Refine
Year of publication
Document Type
- Article (reviewed) (285) (remove)
Is part of the Bibliography
- yes (285) (remove)
Keywords
- Dünnschichtchromatographie (17)
- Adsorption (10)
- Metallorganisches Netzwerk (9)
- Ermüdung (8)
- Plastizität (8)
- Simulation (6)
- 3D printing (5)
- Energieversorgung (5)
- HPTLC (5)
- Mikrostruktur (5)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (285) (remove)
Open Access
- Open Access (114)
- Closed Access (104)
- Closed (30)
- Gold (29)
- Hybrid (14)
- Diamond (10)
Background
To assess the in-field walking mechanics during downhill hiking of patients with total knee arthroplasty five to 14 months after surgery and an age-matched healthy control group and relate them to the knee flexor and extensor muscle strength.
Methods
Participants walked on a predetermined hiking trail at a self-selected, comfortable pace wearing an inertial sensor system for recording the whole-body 3D kinematics. Sagittal plane hip, knee, and ankle joint angles were evaluated over the gait cycle at level walking and two different negative slopes. The concentric and eccentric lower extremity muscle strength of the knee flexors and extensors isokinetically at 50 and 120°/s were measured.
Findings
Less knee flexion angles during stance have been measured in patients in the operated limb compared to healthy controls in all conditions (level walking, moderate downhill, steep downhill). The differences increased with steepness. Muscle strength was lower in patients for both muscle groups and all measured conditions. The functional hamstrings to quadriceps ratio at 120°/sec correlated with knee angle during level and downhill walking at the moderate slope in patients, showing higher ratios with lower peak knee flexion angles.
Interpretation
The study shows that even if rehabilitation has been completed successfully and complication-free, five to 14 months after surgery, the muscular condition was still insufficient to display a normal gait pattern during downhill hiking. The muscle balance between quadriceps and hamstring muscles seems related to the persistence of a stiff knee gait pattern after knee arthroplasty. LoE: III.
A novel peptidyl-lys metalloendopeptidase (Tc-LysN) from Tramates coccinea was recombinantly expressed in Komagataella phaffii using the native pro-protein sequence. The peptidase was secreted into the culture broth as zymogen (~38 kDa) and mature enzyme (~19.8 kDa) simultaneously. The mature Tc-LysN was purified to homogeneity with a single step anion-exchange chromatography at pH 7.2. N-terminal sequencing using TMTpro Zero and mass spectrometry of the mature Tc-LysN indicated that the pro-peptide was cleaved between the amino acid positions 184 and 185 at the Kex2 cleavage site present in the native pro-protein sequence. The pH optimum of Tc-LysN was determined to be 5.0 while it maintained ≥60% activity between pH values 4.5—7.5 and ≥30% activity between pH values 8.5—10.0, indicating its broad applicability. The temperature maximum of Tc-LysN was determined to be 60 °C. After 18 h of incubation at 80 °C, Tc-LysN still retained ~20% activity. Organic solvents such as methanol and acetonitrile, at concentrations as high as 40% (v/v), were found to enhance Tc-LysN’s activity up to ~100% and ~50%, respectively. Tc-LysN’s thermostability, ability to withstand up to 8 M urea, tolerance to high concentrations of organic solvents, and an acidic pH optimum make it a viable candidate to be employed in proteomics workflows in which alkaline conditions might pose a challenge. The nano-LC-MS/MS analysis revealed bovine serum albumin (BSA)’s sequence coverage of 84% using Tc-LysN which was comparable to the sequence coverage of 90% by trypsin peptides.
Hintergrund
In diesem Artikel wird ein Überblick und Vergleich der am häufigsten verwendeten zementierten Hüftschäfte, gruppiert in die verschiedenen Schafttypen und Zementmanteldicken, gegeben, um zu sehen, welche Kombination gut abschneidet.
Methodik
Aus dem Endoprothesenregister Deutschland wurden die Revisionsraten zementierter Schaftarten kategorisiert und die Revisionsraten von 3 und 5 Jahren erfasst und analysiert. Für die Recherche lag die Konzentration auf den Schäften Exeter, C‑Stem, MS-30, Excia, Bicontact, Charnley, Müller Geradschaft, Twinsys, Corail, Avenir, Quadra und dem Lubinus SP II. Ein wichtiger Aspekt lag darin, welcher Schaft favorisiert implantiert wird und welche Zementiertechnik in Hinblick auf die geplante Zementmanteldicke angewendet wird. Um einen Trend in der zementierten Hüftendoprothetik herauszufinden, wurden zusätzlich die Daten des dänischen, schwedischen, norwegischen, schweizerischen, neuseeländischen, englischen und australischen Endoprothesenregister verglichen.
