Refine
Year of publication
- 2018 (41) (remove)
Document Type
- Article (reviewed) (41) (remove)
Is part of the Bibliography
- yes (41) (remove)
Keywords
- Mikrostruktur (2)
- Plastizität (2)
- cardiac resynchronization therapy (2)
- 3D modeling (1)
- 3d Heart Simulation (1)
- Aging (1)
- Alexander von Humboldt (1)
- Astaxanthin (1)
- Canthaxanthin (1)
- Catheter Ablation (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (18)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (12)
- Fakultät Wirtschaft (W) (5)
- INES - Institut für nachhaltige Energiesysteme (5)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- CRT - Campus Research & Transfer (2)
- ACI - Affective and Cognitive Institute (1)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (1)
Open Access
- Closed Access (19)
- Open Access (17)
- Diamond (1)
- Gold (1)
Die Hersteller von Cochlea-Implantat (CI)-Systemen sehen für klinische Audiologen die Möglichkeit vor, die Mikrofonleistung der meisten aktuellen CI-Sprachprozessoren mittels anschließbarer Monitorkopfhörer zu prüfen. Nähere Angaben dazu, nach welchem Prozedere diese Prüfung stattfinden soll, z. B. welche Stimuli mit welchen Pegeln verwendet werden sollen, sind nach Wissen der Autoren seitens der CI-Hersteller nicht verfügbar. Auf der Basis dieser subjektiven Prüfung entscheidet dann der Audiologe, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht. Wir haben eine Messbox entwickelt, mit der die Mikrofonleistung aller abhörbaren CI-Sprachprozessoren der Hersteller Advanced Bionics, Cochlear und MED-EL objektiv geprüft werden kann. Die Box wurde im 3-D-Druckverfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen verbauten Lautsprecher mit definierten Prüfsignalen (Sinustönen unterschiedlicher Frequenz) beschallt. Das Signal des Mikronfons bzw. der Mikrofone wird über das in der Audio-/Abhörbuchse des Prozessors eingesteckte Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die A/D-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten D/AWandler die Ausgabe der Prüfsignale über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgt jeweils mit einer Samplingrate von 38,5 kHz. Der frequenzspezifische Effektivwert des abgegriffenen Mikrofonsignals wird mit einem Referenzwert verglichen. Die (frequenzspezifischen) Referenzwerte wurden mit einem neuwertigen Sprachprozessor gleichen Typs ermittelt und im Speicher des Mikrokontrollers abgelegt. Das Ergebnis wird nach Abschluss der Messung grafisch auf einem Touchscreen ausgegeben. Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. Längerfristiges Ziel ist es, die hit und false alarm Raten der subjektiven Prüfung zu ermitteln.
The authors claim that location information of stationary ICT components can never be unclassified. They describe how swarm-mapping crowd sourcing is used by Apple and Google to worldwide harvest geo-location information on wireless access points and mobile telecommunication systems' base stations to build up gigantic databases with very exclusive access rights. After having highlighted the known technical facts, in the speculative part of this article, the authors argue how this may impact cyber deterrence strategies of states and alliances understanding the cyberspace as another domain of geostrategic relevance. The states and alliances spectrum of activities due to the potential existence of such databases may range from geopolitical negotiations by institutions understanding international affairs as their core business, mitigation approaches at a technical level, over means of cyber deterrence-by-retaliation.
In this article, we present a taxonomy in Robot-Assisted Training; a growing body of research in Human–Robot Interaction which focuses on how robotic agents and devices can be used to enhance user’s performance during a cognitive or physical training task. Robot-Assisted Training systems have been successfully deployed to enhance the effects of a training session in various contexts, i.e., rehabilitation systems, educational environments, vocational settings, etc. The proposed taxonomy suggests a set of categories and parameters that can be used to characterize such systems, considering the current research trends and needs for the design, development and evaluation of Robot-Assisted Training systems. To this end, we review recent works and applications in Robot-Assisted Training systems, as well as related taxonomies in Human–Robot Interaction. The goal is to identify and discuss open challenges, highlighting the different aspects of a Robot-Assisted Training system, considering both robot perception and behavior control.
