefulness of altazimuth-mounting telescopes' incorporation of laser gyros for pointing and fiber gyros with extremely small random-walk coefficient for telescope inertial stabilization during tracking. A star tracker is expected to help stabilize long-term gyro bias. Gyro and telescope specifications have been derived by means of computer simulations and systems analyses.
A polarization mode dispersion measurement set-up based on a Mach-Zehnder Interferometer was realized. Measurements were carried out on short high-birefringent fibers and on long standard telecommunication single-mode fibers. In order to ensure high accurate results, special emphasis was placed on the evaluation of the interference pattern. The procedure will be described in detail and practical measurement results will be presented.
The prototype of an optical gyro encoder (OGE) has been successfully tested on the NTT telescope in September '93. The OGE consists of a ring laser gyro and a fiber optic gyro with their input axis parallel. The gyro outptu signals are compensated for earth rotation and misalignment and are subsequently integrated to get the angles. An adaptive digital control loop locks the fiber optic gyro to the laser gyro data. Thus the combined output has the precision of the laser gyro and the low noise of the fiber optic gyro. Specifically, the bias stability is better than 2 X 10-3 deg/h, the scale factor accuracy better than 1 ppm, the random walk coefficient better than 5 X 10-4 deg/(root)h and the resolution better than 3 X 10-4 arcsec. The OGE has been mounted in the altitude and in the azimuthy axis of the telescope. The data were compared with the telescope disk encoder data. The test data show that the pointing accuracy is about 1 arcsec and the tracking accuracy 0.1 arcsec over a time of 30 seconds. This accuracy is sufficient for the very large telescope, for instance.
This paper treats the Brillouin backscattering in a single mode optical fiber and its implications on the Brillouin Ring Laser Gyroscope (BRLG). The BRLG consists of a fiber ring cavity in which stimulated Brillouin scattering is induced and provides two resonant counterpropagating backscattered waves. If this cavity is rotating around its axis, the backscattered waves get different resonant frequencies because of the Sagnac effect. The frequency difference is proportional to the rotation rate (Omega) by inducing a frequency offset between the counterpropagating waves. Some reported Brillouin spectra exhibit several peaks, which means that one pump wave provides at least two backscattered waves with distinguishable frequencies. In order to understand this multi-backscattering and to take advantage of it for the BRLG, we present results of a simulation of the Brillouin backscattering in a single mode optical fiber.
This paper treats the interaction between acoustic modes and light (Brillouin scattering) in a single mode optical fibre. Different observed spectra of the Brillouin backscattering in several fibres have been already reported. In order to have a clear idea of the process, we made a simulation to be able to `draw' the theoretical Brillouin spectrum of an optical fibre and to identify the origin of the observed backscattered lines.
First, the model and the computation method used in our simulation are described. Second, the experimentally observed spectra of two real fibres are compared with their computed spectra. Real spectra and simulated spectra are in good agreement.
Our work provides an interesting tool to investigate the changes in the Brillouin spectrum when the input parameters (characteristics of an optical fibre) vary. This should give useful indications to people working on systems which use Brillouin backscattering.
Formal verification (FV) is considered by many to be complicated and to require considerable mathematical knowledge for successful application. We have developed a methodology in which we have added formal verification to the verification process without requiring any knowledge of formal verification languages. We use only finite-state machine notation, which is familiar and intuitive to designers. Another problem associated with formal verification is state-space explosion. If that occurs, no result is returned; our method switches to random simulation after one hour without results, and no effort is lost. We have compared FV against random simulation with respect to development time, and our results indicate that FV is at least as fast as random simulation. FV is superior in terms of verification quality, however, because it is exhaustive.
The flow field-flow fractionation (FIFFF) technique is a promising method for separating and analysing particles and large size macromolecules from a few nanometers to approximately 50 μm. A new fractionation channel is described featuring well defined flow conditions even for low channel heights with convenient assembling and operations features. The application of the new flow field-flow fractionation channel is proved by the analysis of pigments and other small particles of technical interest in the submicrometer range. The experimental results including multimodal size distributions are presented and discussed.
The importance of obtaining simultaneous particle size and concentration values has grown up with continuing discussion of the health effects, of internal combustion engine generated particulate emissions and in particular of Diesel soot emissions. In the present work an aerosol measurement system is described that delivers information about particle size and concentration directly from the undiluted exhaust gas.
Using three laser diodes of different wavelengths which form one parallel light beam, each spectral attenuation is analysed by a single detector and the particle diameter and concentration is evaluated by the use of the Mie theory and shown on-line at a frequency of 1 Hz. The system includes an optical long-path-cell (White principle) with an adjustable path length from 2.5 to 15 m, which allows the analysis within a broad concentration range.
On-line measurements of the particulate emissions in the hot, undiluted exhaust of Diesel engines are presented under stationary and transient engine’s load conditions. Mean particle diameters well below 100 nm are detected for modern Diesel engines. The measured particle concentration corresponds excellently with the traditional gravimetrical measurements of the diluted exhaust. Additionally, measurements of particle emissions (mostly condensed hydricarbons) from a two-stroke engine are presented and discussed.
The bandwidth behavior of graded-index multimode fibers (GI-MMFs) for different launching conditions is investigated to understand and characterize the effect of differential mode delay. In order to reduce the launch-power distribution the near field of a single-mode fiber is used to produce a controlled restricted launch. The baseband response is measured by observing the broadening of a narrow input pulse (time-domain measurement). The paper verifies the degradation in bandwidth due to profile distortion by scanning the spot of the single-mode fiber with a transversal offset from the center of the test sample. In addition, the impact of the launch-power distribution tuned by different spot-size diameters is demonstrated. Measurements were taken on ‘older’ 50-μm and 62.5-μm GI-MMFs as well as on laser-performance-optimized fibers more recently developed.
Bluetooth personal area networks (PANs) share the 2.4 GHz ISM spectrum with the IEEE 802.11b wireless local area networks (WLANs). With the popularity of wireless devices, this ISM spectrum is becoming more and more crowded. As a result of this interference between WLANs and PANs, the performance of each network is decreased. Current research has not significantly covered the degrading impact of an 802.11b interferer on Bluetooth voice transmission. Within this project, simulations were carried out to precisely study the impact of an 802.11b interferer on the performance of Bluetooth voice transmission at different ratio levels of Bluetooth power to WLAN power at the receiver side. Furthermore, the impact of SNR on the Bluetooth voice performance and the benefit of using the SCORT packet type was analysed as well. Based on the results presented, network performance can be evaluated at the desired activity level.
Nowadays the processing power of mobile phones, smartphones and PDAs is increasing as well as the transmission bandwidth. Nevertheless there is still the need to reduce the content and the need of processing the data. We discuss the proposals and solutions for dynamic reduction of the transmitted content. For that, device specific properties are taken into account, as much as for the aim to reduce the need of processing power at the client side to be able to display the 3D (virtual reality) data. Therefore, well known technologies, e.g. data compression are combined with new developed ideas to reach the goal of adaptive content transmission. To achieve a device dependant reduction of processing power the data have to be preprocessed at the server side or the server even has to take over functionality of weak mobile devices.
Experimental and theoretical investigations of the time of equalization of the concentration of an impurity in a rectangular flow‐type chamber have been carried out. It has been shown that the process of equalization of the concentration with time is exponential in character. The characteristic equalization time has been computed using the theory of turbulent diffusion. Theoretical results describe experimental regularities with an accuracy of about 10%. The value of the coefficient of turbulent diffusion for different configurations of flows in the chamber has been obtained from a comparison of experimental and calculated results.