Ergebnisse und Schlussfolgerung
Die meisten Länder nutzen zementierte Prothesen nach dem Kraftschlussprinzip (Exeter, MS30, C‑Stem etc.) oder dem Formschlussprinzip (Charnley, Excia, Bicontact), welche mit einer Zementmanteldicke von 2–4 mm implantiert werden. Jedoch hat sich in Deutschland und der Schweiz ein Trend zur Line-to-Line-Technik, mit einer geplanten Zementmanteldicke von 1 mm (Twinsys, Corail, Avenir, Quadra) aufgezeigt, dem Prinzip der Müller-Geradschaft-Prothese und der Kerboul-Charnley-Prothese folgend, auch wenn diese an sich als „french paradoxon“ postuliert werden. In den EPRD-5-Jahres-Ergebnissen scheinen die neueren Line-to-Line-Prothesen etwas schlechter abzuschneiden. Die besten Ergebnisse erzielt der „MS 30“ in Deutschland und der „Exeter“ in England. Hierbei handelt es sich um polierte Geradschäfte mit Zentraliser und Subsidence-Raum an der Spitze mit einem 2–4 mm Zementmantel in guter Zementiertechnik.
Photovoltaic-heat pump (PV-HP) combinations with battery and energy management systems are becoming increasingly popular due to their ability to increase the autarchy and utilization of self-generated PV electricity. This trend is driven by the ongoing electrification of the heating sector and the growing disparity between growing electricity costs and reducing feed-in tariffs in Germany. Smart control strategies can be employed to control and optimize the heat pump operation to achieve higher self-consumption of PV electricity. This work presents the evaluation results of a smart-grid ready controlled PV-HP-battery system in a single-family household in Germany, using 1-minute-high-resolution field measurement data. Within 12 months evaluation period, a self-consumption of 43% was determined. The solar fraction of the HP amounts to 36%, enabled also due to higher set temperatures for space heating and domestic hot water production. Accordingly, the SPF decreases by 4.0% the space heating and by 5.7% in the domestic hot water mode. The combined seasonal performance factor for the heat pump system increases from 4.2 to 6.7, when only considering the electricity taken from the grid and disregarding the locally generated electricity supplied from photovoltaic and battery units.
In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = −1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = −0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
Injury prevention is essential in running due to the risk of overuse injury development. Tailoring running shoes to individual needs may be a promising strategy to reduce this risk. Novel manufacturing processes allow the production of individualised running shoes that incorporate features that meet individual biomechanical and experiential needs. However, specific ways to individualise footwear to reduce injury risk are poorly understood. Therefore, this scoping review provides an overview of (1) footwear design features that have the potential for individualisation; and (2) the literature on the differential responses to footwear design features between selected groups of individuals. These purposes focus exclusively on reducing the risk of overuse injuries. We included studies in the English language on adults that analysed: (1) potential interaction effects between footwear design features and subgroups of runners or covariates (e.g., age, sex) for running-related biomechanical risk factors or injury incidences; (2) footwear comfort perception for a systematically modified footwear design feature. Most of the included articles (n = 107) analysed male runners. Female runners may be more susceptible to footwear-induced changes and overuse injury development; future research should target more heterogonous sampling. Several footwear design features (e.g., midsole characteristics, upper, outsole profile) show potential for individualisation. However, the literature addressing individualised footwear solutions and the potential to reduce biomechanical risk factors is limited. Future studies should leverage more extensive data collections considering relevant covariates and subgroups while systematically modifying isolated footwear design features to inform footwear individualisation.
For the treatment of bone defects, biodegradable, compressive biomaterials are needed as replacements that degrade as the bone regenerates. The problem with existing materials has either been their insufficient mechanical strength or the excessive differences in their elastic modulus, leading to stress shielding and eventual failure. In this study, the compressive strength of CPC ceramics (with a layer thickness of more than 12 layers) was compared with sintered β-TCP ceramics. It was assumed that as the number of layers increased, the mechanical strength of 3D-printed scaffolds would increase toward the value of sintered ceramics. In addition, the influence of the needle inner diameter on the mechanical strength was investigated. Circular scaffolds with 20, 25, 30, and 45 layers were 3D printed using a 3D bioplotter, solidified in a water-saturated atmosphere for 3 days, and then tested for compressive strength together with a β-TCP sintered ceramic using a Zwick universal testing machine. The 3D-printed scaffolds had a compressive strength of 41.56 ± 7.12 MPa, which was significantly higher than that of the sintered ceramic (24.16 ± 4.44 MPa). The 3D-printed scaffolds with round geometry reached or exceeded the upper limit of the compressive strength of cancellous bone toward substantia compacta. In addition, CPC scaffolds exhibited more bone-like compressibility than the comparable β-TCP sintered ceramic, demonstrating that the mechanical properties of CPC scaffolds are more similar to bone than sintered β-TCP ceramics.