The production of potable water in dry areas nowadays is mainly done by the desalination of seawater. State of the art desalination plants usually are built with high production capacities and consume a lot of electrical energy or energy from primary resources such as oil. This causes difficulties in rural areas, where no infrastructure is available neither for the plants’ energy supply nor the distribution of the produced potable water. To address this need, small, self-sustaining and locally operated desalination plants came into the focus of research. In this work, a novel flash evaporator design is proposed which can be driven either by solar power or by low temperature waste heat. It offers low operation costs as well as easy maintenance. The results of an experimental setup operated with water at a feed flow rate of up to 1,600 l/h are presented. It is shown that the proof of concept regarding efficient evaporation as well as efficient gas-liquid separation is provided successfully. The experimental evaporation yield counts for 98 % of the vapor content that is expected from the vapor pressure curve of water. Neither measurements of the electrical conductivity of the gained condensate, nor the analysis of the vapor flow by optical methods show significant droplet entrainment, so there are no concerns regarding the purity of the produced condensate for the use as drinking water.
Techno-economic comparison of membrane distillation and MVC in a zero liquid discharge application
(2018)
Membrane distillation (MD) is a thermally driven membrane process for the separation of vapour from a liquid stream through a hydrophobic, microporous membrane. However, a commercial breakthrough on a large scale has not been achieved so far. Specific developments on MD technology are required to adapt the technology for applications in which its properties can potentially outshine state of the art technologies such as standard evaporation. In order to drive these developments in a focused manner, firstly it must be shown that MD can be economically attractive in comparison to state of the art systems. Thus, this work presents a technological design and economic analysis for AGMD and v-AGMD for application in a zero liquid discharge (ZLD) process chain and compares it to the costs of mechanical vapour compression (MVC) for the same application. The results show that MD can potentially be ~40% more cost effective than MVC for a system capacity of 100 m3/day feed water, and up to ~75% more cost effective if the MD is driven with free waste heat.
Membrane distillation (MD) is a thermal separation process which possesses a hydrophobic, microporous
membrane as vapor space. A high potential application for MD is the concentration of hypersaline brines, such as
e.g. reverse osmosis retentate or other saline effluents to be concentrated to a near saturation level with a Zero
Liquid Discharge process chain. In order to further commercialize MD for these target applications, adapted MD
module designs are required along with strategies for the mitigation of membrane wetting phenomena. This
work presents the experimental results of pilot operation with an adapted Air Gap Membrane Distillation
(AGMD) module for hypersaline brine concentration within a range of 0–240 g NaCl /kg solution. Key performance
indicators such as flux, GOR and thermal efficiency are analyzed. A new strategy for wetting mitigation
by active draining of the air gap channel by low pressure air blowing is tested and analyzed. Only small reductions
in flux and GOR of 1.2% and 4.1% respectively, are caused by air sparging into the air gap channel.
Wetting phenomena are significantly reduced by avoiding stagnant distillate in the air gap making the air blower
a seemingly worth- while additional system component.
Cardiac contractility modulation (CCM) is a device-based therapy for the treatment of systolic left ventricular chronic heart failure. Unlike other device-based therapies for heart failure, CCM delivers non-excitatory pacing signals to the myocardium. This leads to an extension of the action potential and to an improved contractility of the heart. The modeling and simulation was done with the electromagnetic simulation software CST. Three CCM electrodes were inserted into the Offenburg heart rhythm model and subsequently simulated the electric field propagation in CCM therapy.
In addition, simulations of CCM have been performed with electrodes from other device-based therapies, such as cardiac resynchronization therapy (CRT) and implantable cardioverter / defibrillator (ICD) therapy. At the same distance to the simulation electrode, the electric field is slightly stronger in CCM therapy than in CCM therapy with additionally implanted CRT or ICD electrodes. In addition, there is a change in the electric field propagation at the electrodes of the CRT and the shock electrode of the ICD.
By simulating several different therapy procedures on the heart, it is possible to check how they affect their behavior during normal operation. CCM heart rhythm model simulation allows the evaluation the individual electrical pacing and sensing field during CCM.