Lattice vibrations and electronic transitions in the rare-earth metals: Praseodymium under pressure
(2004)
Praseodymium was investigated by Raman spectroscopy under pressure. A negative pressure shift of the E2g mode is observed in the dhcp phase, which indicates that the initial structural sequence hcp→Sm−type→dhcp→fcc as a whole in the regular lanthanides is associated with a softening of this mode. The pressure response of the phonon modes, observed in the monoclinic and α-uranium phases, where 4f bonding becomes important, is characteristic for anisotropic bonding properties.
The iSign project started in 2000 as a web-based laboratory setting for students of electrical engineering. In the meantime it has broadened into a heterogeneous learning environment offering learning material, adaptive user settings and access to a simulation tool. All these offerings can be accessed via web and wireless by different clients, such as PCs, PDAs and mobile phones. User adaptive systems offer unique and personalised environment for every learner and therefore are a very important aspect of modern e-learning systems. The iSign project aims to personalise the content structure based on the learner's behaviour, content pattern, policies, and system environment. The second aspect of the recent research and development within this project is the generation of suitable content and presentation for different clients. This generation is based additionally on the user preferences in order to obtain the desirable presentation for a given device. New, valuable features are added to the mobile application, empowering the user not only to control the simulation process with his mobile device but also to input data, view the simulation's output and evaluate the results. Experiences with students have helped to improve functionality and look-and-feel whilst using the iSign system. Our goal is to provide unconstrained, continuous and personalised access to the laboratory settings and learning material everywhere and at anytime with different devices.
This paper explores the potential of an m-learning environment by introducing the concept of mLab, a remote laboratory environment accessible through the use of handheld devices.
We are aiming to enhance the existing e-learning platform and internet-assisted laboratory settings, where students are offered in-depth tutoring, by providing compact tuition and tools for controlling simulations that are made available to learners via handheld devices. In this way, students are empowered by having access totheir simulations from any place and at any time.
The establishment of a software tool chain among requirements management tools, black box test approach tool CTE XL and RTRT is proposed in this paper. The use of Classification Tree Method ensures the reduction in the number of test cases and promises an increased efficiency when testing. The traceability of test cases and requirements is guaranteed by the established software tool chain with well defined interfaces. As the experimental results point out, a better test coverage can be achieved. Future work can be based on automatic generation of init and expected values for testing, requiring no interference from a software quality engineer. In conclusion, the tasks that need to be performed by the software quality engineers is to define the black box test cases using CTM/CTE XL, import the requirements from the requirements management tools, import the XML file to test tool RTRT. By giving the initial and expected values the testing can be performed in a comfortable way.
Nowadays the processing power of mobile phones, Smart phones and PDA is increasing, as well as the transmission bandwidth. Nevertheless there is still the need to reduce the content and the need of processing the data. Proposals and solutions for dynamic reduction of the transmitted content will be discussed. For that, device specific properties will be taken into account, aiming at reducing the need of processing power at the client side to display the 3D Virtual Reality data. Therefore, well known technologies like data compression are combined with new approaches to achieve the goal of adaptive content transmission. For device dependant reduction of processing power the data has to be pre-processed at the server side or the server itself has to take over functionality of weak mobile devices.
Electronic pills, smart capsules or miniaturized microsystems swallowed by human beings or animals for various biomedical and diagnostic applications are growing rapidly in the last years. This paper searched out the important existing electronic pills in the market and prototypes in research centers. Further objective of this research is to develop a technology platform with enhanced feature to cover the drawback of most
capsules. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA.
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
A new electronic capsule with bidirectional communication system is being developed for multi-task application. The capsule is designed to be a platform for medical assistant application inside the body. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
A new, small, and optimized for low power processor core named SIRIUS has been developed, simulated, synthesized to a netlist and verified. From this netlist, containing only primitives like gates and flip-flops, a mapping to an ASIC - or FPGA technology can easily be done with existing synthesizer tools, allowing very complex SOC designs with several blocks. Emulation via FPGA can be done on already simple setups and cheap hardware because of the small core size. The performance is estimated 50 MIPS on Cyclone II FPGA and about 100 MIPS on a 0.35 CMOS 5M2P technology with 4197 primitives used for the core, including a 16 x 16 multiplier. An example design of the ASIC for an electronic ePille device currently in development is shown.
To provide proper solutions to the problem of device dependant content delivery, a fine categorization of the application target devices is needed. Earlier attempts provided two different presentations for desktop and mobile platforms. The mobile platform presentation was divided into three categories, based on a general classification (PDA, Smartphone or mobile phone). In order to improve the on mobile device presentation a finer categorization is introduced. In this paper, our focus is to clarify the concept of this more flexible presentation module, in which the delivered content depends on the efficiency of the device based on a selected set of capabilities.
Design of next-generation cdma using orthogonal complementary codes and offset stacked spreading
(2007)
This article presents an innovative code-division multiple access system architecture that is based on orthogonal complementary spreading codes and time-frequency domain spreading. The architecture has several advantages compared to conventional CDMA systems. Specifically, it offers multiple-access-interference-free operation in AWGN channels, reduces co-channel interference significantly, and has the potential for higher capacity and spectral efficiency than conventional CDMA systems. This is accomplished by using an "offset stacked" spreading modulation technique followed by quadrature amplitude modulation, which optimizes performance in a fading environment. This new spreading modulation scheme also simplifies the rate matching algorithms relevant for multimedia services and IP-based applications.
This paper presents a multicarrier code-division multiple-access (CDMA) system architecture that is based on complete complementary orthogonal spreading codes. The architecture has several advantages as compared to conventional CDMA systems. Specifically, it offers multiple-access interference-free operation in additive white Gaussian noise channels, reduces cochannel interference significantly, and has the potential of higher capacity and spectral efficiency than conventional CDMA systems. This is accomplished by using an ldquooffset stackedrdquo spreading modulation technique. To maintain good performance in the presence of fading, the offset stacked modulator is followed by a quadrature-amplitude modulation map, which is designed to optimize performance in a fading environment. This new modulation scheme also simplifies the rate-matching algorithms that are relevant for multimedia services and Internet Protocol-based applications.
A new miniaturized capsule with 32bit processor and bidirectional communication system is being developed for multitask application. The capsule is designed to be a platform for medical assistant application inside the body. The processor core SIRIUS has been developed, simulated, synthesized to a netlist and verified. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25 mm. The system is designed, simulated, emulated on FPGA, and routed in AMIS Technology.
A new approach of continuous phase QPSK Band-Pass modulation technique is being developed as enhancement to the QPSK modulation scheme for inductive data transmission (NFC). The modulation is based on Gaussian filtering of the phase transition from one state to the other rather than discontinuity in phase shift. The carrier is based on low frequency 115 KHz suitable for human body energy penetration due to its large skin-depth and lower inductive power attenuation. The complete signal processing is done digitally, external coil and capacitor is used for transceiver interface. The telemetry assists a smart pill swallowed by human being to trigger an actuator for drug delivery, record temperature, or perform diagnostic task inside the body. The smart pill includes 32bit processor, 16 Kbyte memory, temperature sensor, telemetry unit, and additional external peripheries. The complete system is designed, embedded in one SoC, and realized on ASIC with chip-area less than 14 mm<sup>2</sup>.