Recently, photovoltaic (PV) with energy storage systems (ESS) have been widely adopted in buildings to overcome growing power demands and earn financial benefits. The overall energy cost can be optimized by combining a well-sized hybrid PV/ESS system with an efficient energy management system (EMS). Generally, EMS is implemented within the overall functions of the Building Automation System (BAS). However, due to its limited computing resources, BAS cannot handle complex algorithms that aim to optimize energy use in real-time under different operating conditions. Furthermore, islanding the building's local network to maximize the PV energy share represents a challenging task due to the potential technical risks. In this context, this article addresses an improved approach based on upgrading the BAS data analytics capability by means of an edge computing technology. The edge communicates with the BAS low-level controller using a serial communication protocol. Taking advantage of the high computing ability of the edge device, an optimization-based EMS of the PV/ESS hybrid system is implemented. Different testing scenarios have been carried out on a real prototype with different weather conditions, and the results show the implementation feasibility and technical performance of such advanced EMS for the management of building energy resources. It has also been proven to be feasible and advantageous to operate the local energy network in island mode while ensuring system safety. Additionally, an estimated energy saving improvement of 6.23 % has been achieved using optimization-based EMS compared to the classical rule-based EMS, with better ESS constraints fulfillment.
In this paper, the J-integral is derived for temperature-dependent elastic–plastic materials described by incremental plasticity. It is implemented using the equivalent domain integral method for assessment of three-dimensional cracks based on results of finite-element calculations. The J-integral considers contributions from inhomogeneous temperature fields and temperature-dependent elastic and plastic material properties as well as from gradients in the plastic strains and the hardening variables. Different energy densities are considered, the Helmholtz free energy and the stress-working density, providing a physical meaning of the J-integral as a fracture criteria for crack growth. Results obtained for a plate with two different crack configurations each loaded by a cool-down thermal shock show domain-independence of the incremental J-integral for different energy densities even for high temperature gradients and significant temperature-dependence of the yield stress and the hardening exponent in the presence of large scale yielding. Hence, the derived J-integral is an appropriate parameter for the assessment of cracks in thermomechanically loaded components.
Enzyme‐assisted HPTLC method for the simultaneous analysis of inositol phosphates and phosphate
(2023)
Background
The analysis of myo‐inositol phosphates (InsPx) released by phytases during phytic acid degradation is challenging and time‐consuming, particularly in terms of sample preparation, isomer separation, and detection. However, a fast and robust analysis method is crucial when screening for phytases during protein engineering approaches, which result in a large number of samples, to ensure reliable identification of promising novel enzymes or target variants with improved characteristics, for example, pH range, thermal stability, and phosphate release kinetics.
Results
The simultaneous analysis of several InsPx (InsP1‐InsP4 and InsP5 + 6) as well as free phosphate was established on cellulose HPTLC plates using a buffered mobile phase. Inositol phosphates were subsequently stained using a novel enzyme‐assisted staining procedure. Immobilized InsPx were hydrolyzed by a phytase solution of Quantum® Blueliquid 5G followed by a molybdate reagent derivatization. Resulting blue zones were captured by DAD scan. The method shows good repeatability (intra‐day and intra‐lab) with maximum deviations of the Rf value of 0.01. The HPTLC method was applied to three commercially available phytases at two pH levels relevant to the gastrointestinal tract of poultry (pH 5.5 and pH 3.6) to observe their phytate degradation pattern and thus visualize their InsPx fingerprint.
Conclusion
This HPTLC method presents a semi‐high‐throughput analysis for the simultaneous analysis of phytic acid and the resulting lower inositol phosphates after its enzymatic hydrolysis and is also an effective tool to visualize the InsPx fingerprints and possible accumulations of inositol phosphates.