For an elastic medium containing a homogeneous distribution of micro-cracks, an effective one-dimensional stress-strain relation has been determined with finite element simulations. In addition to flat micro-cracks, voids were considered that contain a Hertzian contact, which represents an example for micro-cracks with internal structure. The orientation of both types of micro-cracks was fully aligned or, for flat micro-cracks, totally random. For micro-cracks with Hertzian contacts, the case of random orientation was treated in an approximate way. The two types of defects were found to give rise to different degrees of non-analytic behavior of the effective stress-strain relation, which governs the nonlinear propagation of symmetric (S0) Lamb waves in the long-wavelength limit. The presence of flat micro-cracks causes even harmonics to grow linearly with propagation distance with amplitudes proportional to the amplitude of the fundamental wave, and gives rise to a static strain. The presence of the second type of defects leads to a linear growth of all harmonics with amplitudes proportional to the power 3/2 of the fundamental amplitude, and to a strain-dependent velocity shift. Simple expressions are given for the growth rates of higher harmonics of S0 Lamb waves in terms of the parameters occurring in the effective stress-strain relation. They have partly been determined quantitatively with the help of the FEM results for different micro-crack concentrations.
A printed electronics technology has the advantage of additive and extremely low-cost fabrication compared with the conventional silicon technology. Specifically, printed electrolyte-gated field-effect transistors (EGFETs) are attractive for low-cost applications in the Internet-of-Things domain as they can operate at low supply voltages. In this paper, we propose an empirical dc model for EGFETs, which can describe the behavior of the EGFETs smoothly and accurately over all regimes. The proposed model, built by extending the Enz-Krummenacher-Vittoz model, can also be used to model process variations, which was not possible previously due to fixed parameters for near threshold regime. It offers a single model for all the operating regions of the transistors with only one equation for the drain current. Additionally, it models the transistors with a less number of parameters but higher accuracy compared with existing techniques. Measurement results from several fabricated EGFETs confirm that the proposed model can predict the I-V more accurately compared with the state-of-the-art models in all operating regions. Additionally, the measurements on the frequency of a fabricated ring oscillator are only 4.7% different from the simulation results based on the proposed model using values for the switching capacitances extracted from measurement data, which shows more than 2× improvement compared with the state-of-the-art model.
Pulmonary vein isolation (PVI) is a common therapy in atrial fibrillation (AF). The cryoballoon was invented to isolate the pulmonary vein in one step and in a shorter time than a point-by-point radiofrequency (RF) ablation. The aim of the study was to model two cryoballoon catheters, one RF catheter and to integrate them into a heart rhythm model for the static and dynamic simulation of PVI by cryoablation and RF ablation in AF. The modeling and simulation were carried out using the electromagnetic and thermal simulation software CST (CST, Darmstadt). Two cryoballons and one RF ablation catheter were modeled based on the technical manuals of the manufacturers Medtronic and Osypka. The PVI especially the isolation of the left inferior pulmonary vein using a cryoballoon catheter was performed with a -50 °C heatsource and an exponential signal. The temperature at the balloon surface was -50 °C after 20 s ablation time, -24 °C from the balloon 0,5 mm in the myocardium, at a distance of 1 mm -3 °C, at 2 mm 18 °C and at a distance of 3mm 29 °C. PVI with RF energy was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the tip electrode was 110 °C after 15 s ablation time, 75 °C from the balloon at 0,5 mm in the myocardium, at a distance of 1 mm 58 °C, at 2 mm 45 °C and at a distance of 3 mm 38 °C. Virtual heart rhythm and catheter models as well as the simulation of the temperature allow the simulation of PVI in AF by cryo ablation and RF ablation. The 3D simulation of the temperature profile may be used to optimize RF and cryo ablation.