The mobile devices related industries are subject to rapid change, driven by technological advances and dynamic consumer behaviour. Hence, the understanding of the mobile devices markets is an important step in the analysis phase of mobile applications development. In this paper, a brief description of the different markets is introduced followed by an analysis of the main features of the markets leaders' devices which are important in the development process of mobile web applications. Finally, approaches are proposed to deal with the mobile devices diversity.
A theoretical description is given for the propagation of surface acoustic wave pulses in anisotropic elastic media subject to the influence of nonlinearity. On the basis of nonlinear elasticity theory, an evolution equation is presented for the surface slope or the longitudinal surface velocity associated with an acoustic pulse. It contains a non-local nonlinearity, characterized by a kernel that strongly varies from one propagation geometry to another due to the anisotropy of the substrate. It governs pulse shape evolution in homogeneous halfspaces and the shapes of solitary surface pulses that exist in coated substrates. The theory describing nonlinear Rayleigh-type surface acoustic waves is extended in a straightforward way to surface waves that are localized at a one-dimensional acoustic waveguide like elastic wedges.
This paper shows the results of the evaluation of two sets of mobile web design guidelines concerning mobile learning. The first set of guidelines is concerned with the usage of text on mobile device screens. The second set is concerned with the usage of images on mobile devices. The evaluation is performed by eye tracking (objective) as well as questionnaires and interviews (subjective) respectively.
In the recent two years the authors have developed a light weight and low power flight control system for model helicopters consisting of an attitude and heading reference system (AHRS), a navigator (INS) augmented with GPS, barometric altitude sensor and a magnetic sensor, a flight control computer (FCC) and bidirectional ground data links. The system has been tested on a commercial stunt flight model helicopter. The AHRS consists of three MEMS-gyros, two 2-axis MEMS accelerometers and a microcontroller performing the required sensor compensation and data processing to generate attitude angles and true rate and acceleration data of the flying platform. The heading angle is augmented with a 2-axis magnetic sensor. The AHRS is stunt flight capable. The INS integrates the acceleration data to obtain velocity and position data. All data are calculated in both the helicopter and the local earth frame with 50 Hz rate. The algorithm is augmented with GPS data for the lateral movement and with a barometric altitude sensor for the vertical movement. The barometric data are compensated for air pressure changes due to the helicopter main rotor. The FCC contains a set of control loops in order to stabilize the helicopter in all axis and to perform commanded velocity and position tasks. The sampling rate for the control loops is again 50 Hz allowing flight control with high bandwidth. Various safety features are implemented in the software. The bidirectional data link is based on a 2.4 GHz Bluetooth Class I RF-link with a 115 kbaud data rate. A dipole antenna is used on the helicopter, an automatically tracking patch antenna is used on the ground. For commanded velocity flight a standard 35 MHz RF-link is used. For data sampling, monitoring and mode control a laptop is used on the ground. Several operating modes are implemented ranging from commanded velocity flight to simple automatic stunt flight according to predefined flight tracks. The model helicopter is an ALIGN TREX 600 with 3 kg flight mass and a brushless electric motor. The rotor diameter is 1.40 m. The helicopter is able to carry a payload which mass depends on the size of the installed LiPo-cells and the purpose of the flight mission. The system has been tested in quite a few flight tests and missions. The helicopter is controlled safely up to wind loads of at least 5 Beaufort - 6 Beaufort. Data and video captures will be presented. If permission is granted, a demonstration flight will be performed on the premises of the conference.
This paper presents an enhancement on QPSK modulation technique for near field communication (NFC). The enhanced modulation is based on continuous-phase QPSK with Gaussian filtering during switch from one phase to the other. Signal processing is done digitally with minimum external discrete components for air interface. The telemetry system can be used to assist a smart capsule (slave) that can be swallowed to establish data communication with external device (master). The system is designed, simulated, and emulated on FPGA showing 20 dB attenuation on side-lobes of the spectrum.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2009. It focuses on two distinctive features of the team: decisions making using extended behavior networks and its software architecture and implementation in Java to open the simulation for the Java community.
Innovative technologies and concepts will emerge as we move towards a more dynamic, service-based, market-driven infrastructure, where energy efficiency and savings can be facilitated by interactive distribution networks. A new generation of fully interactive Information and Communication Technologies (ICT) infrastructure has to be developed to support the optimal exploitation of the changing, complex business processes and to enable the efficient functioning of the deregulated energy market for the benefit of citizens and businesses. The architecture of such distributed system landscapes must be designed and validated, standards need to be created and widely supported, and comprehensive, reliable IT applications will need to be implemented. The collaboration between a smart house and a smart grid is a promising approach which, with the help of ICT can fully unleash the capabilities of the smart electricity network.
This paper discusses a technological solution to real-time road transportation optimization using a commercial multi-agent based system, LS/ATN, which has been proven through real-world deployment to reduce transportation costs for both small and large fleets in the full and part load business. Subsequent to describing the real-time optimization approach, we discuss how the platform is currently evolving to accept live data from vehicles in the fleet in order to improve optimization accuracy. A selection of the predominant pervasive technologies available today for enhancing intelligent route optimization is described.
The developed solution enables the presentation of animations and 3D virtual reality (VR) on mobile devices and is well suited for mobile learning, thus creating new possibilities in the area of e-learning worldwide. Difficult relations in physics as well as intricate experiments in optics can be visualised on mobile devices without need for a personal computer.
In short-reach connections, large-diameter multimode fibres allow for robust and easy connections. Unfortunately, their propagation properties depend on the excitation conditions. We propose a launching technique using a fibre stub that can tolerate fabrication tolerances in terms of tilts and off-sets to a large extent. A study of the influence of displaced connectors along the transmission link shows that the power distributions approach a steady-state power distribution very similar to the initial distribution established by the proposed launching scheme.
The idea of this game is to use a flashcard system to create a short story in a foreign language. The story is developed by a group of people by exchanging sentences via a flashcard system. This way, people can learn from each other without fear of making mistakes because the group members are anonymous.
There are some existing Java benchmarks, application benchmarks as well as micro benchmarks or mixture both of them,such as: Java Grande, Spec98, CaffeMark, HBech, etc. But none of them deal with behaviors of multi tasks operating systems. As a result, the achieved outputs are not satisfied for performance evaluation engineers. Behaviors of multi tasks operating systems are based on a schedule management which is employed in these systems. Different processes can have different priority to share the same resources. The time is measured by estimating from applications started to it is finished does not reflect the real time value which the system need for running those programs. New approach to this problem should be done. Having said that, in this paper we present a new Java benchmark, named FHOJ benchmark, which directly deals with multi tasks behaviors of a system. Our study shows that in some cases, results from FHOJ benchmark are far more reliable in comparison with some existing Java benchmarks.
Flashcards are a well known and proven method to learn and memorise. Such a way of learning is perfectly suited for “learning on the way,” but carrying all the flashcards could be awkward. In this scenario, a mobile device (mobile phone) is an adequate solution. The new mobile device operating system Android from Google allows for writing multimedia-enriched applications.