Building energy management systems (BEMSs), dedicated to sustainable buildings, may have additional duties, such as hosting efficient energy management systems (EMSs) algorithms. This duty can become crucial when operating renewable energy sources (RES) and eventual electric energy storage systems (ESSs). Sophisticated EMS approaches that aim to manage RES and ESSs in real time may need high computing capabilities that BEMSs typically cannot provide. This article addresses and validates a fuzzy logic-based EMS for the optimal management of photovoltaic (PV) systems with lead-acid ESSs using an edge computing technology. The proposed method is tested on a real smart grid prototype in comparison with a classical rule-based EMS for different weather conditions. The goal is to investigate the efficacy of islanding the building local network as a control command, along with ESS power control. The results show the implementation feasibility and performance of the fuzzy algorithm in the optimal management of ESSs in both operation modes: grid-connected and islanded modes.
Purpose
To summarize the mechanical loading of the spine in different activities of daily living and sports.
Methods
Since the direct measurement is not feasible in sports activities, a mathematical model was applied to quantify spinal loading of more than 600 physical tasks in more than 200 athletes from several sports disciplines. The outcome is compression and torque (normalized to body weight/mass) at L4/L5.
Results
The data demonstrate high compressive forces on the lumbar spine in sport-related activities, which are much higher than forces reported in normal daily activities and work tasks. Especially ballistic jumping and landing skills yield high estimated compression at L4/L5 of more than ten times body weight. Jumping, landing, heavy lifting and weight training in sports demonstrate compression forces significantly higher than guideline recommendations for working tasks.
Conclusion
These results may help to identify acute and long-term risks of low back pain and, thus, may guide the development of preventive interventions for low back pain or injury in athletes.
Appraising the Methodological Quality of Sports Injury Video Analysis Studies: The QA-SIVAS Scale
(2023)
Background
Video analysis (VA) is commonly used in the assessment of sports injuries and has received considerable research interest. Until now, no tool has been available for the assessment of study quality. Therefore, the objective of this study was to develop and evaluate a valid instrument that reliably assesses the methodological quality of VA studies.
Methods
The Quality Appraisal for Sports Injury Video Analysis Studies (QA-SIVAS) scale was developed using a modified Delphi approach including expert consensus and pilot testing. Reliability was examined through intraclass correlation coefficient (ICC3,1) and free-marginal kappa statistics by three independent raters. Construct validity was investigated by comparing QA-SIVAS with expert ratings by using Kendall’s tau analysis. Rating time was studied by applying the scale to 21 studies and computing the mean time for rating per study article.
Results
The QA-SIVAS scale consists of an 18-item checklist addressing the study design, data source, conduct, report, and discussion of VA studies in sports injury research. Inter- and intra-rater reliability were excellent with ICCs > 0.97. Expert ratings revealed a high construct validity (0.71; p < 0.001). Mean rating time was 10 ± 2 min per article.
Conclusion
QA-SIVAS is a reliable and valid instrument that can be easily applied to sports injury research. Future studies in the field of VA should adhere to standardized methodological criteria and strict quality guidelines.
Background
Internal tibial loading is influenced by modifiable factors with implications for the risk of stress injury. Runners encounter varied surface steepness (gradients) when running outdoors and may adapt their speed according to the gradient. This study aimed to quantify tibial bending moments and stress at the anterior and posterior peripheries when running at different speeds on surfaces of different gradients.
Methods
Twenty recreational runners ran on a treadmill at 3 different speeds (2.5 m/s, 3.0 m/s, and 3.5 m/s) and gradients (level: 0%; uphill: +5%, +10%, and +15%; downhill: –5%, –10%, and –15%). Force and marker data were collected synchronously throughout. Bending moments were estimated at the distal third centroid of the tibia about the medial–lateral axis by ensuring static equilibrium at each 1% of stance. Stress was derived from bending moments at the anterior and posterior peripheries by modeling the tibia as a hollow ellipse. Two-way repeated-measures analysis of variance were conducted using both functional and discrete statistical analyses.
Results
There were significant main effects for running speed and gradient on peak bending moments and peak anterior and posterior stress. Higher running speeds resulted in greater tibial loading. Running uphill at +10% and +15% resulted in greater tibial loading than level running. Running downhill at –10% and –15% resulted in reduced tibial loading compared to level running. There was no difference between +5% or –5% and level running.
Conclusion
Running at faster speeds and uphill on gradients ≥+10% increased internal tibial loading, whereas slower running and downhill running on gradients ≥–10% reduced internal loading. Adapting running speed according to the gradient could be a protective mechanism, providing runners with a strategy to minimize the risk of tibial stress injuries.
