Refine
Year of publication
Document Type
- Article (reviewed) (139) (remove)
Is part of the Bibliography
- yes (139) (remove)
Keywords
- Intelligentes Stromnetz (5)
- Lithiumbatterie (5)
- Batterie (3)
- Brennstoffzelle (3)
- Elektrolyt (3)
- Netzwerk (3)
- Automatisierungssystem (2)
- CDMA (2)
- Codierung (2)
- Computer Aided Design (CAD) (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (139) (remove)
Open Access
- Closed Access (58)
- Open Access (34)
- Closed (3)
- Gold (2)
In this paper we integrate the ideas of network coding and relays into an existing practical network architecture used in a wireless network scenario. Specifically, we use the COPE architecture to test our ideas. Since previous works have focused on the communication aspect at the physical layer level, we attempt to take it one step further by including the MAC layer. Our idea is based on information theoretic concepts developed by Shannon in order to reliably apply network coding to increase the net throughput.
In the past two decades much has been published on whiplash injury, yet both the confusion regarding the condition, and the medicolegal discussion about it have increased. In this paper, functional imaging research results are summarized using MRIcroGL3D visualization software and assembled in an image comprising regions of cerebral activation and deactivation.
Um Simulationen schnell und kostengünstig sowie ergebnisträchtig durchzuführen, bedarf es einer sorgfältigen Vorbereitung. Der Artikel befaßt sich mit dem automatischen Ablauf einer Simulationstudie zum Materilafluß und erläutert die im Ablauf notwendigen Beiträge der Anwender. In den Einzelheiten wird über die automatische Vorgehensweise und Anwendung der Standard-Simulationsmodelle (SSM) sowie spezieller Simulationsmodule (SimDBC) berichtet. Entscheidend für eine breitere Anwendung von Simulationswerkzeugen ist die einfache Handhabung und leicht verständliche Definition der zu untersuchenden Szenarien.
Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT.
BACKGROUND:
While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL.
METHODS:
This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada.
RESULTS:
A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable.
CONCLUSION:
A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
The suffix-free-prefix-free hash function construction and its indifferentiability security analysis
(2012)
In this paper, we observe that in the seminal work on indifferentiability analysis of iterated hash functions by Coron et al. and in subsequent works, the initial value (IV) of hash functions is fixed. In addition, these indifferentiability results do not depend on the Merkle–Damgård (MD) strengthening in the padding functionality of the hash functions. We propose a generic n-bit-iterated hash function framework based on an n-bit compression function called suffix-free-prefix-free (SFPF) that works for arbitrary IVs and does not possess MD strengthening. We formally prove that SFPF is indifferentiable from a random oracle (RO) when the compression function is viewed as a fixed input-length random oracle (FIL-RO). We show that some hash function constructions proposed in the literature fit in the SFPF framework while others that do not fit in this framework are not indifferentiable from a RO. We also show that the SFPF hash function framework with the provision of MD strengthening generalizes any n-bit-iterated hash function based on an n-bit compression function and with an n-bit chaining value that is proven indifferentiable from a RO.
Routine nuclear cardiology examinations indicate heart rate, cardiac rhythm, the height of cardiac pulse and respiration rhythm. It would be of interest to study whether these data, especially if the same tests are repeated, can indicate patients’ well being in the future and perhaps patients’ life span, other factors being equal. Related old theories and suggestions are mentioned. Furthermore, some drugs like I-f channel antagonists and stress tests testing cardiac reserves could support such a study.
Chronic insomnia is defined by difficulties in falling asleep, maintaining sleep, and early morning awakening, and is coupled with daytime consequences such as fatigue, attention deficits, and mood instability. These symptoms persist over a period of at least 3 months (Diagnostic and Statistical Manual 5 criteria). Chronic insomnia can be a symptom of many medical, neurological, and mental disorders. As a disorder, it incurs substantial health-care and occupational costs, and poses substantial risks for the development of cardiovascular and mental disorders, including cognitive deficits. Family and twin studies confirm that chronic insomnia can have a genetic component (heritability coefficients between 42% and 57%), whereas the investigation of autonomous and central nervous system parameters has identified hyperarousal as a final common pathway of the pathophysiology, implicating an imbalance of sleep–wake regulation consisting of either overactivity of the arousal systems, hypoactivity of the sleep-inducing systems, or both. Insomnia treatments include benzodiazepines, benzodiazepine-receptor agonists, and cognitive behavioural therapy. Treatments currently under investigation include transcranial magnetic or electrical brain stimulation, and novel methods to deliver psychological interventions.