“Today’s network landscape consists of quite different network technologies, wide range of end-devices with large scale of capabilities and power, and immense quantity of information and data represented in different formats” [9]. A lot of efforts are being done in order to establish open, scalable and seamless integration of various technologies and content presentation for different devices including mobile considering individual situation of the end user. This is very difficult because various kinds of devices used by different users or in different times/parallel by the same user which is not predictable and have to be recognized by the system in order to know device capabilities. Not only the devices but also Content and User Interfaces are big issues because they could include different kinds of data format like text, image, audio, video, 3D Virtual Reality data and upcoming other formats. Language Learning Game (LLG) is such an example of a device independent application where different kinds of devices and data formats, as a content of a flashcard is used for a collaborative learning. The idea of this game is to create a short story in a foreign language by using mobile devices. The story is developed by a group of participants by exchanging sentences/data via a flashcard system. This way the participants can learn from each other by knowledge sharing without fear of making mistakes because the group members are anonymous. Moreover they do not need a constant support from a teacher.
The application relates to an electronic pill for dispensing a substance, in particular a drug, in a human or animal body in a controllable manner, said electronic pill having a housing (3) in which the substance (17) to be dispensed is accommodated and in which a dispensing opening (47) for dispensing the substance (17) is provided, wherein the substance (17) can be subjected to a predetermined pressure in order to be dispensed from the housing (3), having an electronic control unit (53, 59, 61, 63), and having a valve unit (33) which is arranged in the course of a dispensing path and can be moved from an open position to a closed position by the control unit (53, 59, 61, 63). In the housing (3), a throttle section (45) is provided in the course of the dispensing path for the substance (17) to be dispensed.
The Institute of Applied Research Offenburg is working in the field of autonomous data loggers since many years. In collaboration with industry, a new RFID based active sensor data logger for continuous recording of temperature has been developed and is now manufactured in mass production. Compared to existing systems, an unusual large data memory is integrated, which can be used via a simplified file system in a flexible way. The system will be used to accompany and monitor temperature sensitive goods of high value. The transponder is the first member of a new class of logging devices, the smallest will be not larger than a 2 Euro-coin with a fully integrated ASIC frontend.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2010. While last year’s TDP focused on decisions making using extended behavior networks and on its software architecture and implementation in this year we describe the tool set that was created for RoboCup 3D. It contians a GUI for agent- and world state visualization, for evaluation of localization algorithms and benchmarks in general, a visual editor for Extended Behavior Networks creation and debugging, a live movement tool to interact with the joints and finally a tool for editing behavior motor files.
Termination of atrial flutter (AFL) is not possible in all AFL patients (P) with transesophageal left atrial pacing (TLAP) with undirected electrical pacing field (EPF) and high atrial pacing threshold. Purpose of the study was to evaluate bipo-lar transesophageal left atrial electrocardiography (TLAE) and TLAP with directed EPF for evaluation and termination of AFL with and without simultaneous transesophageal echocardiography (TEE).
Methods: AFL P were analysed using either a TO electrode with one cylindrical (CE) and three or seven hemispherical electrodes (HE) or TEE electrode with four HE (Osypka, Rheinfelden, Germany). Burst TLAP cycle length was between 200msand 50ms.
Results: AFL cycle length was 233±30 ms with mean ventricular cycle length of 540±149 ms. AFL could be terminated by rapid bipolar TLAP with directed EPF using HE-HE and CE-HE with induction of atrial fibrillation (AF), induction of AF and spontaneous conversion to sinus rhythm and direct conversion to sinus rhythm. Directed EPF was simulated with finite element method.
Conclusions: AFL can be evaluated by bipolar TLAE. AFL can be terminated with rapid TLAP with directed EPF with and without simultaneous TEE. Bipolar TLAE with rapid TLAP is a safe, simple and useful method for evaluation and termination of AFL.
Cardiac resynchronisation therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with interventricular conduction delay (IVCD). The aim of the study was to evaluate transesophageal IVCD and left ventricular (LV) pacing with directed electrical pacing field (EPF) in HF patients.
Methods: HF patients were analysed with bipolar transesophageal LV electrocardiogram recording and LV pacing with constant voltage stimulus output, 4 ms stimulus duration, distal cylindrical electrode (CE) and seven 6 mm hemispherical electrodes (HE) with 15 mm electrode distance (TO, Dr. Osypka, Rheinfelden, Germany).
Results: LV electrocardiogram recording with HE-HE and CE-HE evaluated a mean IVCD of 79.9 ± 36.7 ms. Directed EPF with CE-HE and HE-HE allowed LV VAT (n=12) and LV D00 pacing (n=5) with a mean effective capture output of 97.35 ± 6.64 V. In 15 responders with IVCD of 87 ± 33 ms arterial pulse pressure (PP) increased from 65 ± 24 mmHg to 79 ± 27 mmHg (p < 0.001). EPF was simulated with finite element method.
Conclusions: Transesophageal LV electrocardiography and directed EPF pacing with CE and HE allowed the evaluation of IVCD and PP to select patients for BV pacing.
AV delay (AVD) optimization can improve hemodynamics and avoid nonresponding to cardiac resynchronization therapy (CRT). AVD can be approximated by the sum of the individual implant-related interatrial conduction interval and a mean electromechanical interval of about 50ms. We searched for methods to facilitate automatic, implant-based AV delay optimization. In 25 patients (19m, 6f, age: 65±8yrs.) with Medtronic Insync III Marquis CRT-D series systems and left ventricular electrode at lateral or posterolateral wall, we determined interatrial conduction intervals by telemetric left ventricular tip versus superior vena cava coil electrogram (LVCE). Compared with esophageal measurements, the duration of optimal AV delay by LVCE showed good correlation (k=0.98, p=0.01) with a difference of 1.5±4.9ms, only. Therefore, LVCE is feasible to determine interatrial conduction intervals in order to automate AV delay optimization in CRT-D pacing promising increased accuracy compared to other algorithms.
AV delay (AVD) optimization is mandatory in cardiac resynchronization (CRT) for heart failure. Several time consuming methods exist. We initialized development of left-atrial electrogram (LAE) feature for Biotronik ICS3000 programmer. It can be utilized to approximate optimal AV delay in CRT patients with pacing systems irrespective of make and model. Using this feature, we studied the share of interatrial conduction intervals (IACT) on individual echo AVD in 45 CRT patients (34m, 11f, mean age 69±6yrs.). The percentage of IACT on optimal echo AVD resulted in44.5±22.1% for VDD and 70.7±10.9% for DDD operation. In all patients, optimal echo AVDs exceeded the individual IACT by a duration of 52.5±33.3ms (p<0.001), at mean. Therefore, if AV delay optimization is not possible or not practicable in CRT patients, AVD should be approximated by individually measuring IACT and adding about 50ms.
The invention relates to a multi railed track vehicle, designed with a conducting connection of pairs of rails with a connection resistance reducing agent for reducing the connection resistance to the rail. According to the invention, the connection resistance reducing agent is designed to generate arcs between at least one rail and the track vehicle.
This paper gives an overview of the implementation of an Active Noise Control system on the TMS320C6713 Digital Signal Processor from Texas Instruments in the Digital Signal Processing Lab at Hochschule Offenburg, Germany. This system is implemented considering some non-ideal environmental conditions on a real system instead of being limited to computer simulations. Changes over time on the physical acoustical path as well as reverberation and variation on the power of the reference signal can strongly degrade the performance of the system or even lead to instability. In order to try to minimize these effects, the Active Noise Control system was designed to support a fast and easy implementation and evaluation of different algorithms on the DSP in real-time. In Section 1 a brief introduction about active noise control system is given and in section 2 the basic algorithm is described. In section 3 the implementation of the system is described and in section 4 some final considerations are given.