We present a planar chromatographic separation method for the phytoestrogenic active compound equol, separated on RP-18 W (Merck, 1.14296) phase. It could be shown that an ethanolic cattle manure extract contains this phytoestrogenic active compound to a larger amount. As solvents for the mobile phase, hexane, ethyl acetate, and acetone (45:15:10, v/v); acetone and water (15:10, v/v); and n-hexane, CH2Cl2, ethyl acetate, methanol, and formic acid (40:40:20:5:1, v/v) have been used. After separation, a modified yeast estrogen screen (YES) test was applied, using the yeast strain Saccharomyces cerevisiae BJ3505 containing an estrogen receptor. Its activation by equol induces the reporter gene lacZ which encodes the enzyme β-galactosidase. The enzyme activity is measured directly on the TLC plate by using the substrate MUG (4-methylumbelliferyl-β-d-galactopyranoside) or the substrate X-β-Gal (5-bromo-4-chloro-3-indoxyl-β-d-galactopyranoside). β-Galactosidase cleaves MUG into a fluorescing compound. X-β- Gal is also hydrolyzed and then oxidized by oxygen forming the deep-blue dye 5,5′-dibromo-4,4′-dichloro-indigo. Both reactions in combination with a thin-layer chromatography (TLC) separation allow very specific detecting of equol in cattle manure, although that is a very challenging matrix. Preliminary results show that the average content of equol in liquid manure is roughly 60 μg g−1. The value for urine is 50 μg mL−1.
A Validated Quantification of Sudan Red Dyes in Spicery using TLC and a 16-bit Flatbed Scanner
(2018)
We present a video-densitometric quantification method for Sudan red dyes in spices and spice mixtures, separated by TLC. Application was done band-wise in small dots using a 5 μL glass pipette. For separation, the RP-18 plates (20 × 20 cm with fluorescent dye; Merck, Germany, 1.05559) were developed in a vertical developing chamber without vapor saturation from the starting point to a distance of 70 mm by using acetonitrile, methanol, and aqueous ammonia solution (25%; 8 + 1.8 + 0.2, v/v) as mobile phase. The quantification is based on direct measurements using an inexpensive 16-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of only the green channel makes the measurements very specific. For linearization, an extended Kubelka-Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 20 and 500 ng. The extraction from a 2 g sample with acetonitrile, evaporation, and reconstitution to 200 μL with methanol and the band-wise application (7 mm) of a 10 μL sample allows a statistically defined LOD of less than 500 ppb of Sudan red dyes. To perform the analysis, a separation chamber, RP-18 plates, 5 μL glass pipettes, and a 16-bit flatbed scanner for 105 € are needed; therefore, the separation method is inexpensive, fast, and reliable.
Quantification of astaxanthin in salmons by chemiluminescence and absorption after TLC separation
(2018)
Astaxanthin is a keto-carotenoid, belongs to the chemical class of terpenes and is a yellow lipid soluble compound. The compound is present in marine animals like salmons and crustacean. Its colour is due to conjugated double bonds and these double bonds are responsible for its antioxidant effect. Its antioxidant activity is ten times stronger than other carotenoids and nearly 500 fold stronger than vitamin-E. We present a new thin layer chromatography (TLC) method to measure astaxanthin on TLC-plates (Merck, 1.05554) in the visible absorption range as well as by using chemiluminescence. For separation a solvent mixture of cyclohexane and acetone (10 + 2.4, v/v) was used. The RF-value of astaxanthin is 0.14.The limit of detection in vis-absorption is 64 ng / band and the limit of quantification is 92 ng/band. In chemiluminescence the values are 90 ng / band and 115 ng/band. The method offers two independently working measurement modes on a single plate which increase the accuracy of the quantification.
In this paper the yield surface of a recently presented microstructure-based volume element of the gray cast iron material GJL-250 is assessed after different plastic loading histories. The evolution of the yield surface is investigated for different volumetric, deviatoric and uniaxial loadings. The micromechanical material properties of the metallic matrix and the graphite inclusions are validated by means experimental stress-strain hysteresis loops. The metallic matrix is modeled as elastic-plastic with a non-linear kinematic hardening law. The graphite inclusions are described by means of a volumetric strain state dependent Young’s modulus. The results show that the shape of the yield surface does not change significantly in comparison to the initial yield surface after pure deviatoric loadings. After volumetric loadings, the dependence of the material on the Lode angle is significantly reduced. Uniaxial tensile preloadings result in a deformed yield surface, whereby the magnitude of the deformation depends on the applied load. Uniaxial preloadings to compression do not change the shape of the initial yield surface.