The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users
(2016)
Objective: The present study evaluated whether the poorer baseline performance of cochlear implant (CI) users or the technical and/or physiological properties of CI stimulation are responsible for the absence of masking release. Design: This study measured speech reception thresholds (SRTs) in continuous and modulated noise as a function of signal to noise ratio (SNR). Study sample: A total of 24 subjects participated: 12 normal-hearing (NH) listeners and 12 subjects provided with recent MED-EL CI systems. Results: The mean SRT of CI users in continuous noise was −3.0 ± 1.5 dB SNR (mean ± SEM), while the normal-hearing group reached −5.9 ± 0.8 dB SNR. In modulated noise, the difference across groups increased considerably. For CI users, the mean SRT worsened to −1.4 ± 2.3 dB SNR, while it improved for normal-hearing listeners to −18.9 ± 3.8 dB SNR. Conclusions: The detrimental effect of fluctuating maskers on SRTs in CI users shown by prior studies was confirmed by the current study. Concluding, the absence of masking release is mainly caused by the technical and/or physiological properties of CI stimulation, not just the poorer baseline performance of many CI users compared to normal-hearing subjects. Speech understanding in modulated noise was more robust in CI users who had a relatively large electrical dynamic range.
A laser-operated, angle-tunable transducer was employed to excite selectively elastic waves guided along the apex of a solid wedge. The propagation of wedge waves at anisotropic monocrystalline silicon edges with different symmetry properties was studied by optical detection. The reduced symmetry in crystals, as compared to isotropic media, causes a number of new features, such as the existence of supersonic leaky wedge waves, tilted spatial pulse profiles, and other peculiarities of their localization. Experimental and theoretical results are presented for three different types of symmetry configurations: the wedge symmetric about its midplane, the wedge symmetric about the plane normal to its apex line, and the wedge symmetric about one of its faces. The experiments include accurate measurements of the phase velocity and the wave field distribution, providing information on localization and coupling of wedge waves with other waves. Theoretically, the wedge waves were treated by the Laguerre function method, extended to modes that are not localized at the tip of the wedge. This approach allowed an accurate description of the observed localized and leaky wedge waves in anisotropic wedges.
Structured Innovation with TRIZ in Science and Industry - Creating Value for Customers and Society
(2016)
Streustrahlung in der Ultraschall-Computertomographie zur Verifizierung der Echtheit von Perlen
(2017)
This paper describes a new analysis method developed to distinguish real from fake
pearls using non-ionizing, non-destructive ultrasound computed tomography (USCT): In the USCT Shepp-Logan-filtered time-of-flight image, a fake pearl shows irregular, asymmetric
scattering of ultrasound, whereas the pattern in a natural pearl is regular and symmetric.
We strongly assume that pattern recognition of the scattering of ultrasound cannot only
play an important role in verifying pearls, but also in testing other materials and tissues in
(bio-)medical engineering. Furthermore, and most importantly, this new approach could
be helpful for a variety of clinical diagnoses using high-resolution 3D-USCT, such as the
detection of X-ray-negative micro-calcifications in early breast cancer. Moreover looking
at scattering patterns in dedicated positron emission tomography systems may promote
new developments in nuclear medicine diagnostics.
Since their dawning, space communications have been among the strongest driving applications for the development of error correcting codes. Indeed, space-to-Earth telemetry (TM) links have extensively exploited advanced coding schemes, from convolutional codes to Reed-Solomon codes (also in concatenated form) and, more recently, from turbo codes to low-density parity-check (LDPC) codes. The efficiency of these schemes has been extensively proved in several papers and reports. The situation is a bit different for Earth-to-space telecommand (TC) links. Space TCs must reliably convey control information as well as software patches from Earth control centers to scientific payload instruments and engineering equipment onboard (O/B) spacecraft. The success of a mission may be compromised because of an error corrupting a TC message: a detected error causing no execution or, even worse, an undetected error causing a wrong execution. This imposes strict constraints on the maximum acceptable detected and undetected error rates.