In their famous work on prospect theory Kahneman and Tversky have presented a couple of examples where human decision making deviates from rational decision making as defined by decision theory. This paper describes the use of extended behavior networks to model human decision making in the sense of prospect theory. We show that the experimental findings of non-rational decision making described by Kahneman and Tversky can be reproduced using a slight variation of extended behavior networks.
Using guideline parameters for indication of cardiac resynchronization therapy (CRT), only about two thirds of the patients improve clinically. Unfortunately both, surface ECG and echo are uncertain to predict CRT response. To better characterize cardiac desynchronization in heart failure, interventricular (IVCD) and intra-leftventricular conduction delays (ILVCD) were measured by esophageal left ventricular electrogram (LVE). Recordings in 43 CRT patients (34m, 9f, age: 64.7 ± 9.5yrs) evidenced only weak correlation between IVCD and QRS of 0.53 and between ILVCD and QRS of 0.33. This demonstrated that QRS duration is not a reliable indicator of desynchronization. Therefore, the study resulted into development of LVE feature for a programmer with implant support device. It can be used interoperatively to guide the left ventricular electrode location in order to increase responder rate in CRT.
Mobile learning (m-learning) can be considered as a new paradigm of e-learning. The developed solution enables the presentation of animations and 3D virtual reality (VR) on mobile devices and is well suited for mobile learning. Difficult relations in physics as well as intricate experiments in optics can be visualised on mobile devices without need for a personal computer. By outsourcing the computational power to a server, the coverage is worldwide.
We report the fabrication and characterization of glucose-tolerant Raney-platinum cathodes for oxygen reduction in potentially implantable glucose fuel. Fabricated by extraction of aluminum from 1 μm thin platinum–aluminum bi-layers annealed at 300 °C, the novel cathodes show excellent resistance against hydrolytic and oxidative attack. This renders them superior over previous cathodes fabricated from hydrogel-bound catalyst particles. Annealing times of 60, 120, and 240 min result in approximately 400–550 nm thin porous films (roughness factors ∼100–150), which contain platinum and aluminum in a ratio of ∼9:1. Aluminum release during electrode operation can be expected to have no significant effect on physiological normal levels, which promises good biocompatibility. Annealing time has a distinct influence on the density of trenches formed in the cathode. Higher trench densities lead to lower electrode potentials in the presence of glucose. This suggests that glucose sensitivity is governed by mixed potential formation resulting from oxygen depletion within the trenches. During performance characterization the diffusion resistance to be expected from tissue capsule formation upon electrode implantation was taken into account by placing a membrane in front of the cathode. Despite the resulting limited oxygen supply, cathodes prepared by annealing for 60 min show more positive electrode potentials than previous cathodes fabricated from hydrogel-bound activated carbon. Compared to operation in phosphate buffered saline containing 3.0 mM glucose, a potential loss of approximately 120 mV occurs in artificial tissue fluid. This can be reduced to approximately 90 mV with a protective Nafion layer that is easily electro-coated onto the Raney-platinum film.
We present a novel fabrication route yielding Raney-platinum film electrodes intended as glucose oxidation anodes for potentially implantable fuel cells. Fabrication roots on thermal alloying of an extractable metal with bulk platinum at 200 °C for 48 h. In contrast to earlier works using carcinogenic nickel, we employ zinc as potentially biocompatible alloying partner. Microstructure analysis indicates that after removal of extractable zinc the porous Raney-platinum film (roughness factor ∼2700) consists predominantly of the Pt3Zn phase. Release of zinc during electrode operation can be expected to have no significant effect on physiological normal levels in blood and serum, which promises good biocompatibility. In contrast to previous anodes based on hydrogel-bound catalyst particles the novel anodes exhibit excellent resistance against hydrolytic and oxidative attack. Furthermore, they exhibit significantly lower polarization with up to approximately 100 mV more negative electrode potentials in the current density range relevant for fuel cell operation. The anodes’ amenability to surface modification with protective polymers is demonstrated by the exemplary application of an approximately 300 nm thin Nafion coating. This had only a marginal effect on the anode long-term stability and amino acid tolerance. While in physiological glucose solution after approximately 100 h of operation gradually increasing performance degradation occurs, rapid electrode polarization within 24 h is observed in artificial tissue fluid. Optimization approaches may include catalyst enhancement by adatom surface modification and the application of specifically designed protective polymers with controlled charge and mesh size.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2011. While last year’s TDP focused on the tool set created for 3D simulation in this year we describe the further improvement in this tools as well as some new features we implemented focusing on heterogeneous robot models which seem to be used in RoboCup 2012.
An additional tool was written to simply generate situation-dependent strategies. Furthermore some tools, described last year, are now integrated in one single GUI to easy things up.
Introduction: Patient selection for cardiac resynchronization therapy (CRT) requires quantification of left ventricular conduction delay (LVCD). After implantation of biventricular pacing systems, individual AV delay (AVD) programming is essential to ensure hemodynamic response. To exclude adverse effects, AVD should exceed individual implant-related interatrial conduction times (IACT). As result of a pilot study, we proposed the development of a programmer-based transoesophageal left heart electrogram (LHE) recording to simplify both, LVCD and IACT measurement. This feature was implemented into the Biotronik ICS3000 programmer simultaneously with 3-channel surface ECG.
Methods: A 5F oesophageal electrode was perorally applied in 44 heart failure CRT-D patients (34m, 10f, 65±8 yrs., QRS=162±21ms). In position of maximum left ventricular deflection, oesophageal LVCD was measured between onsets of QRS in surface ECG and oesophageal left ventricular deflection. Then, in position of maximum left atrial deflection (LA), IACT in VDD operation (As-LA) was calculated by difference between programmed AV delay and the measured interval from onset of left atrial deflection to ventricular stimulus in the oesophageal electrogram. IACT in DDD operation (Ap-LA) was measured between atrial stimulus and LA..
Results: LVCD of the CRT patients was characterized by a minimum of 47ms with mean of 69±23ms. As-LA and Ap-LA were found to be 41±23ms and 125±25ms, resp., at mean. In 7 patients (15,9%), IACT measurement in DDD operation uncovered adverse AVD if left in factory settings. In this cases, Ap-LA exceeded the factory AVD. In 6 patients (13,6%), IACT in VDD operation was less than or equal 10ms indicating the need for short AVD.
Conclusion: Response to CRT requires distinct LVCD and AVD optimization. The ICS3000 oesophageal LHE feature can be utilized to measure LVCD in order to justify selection for CRT. IACT measurement simplifies AV delay optimization in patients with CRT systems irrespective of their make and model.
Introduction: To simplify AV delay (AVD) optimization in cardiac resynchronization therapy (CRT), we reported that the hemodynamically optimal AVD for VDD and DDD mode CRT pacing can be approximated by individually measuring implant-related interatrial conduction intervals (IACT) in oesophageal electrogram (LAE) and adding about 50ms. The programmer-based St Jude QuickOpt algorithm is utilizing this finding. By automatically measuring IACT in VDD operation, it predicts the sensed AVD by adding either 30ms or 60ms. Paced AVD is strictly 50ms longer than sensed AVD. As consequence of those variations, several studies identified distinct inaccuracies of QuickOpt. Therefore, we aimed to seek for better approaches to automate AVD optimization.