Footwear plays a critical role in our daily lives, affecting our performance, health and overall well-being. Well-designed footwear can provide protection, comfort and improved foot functionality, while poorly designed footwear can lead to mobility problems and declines in physical activity. The overall goal of footwear research is to provide a scientific basis for professionals in the field to provide an optimal footwear solution for a given person, for a given task, in a given environment, while using sustainable manufacturing processes. This article suggests potential directions for future research with a focus on athletic footwear biomechanics. Directions include the evidence-based individualisation of footwear, the interaction between design and prolonged use, and improving the sustainability of footwear. The authors also provide a speculative outlook on methodological developments that may provide greater insight into these areas. These developments may include: (1) the use of larger scale, real-world and representative data, (2) the use of 3D printing to create experimental footwear, (3) the advancement of in silico research methods, and (4) furthering multidisciplinary collaboration. If successfully applied in the future, footwear research will contribute to active and healthy lifestyles across the lifespan.
Purpose
To (1) identify neuromuscular and biomechanical injury risk factors in elite youth soccer players and (2) assess the predictive ability of a machine learning approach.
Material and Methods
Fifty-six elite male youth soccer players (age: 17.2 ± 1.1 years; height: 179 ± 8 cm; mass: 70.4 ± 9.2 kg) performed a 3D motion analysis, postural control testing, and strength testing. Non-contact lower extremities injuries were documented throughout 10 months. A least absolute shrinkage and selection operator (LASSO) regression model was used to identify the most important injury predictors. Predictive performance of the LASSO model was determined in a leave-one-out (LOO) prediction competition.
Results
Twenty-three non-contact injuries were registered. The LASSO model identified concentric knee extensor peak torque, hip transversal plane moment in the single-leg drop landing task and center of pressure sway in the single-leg stance test as the three most important predictors for injury in that order. The LASSO model was able to predict injury outcomes with a likelihood of 58% and an area under the ROC curve of 0.63 (sensitivity = 35%; specificity = 79%).
Conclusion
The three most important variables for predicting the injury outcome suggest the importance of neuromuscular and biomechanical performance measures in elite youth soccer. These preliminary results may have practical implications for future directions in injury risk screening and planning, as well as for the development of customized training programs to counteract intrinsic injury risk factors. However, the poor predictive performance of the final model confirms the challenge of predicting sports injuries, and the model must therefore be evaluated in larger samples.
Bewegungsanalysesysteme in der Forschung und für niedergelassene Orthopädinnen und Orthopäden
(2023)
Hintergrund
Komplexe biomechanische Bewegungsanalysen können für eine Vielzahl orthopädischer Fragestellungen wichtige Informationen liefern. Bei der Beschaffung von Bewegungsanalysesystemen sind neben den klassischen Messgütekriterien (Validität, Reliabilität, Objektivität) auch räumliche und zeitliche Rahmenbedingungen sowie Anforderungen an die Qualifikation des Messpersonals zu berücksichtigen.
Anwendung
In der komplexen Bewegungsanalyse werden Systeme zur Bestimmung der Kinematik, der Kinetik und der Muskelaktivität (Elektromyographie) eingesetzt. Der vorliegende Artikel gibt einen Überblick über Methoden der komplexen biomechanischen Bewegungsanalyse für den Einsatz in der orthopädischen Forschung oder in der individuellen Patientenversorgung. Neben dem Einsatz zur reinen Bewegungsanalyse wird auch der Einsatz von Bewegungsanalyseverfahren im Bereich des Biofeedbacktrainings diskutiert.
Beschaffung
Für die konkrete Anschaffung von Bewegungsanalysesystemen empfiehlt sich die Kontaktaufnahme mit Fachgesellschaften (z. B. Deutsche Gesellschaft für Biomechanik), Hochschulen und Universitäten mit vorhandenen Bewegungsanalyseeinrichtungen oder Vertriebsfirmen im Bereich der Biomechanik.
Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes.
Maintaining stability while walking on arbitrary surfaces or dealing with external perturbations is of great interest in humanoid robotics research. Increasing the system’s autonomous robustness to a variety of postural threats during locomotion is the key despite the need to evaluate noisy sensor signals. The equations of motion are the foundation of all published approaches. In contrast, we propose a more adequate evaluation of the equations of motion with respect to an arbitrary moving reference point in a non-inertial reference frame. Conceptual advantages are, e.g., getting independent of global position and velocity vectors estimated by sensor fusions or calculating the imaginary zero-moment point walking on different inclined ground surfaces. Further, we improve the calculation results by reducing noise-amplifying methods in our algorithm and using specific characteristics of physical robots. We use simulation results to compare our algorithm with established approaches and test it with experimental robot data.