Methods: In a study of 35 heart failure patients (27m, 8f, age: 67±8y) with Insync III Marquis CRT-D systems we recorded telemetric electrograms between left ventricular electrode and superior vena cava shock coil (LVtip/SVC = LVCE) simultaneously with LAE. By LVCE we measured intervals As-Pe in VDD and Ap-Pe in DDD operation between right atrial sense-event (As) or atrial stimulus (Ap), resp., and end of the atrial activity (Pe). As-Pe and Ap-Pe were compared with As-LA an Ap-LA in LAE, respectively.
Results: End of the left atrial activity in LVCE could clearly be recognized in 35/35 patients in VDD and 29/35 patients in DDD operation. We found mean intervals As-LA of 40.2±24.5ms and Ap-LA of 124.3±20.6ms. As-Pe was 94.8±24.1ms and Ap-Pe was 181.1±17.8ms. Analyzing the sums of As-LA + 50ms with duration of As-Pe and Ap-LA + 50ms with duration of Ap-Pe, the differences were 4.7±9.2ms and 4.2±8.6ms, resp., only. Thus, hemodynamically optimal timing of the ventricular stimulus can be triggered by automatically detecting Pe in LVCE.
Conclusion: Based on minimal deviations between LAE and LVCE approach, we proposed companies to utilize the LVCE in order to automate individual AVD optimization in CRT pacing.
In-vivo and in-vitro comparison of implant-based CRT optimization - What provide new algorithms?
(2011)
Introduction: In cardiac resynchronization therapy (CRT), individual AV delay (AVD) optimization can effectively increase hemodynamics and reduce non-responder rate. Accurate, automatic and easily comprehensible algorithms for the follow-up are desirable. QuickOpt is the first attempt of a semi-automatic intracardiac electrogram (IEGM) based AVD algorithm. We aimed to compare its accuracy and usefulness by in-vitro and in-vivo studies.
Methods: Using the programmable ARSI-4 four-chamber heart rhythm and IEGM simulator (HKP, Germany), the QuickOpt feature of an Epic HF system (St. Jude, USA) was tested in-vitro by simulated atrial IEGM amplitudes between 0.3 and 3.5mV during both, manual and automatic atrial sensing between 0.2 and 1.0mV. Subsequently, in 21 heart failure patients with implanted biventricular defibrillators, QuickOpt was performed in-vivo. Results of the algorithm for VDD and DDD stimulation were compared with echo AV delay optimization.
Results: In-vitro simulations demonstrated a QuickOpt measuring accuracy of ± 8ms. Depending on atrial IEGM amplitude, the algorithm proposed optimal AVD between 90 and 150ms for VDD and between 140 and 200ms for DDD operation, respectively. In-vivo, QuickOpt difference between individual AVD in DDD and VDD mode was either 50ms (20pts) or 40ms (1pt). QuickOpt and echo AVD differed by 41 ± 25ms (7 – 90ms) in VDD and by 18 ± 24ms (17-50ms) in DDD operation. Individual echo AVD difference between both modes was 73 ± 20ms (30-100ms).
Conclusion: The study demonstrates the value of in-vitro studies. It predicted QuickOpt deficiencies regarding IEGM amplitude dependent AVD proposals constrained to fixed individual differences between DDD and VDD mode. Consequently, in-vivo, the algorithm provided AVD of predominantly longer duration than echo in both modes. Accepting echo individualization as gold standard, QuickOpt should not be used alone to optimize AVD in CRT patients.
Existing approaches solving multi-vehicle pickup and delivery problems with soft time windows typically use common benchmark sets to verify their performance. However, there is a gap from these benchmark sets to real world problems with respect to instance size and problem complexity. In this paper we show that a combination of existing approaches together with improved heuristics is able to deal with the instance sizes and complexity of real world problems. The cost savings potential of the heuristics is compared to human dispatching plans generated from the data of a European carrier.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.
Electrical velocimetry to optimize VV delay in biventricular VVIR and DDD pacing for heart failure
(2011)
Introduction: VV delay (VVD) is the only parameter to hemodynamically optimize cardiac resynchronization therapy (CRT) for patients with atrial fibrillation (AF). Electrical velocimetry (EV) has been established to monitor thoracic electrical conductivity and to calculate hemodynamic surrogate parameters. We compared the response of this method to hemodynamic parameter changes between CRT patients with sinus rhythm (SR) and patients with AF.
Methods: VVD was individualized in 17 CRT patients in SR (12m, 5f, 67.0±7.2yrs.) after echo AV delay optimization and in 11 CRT patients in AF (10m, 1f, 69.8±9.6yrs.) using the Aesculon Cardiovascular Monitor (Osypka Medical, Berlin, Germany). Serial 30s EV recordings were accomplished, decreasing the VVD stepwise by 10ms from +60ms to -60ms between right and left ventricular stimulus. Optimal VVD was determined by the maximum of at least two of the three averaged parameters stroke volume (SV), cardiac output (CO) and cardiac index (CI). The response of SV, CO and CI was tested comparing their values in optimal VVD and suboptimal VVD. Suboptimal VVD was defined by optimal VVD±20ms.
Results: In all 28 patients in SR and AF, EV recordings resulted in optimal VVD. Between suboptimal and optimal mean VVD of 18.6±30.8ms between left and right ventricular stimulus, SV increased by 7.2±6.8%, CO by 7.8±7.2% and CI by 10.0±13.3% (all p<0.02). In the SR group with VVD of 18.8± 29.6ms, SV increased by 4.6±2.9%, CO by 5.0±2.9% and CI by 4.9±2.9% (all p<0.02). In the AF group with VVD of 18.2±4.0ms, SV increased by 10.4±8.9%, CO by 11.3±9.5% and CI by 16.4±18.2% (all p<0.02). Significant differences were not found between optimal VVD in SR and AF patients.
Conclusion: EV is a feasible serial method to individualize VVD in DDD and VVIR pacing for heart failure. Its response to hemodynamic changes demonstrates the value of EV for VVD fine-tuning.
Introduction: Cardiac resynchronization therapy (CRT) with left ventricular (LV) pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation and reduced LV ejection fraction (EF). The aim of this study was to test the utilization of the transesophageal approach to measure arterial pulse pressure (PP) during LV pacing and electrical interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 32 HF patients (age 64 ± 10 years; 5 females, 27 males) with New York Heart Association (NYHA) class 2.8 ± 0.6, 27 ± 11 % LV EF and 155 ± 35 ms QRS duration were analysed with semi-invasive left cardiac pacing and electrocardiography. Esophageal TO8 Osypka catheter of 10.5 F diameter was perorally applied to the esophagus and placed in the position of maximum left atrial (LA) deflection and maximum LV deflection to measure PP with VAT or D00 pacing modes.
Results: Temporary transesophageal LV pacing was possible with VAT mode (n=16) and D00 mode (n=16) in all patients. In 15 Δ-PP-responders, PP was higher during LV pacing on than LV pacing off (78.3 ± 26.6 versus 65.9 ± 23.7 mmHg, P < 0.001) and NYHA class improved from 3.1 ± 0.35 to 2.1 ± 0.35 (P < 0.001) during 29 ± 26 month biventricular (BV) pacing follow-up (6 Medtronic and 9 Boston BV pacing devices). In 17 Δ-PP-non-responders, PP was not higher during LV pacing on than LV pacing off (61.5 ± 23.9 versus 60.9 ± 23.5 mmHg, P = 0.066). IVCD was significant longer in Δ-PP-responders than in Δ-PP-non-responders (87 ± 33 ms versus 37± 29 ms, P < 0.001).
Conclusion: Semi-invasive transesophageale LA and LV pacing with D00 and VAT mode and LV electrogram recording may be useful techniques to predict CRT improvement.
Home Care Applications and Ambient Assisted Living become increasingly attractive. This is caused as well by market pull, as the number of elderly people grows monotonously, as well as by technology push, as technological advances and attractive products pave the way to economically advantageous offerings. However, in real-life applications, a significant number of challenges remain. Those include seamless communication between products from different supplier, due to the lack of sufficiently standardized solutions, energy budgets, and scalability of solutions. This paper presents the experience from the InCASA project (Integrated Network for Completely Assisted Senior Citizen's Autonomy), where architectures for heterogeneous physical and logical communication flows are examined.
The efficient support of Hardwae-In-theLoop (HIL) in the design process of hardwaresoftware-co-designed systems is an ongoing challenge. This paper presents a network-based integration of hardware elements into the softwarebased image processing tool „ADTF“, based on a high-performance Gigabit Ethernet MAC and a highly-efficient TCP/IP-stack. The MAC has been designed in VHDL. It was verified in a SystemCsimulation environment and tested on several Altera FPGAs.
Introduction: Cardiac resynchronisation therapy (CRT) with atrioventricular (AV) and interventricular (VV) optimized biventricular pacing (BV) is an established therapy for heart failure (HF) patients. The aim of the study was to compare AV and VV delay optimization with cardiac output (CO), cardiac index (CI), contractility index (IC) and acceleration index (ACI) impedance cardiographic (ICG) methods in CRT.
Methods: 15 HF patients (age 66 ± 10 years; 2 females, 13 males) in New York Heart Association (NYHA) class 3.1 ± 0.4, left ventricular (LV) ejection fraction 21.3 ± 7.8 % and QRS duration 176.1 ± 31.7 ms underwent AV and VV delay optimization with CO, CI, IC and ACI (Cardioscreen ®, Medis GmbH, Ilmenau, Germany) at different AV and VV delay BV pacing settings versus right ventricular (RV) pacing one day after implantation of a CRT device.
Results: Optimal AV delay after atrial sensing was 108.6 ± 20.3 ms (n=14) and optimal AV delay after atrial pacing 190 ± 14.1 ms (n=2) with AV delay range from 80 ms to 200 ms. Optimal VV delay was -12.3 ± 25.9 ms left ventricular before RV pacing. RV versus BV pacing mode resulted in improvement of CO from 3.4 ± 1.2 l/min to 4.4 ± 1.4 l/min (p<0.001), CI from 1.8 ± 0.64 l/min/m² to 2.4 ± 0.78 l/min/m² (p<0.001), IC from 0.028 ± 0.011 1/s to 0.036 ± 0.013 1/s (p<0.001) and ACI from 0.667 ± 0.227 1/s² to 0.834 ± 0.282 1/s² (p<0.002). During 34 ± 26 month BV pacing, the NYHA class improved from 3.1 ± 0.4 to 2.1 ± 0.4 (p<0.001).
Conclusion: AV and VV delay optimized BV pacing acutely improve hemodynamic parameters of transthoracic ICG and their NYHA class during long-term follow-up. ICG may be a simple and useful technique to optimize AV and VV delay in CRT.
Introduction: Cardiac resynchronisation therapy (CRT) with atrioventricular (AV) and interventricular (VV) optimized biventricular pacing (BV) is an established therapy for heart failure (HF) patients with electrical interventricular conduction delay (IVCD). The aim of the study was to compare AV and VV delay optimization with cardiac output (CO) and acceleration index (ACI) impedance cardiographic (ICG) methods.
Methods: HF patients with IVCD 86.8 ± 33 ms (n=15, age 66 ± 10 years; 2 females, 13 males), New York Heart Association (NYHA) functional class 3.1 ± 0.4, left ventricular (LV) ejection fraction 21.3 ± 7.8 % and QRS duration 176.1 ± 31.7 ms underwent AV and VV delay optimization with CO and ACI methods (Cardioscreen, Medis GmbH, Ilmenau, Germany). After evaluation of optimal AV delay, we evaluated optimal VV delay during simultaneous LV and right ventricular (RV) pacing (LV=RV), LV before RV pacing (LV-RV) and RV before LV pacing (RV-LV).
Results: Optimal VV delay was -12.3 ± 25.9 ms LV-RV pacing with VV delay range from -80 ms LV-RV pacing to +20 ms RV-LV pacing and RV=LV pacing. Optimal AV delay after atrial sensing was 108.6 ± 20.3 ms (n=14) and optimal AV delay after atrial pacing 190 ± 14.1 ms (n=2) with AV delay range from 80 ms to 200 ms. RV versus BV pacing mode resulted in improvement of CO from 3.4 ± 1.2 l/min to 4.4 ± 1.4 l/min (p<0.001) and ACI from 0.667 ± 0.227 1/s² to 0.834 ± 0.282 1/s² (p<0.002). During 34 ± 26 month BV pacing, the NYHA class improved from 3.1 ± 0.4 to 2.1 ± 0.4 (p<0.001).
Conclusion: AV and VV delay optimized BV pacing acutely improve ICG CO and ACI and their NYHA class during long-term follow-up. ICG may be a simple and useful technique to optimize AV and VV delay in CRT.
This Master's Thesis discusses intelligent sensor networks considering autonomous sensor placement strategies and system health management. Sensor networks for an intelligent system design process have been researched recently. These networks consist of a distributed collective of sensing units, each with the abilities of individual sensing and computation. Such systems can be capable of self-deployment and must be scalable, long-lived and robust. With distributed sensor networks, intelligent sensor placement for system design and online system health management are attractive areas of research. Distributed sensor networks also cause optimization problems, such as decentralized control, system robustness and maximization of coverage in a distributed system. This also includes the discovery and analysis of points of interest within an environment. The purpose of this study was to investigate a method to control sensor placement in a world with several sources and multiple types of information autonomously. This includes both controlling the movement of sensor units and filtering of the gathered information depending on individual properties to increase system performance, defined as a good coverage. Additionally, online system health management was examined in this study regarding the case of agent failures and autonomous policy reconfiguration if sensors are added to or removed from the system. Two different solution strategies were devised, one where the environment was fully observable, and one with only partial observability. Both strategies use evolutionary algorithms based on artificial neural networks for developing control policies. For performance measurement and policy evaluation, different multiagent objective functions were investigated. The results of the study show that in the case of a world with multiple types of information, individual control strategies performed best because of their abilities to control the movement of a sensor entity and to filter the sensed information. This also includes system robustness in case of sensor failures where other sensing units must recover system performance. Additionally, autonomous policy reconfiguration after adding or removing of sensor agents was successful. This highlights that intelligent sensor agents are able to adapt their individual control policies considering new circumstances.
Active Noise Control (ANC) systems have proved to be a very efficient way to reduce low-frequency acoustic noise. On this domain, passive techniques like enclosures, barriers and silencers tend to be relatively large, costly and ineffective. Although many studies and articles have been published in order to improve performance and stability, the implementation of a real-time, stable and robust system still faces several theoretical and practical challenges.
Radio frequency (RF) power amplifiers (PA) are the most power consuming components of a mobile communications unit. They are used to convert the DC power from the battery into RF power delivered to the antenna. In a cell phone it becomes very important to use highly efficient power amplifiers, such as Class C and Class E PAs, to increase the talk time which is directly proportional to the battery life. On the other hand, these RF PAs are inherently nonlinear and produce spectral regrowth and other undesirable effects.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients with ventricular desynchronisation and reduced left ventricular (LV) function. The aim of this study was to evaluate preejection period (PEP) and left ventricular ejection time (LVET) with transthoracic signal averaging impedance and electrocardiography in HF patients with and without BV pacing.
Methods: 10 HF patients (age 68.9 ± 8 years; 2 females, 9 males) with New York Heart Association (NYHA) class 2,9 ± 0.5, 30.9 ± 10.5 % LV ejection fraction and 159.4 ± 22.9 ms QRS duration were analysed with transthoracic impedance and electrocardiography (Cardioscreen Medis, Ilmenau, Germany) and novel National Intruments LabView 2009 signal averaging software. One day after BV pacing device implantation, AV and VV delays were optimized by transthoracic impedance cardiography and stroke volume (SV) and cardiac output (CO) were gained by Cardioscreen.
Results: Transthoracic impedance and electrocardiography AV and VV delay opimization was possible in all HF patients with BV pacing devices (n= 10). PEP was 154 ± 24ms without BV pacing and measured between onset of QRS in the surface electrocardiogram and onset of ventricular deflection in the impedance cardiogram. LVET was 342 ± 65ms without BV pacing and measured between onset and offset of ventricular deflection in the impedance cardiogram. The use of optimal AV and VV delay BV pacing resulted in improvement of SV from 64.1 ± 26.5 ml to 94.1 ± 33.96 ml (P < 0.05) and CO from 4.05 ± 1.36 l/min to 6.44 ± 1.56 l/min (P < 0.05).
Conclusion: PEP and LVET may be useful parameters of ventricular Desynchronisation. AV and VV delay optimized BV pacing improve SV and CO. Impedance and electrocardiography with LabView 2009 signal averaging may be a simple and useful technique to optimize CRT.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients with sinus rhythm and ventricular desynchronisation. The aim of this study was to evaluate interventricular conduction delay (IVCD) and interatrial conduction delay (IACD) before and after premature ventricular contractions (PVC) in HF patients.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association functional class 2,8 ± 0.5, left ventricular (LV) ejection fraction 28,6 ± 12,6 %, 154 ± 25 ms QRS duration and PVC were analysed with bipolar transesophageal LV and left atrial electrogram recording and National Instruments LabView 2009 software. The level of significance of the t-test is 0,005.
Results: QRS duration increases during PVC (188 ± 32 ms) in comparison to the beat before (154 ± 25 ms, P = ) and after PVC (152 ± 25 ms,). IVCD increases during PVC up to 65 ± 33 ms (51 ± 19 ms in the beat before PVC, P=0.18, 49 ± 19 ms after PVC, P = 0.12). Intra-LV delay of 90 ± 16 ms is not different in the beat before PVC, 90 ± 14 ms during PVC (P = 0.99) and 94 ± 16 ms in the beat after PVC (P = 0.38). IACD is not significantly PVC influenced (67 ± 12 ms before PVC and 65 ± 13 ms after PVC, P = 0.71). Intra-left atrial conduction delay is not significant longer during PVC (57 ± 28 ms) than in the beat before PVC (54 ± 13 ms, P = 0.51) or after PVC (54 ± 8 ms, P = 0.45). PQ duration increases significantly after PVC (224 ± 95 ms) in comparison to the beat before PVC (176± 29 ms, P =...).
Conclusion: Transesophageal left cardiac electrocardiography with LabView 2009 software can improve evaluation of IVCD and IACD before, during and after PVC in HF patient selection for CRT.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation, but not all patients improved clinically. Aim of this study was to evaluate electrical intra-left ventricular conduction delay (LVCD) and interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 65 HF patients (age 63.4 ± 10.6 years; 7 females, 58 males) with New York Heart Association (NYHA) class 3 ± 0.2, 24.4 ± 6.7 % left ventricular (LV) ejection fraction and 167.4 ± 35.6 ms QRSD were included. Esophageal TO Osypka focused hemispherical electrodes catheter was perorally applied in position of maximum LV deflection to measure LVCD between onset and offset of LV deflection and IVCD between earliest onset of QRS in the 12-channel surface ECG and onset of LV deflection in the focused bipolar transesophageal LV electrogram.
Results: There were 50 responders with LVCD of 76.5 ± 20.4 ms, IVCD of 80.5 ± 26.1 ms (P=0.34) and QRSD of 171 ± 37.7 ms. 15 non-responders had longer LVCD of 90 ± 28.5 ms (P = 0.045), shorter IVCD of 50.1 ± 29.1 ms (P < 0.001) and QRSD of 155.3 ± 25 ms (P=0.14). During 21.3 ± 20.3 month BV pacing follow-up, the responder`s NYHA classes improved from 3 ± 0.2 to 2. ± 0.3 (P < 0.001) whereas the non-responders NYHA classes did not improve from 3 ± 0.2 to 2.9 ± 0.3 (P = 0.43) during 15.7 ± 13.9 month BV pacing follow-up (53 Boston, 10 Medtronic and 2 St. Jude CRT devices).
Conclusion: Determination of electrical LVCD and IVCD by focused bipolar transesophageal LV electrogram recording may be an additional useful technique to improve patient selection for CRT.
Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT.
Semi-invasive electromechanical target interval to guide left ventricular electrode placement
(2011)
Introduction: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical ventricular desynchronization with transthoracic and transesophageal signal averaging electrocardiography in HF, to better select patients for CRT.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association (NYHA) class 2.8 ± 0.5, 28.6 ± 12.6 % LV ejection fraction and 155 ± 24 ms QRS duration (QRSD) were analysed with transthoracic and transesophageal electrocardiogram recording and novel National Intruments LabView 2009 signal averaging software. Esophageal TO Osypka catheter was perorally applied to the esophagus and placed in the position of maximum LV de-flection. The 0.05-Hz high-pass filtered surface electrocardiogram and the 10-Hz high-pass filtered bipolar transesophageal electrocardiogram were recorded with Bard EP-System and 1000-Hz sampling rate.
Results: Transesophageal LV electrogram recording was possible in all HF patients (n=13). Transesophageal interventricular conduction delay (IVCD) was 51 ± 19 ms and measured between the earliest onset of QRS in the 12-channel surface electrocardiogram and the onset of the LV deflection in the transesophageal electrocardiogram. Transesophageal intra-left ventricular delay (LVCD) was 90 ± 16 ms and measured between the onset and offset of the LV deflection in the transesophageal electrocardiogram. QRSD to transesophageal IVCD ratio was 3.43 ± 1.31 ms, QRSD to transesophageal LVCD ratio was 1.75 ± 0.28 ms and QRSD was evaluated between onset and offset of QRS signal in the 12-channel surface electrocardiogram.
Conclusion: Determination of IVCD, LVCD, QRSD-to-IVCD-ratio and QRSD-to-LVCD-ratio by transesophageal LV electrogram recording with LabView 2009 signal averaging technique may be useful parameters of ventricular desynchronisation to improve patient selection for CRT.
The idea of this game is to use a flashcard system to create a short story in a foreign language. The story is developed by a group of participants by exchanging sentences via a flashcard system. This way the participants can learn from each other by knowledge sharing without fear of making mistakes because the group members are anonymous. Moreover they do not need a constant support from a teacher.