Refine
Year of publication
Document Type
- Article (reviewed) (71)
- Contribution to a Periodical (53)
- Conference Proceeding (26)
- Report (6)
- Part of a Book (1)
- Patent (1)
- Article (unreviewed) (1)
- Working Paper (1)
Conference Type
- Konferenzartikel (25)
- Konferenz-Poster (1)
- Sonstiges (1)
Has Fulltext
- yes (160) (remove)
Is part of the Bibliography
- yes (160) (remove)
Keywords
- 3D printing (5)
- Chromatography (5)
- Laboratory Medicine (5)
- Monitoring/Environmental Analysis (5)
- Pharmacy (5)
- lithium-ion battery (5)
- Biologische Methanisierung (4)
- COVID-19 (3)
- Gebäudeklimatisierung (3)
- biomechanics (3)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (160) (remove)
Open Access
- Open Access (157)
- Hybrid (29)
- Gold (28)
- Bronze (16)
- Diamond (12)
- Grün (5)
- Closed (2)
- Closed Access (1)
In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = −1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = −0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
Recently, photovoltaic (PV) with energy storage systems (ESS) have been widely adopted in buildings to overcome growing power demands and earn financial benefits. The overall energy cost can be optimized by combining a well-sized hybrid PV/ESS system with an efficient energy management system (EMS). Generally, EMS is implemented within the overall functions of the Building Automation System (BAS). However, due to its limited computing resources, BAS cannot handle complex algorithms that aim to optimize energy use in real-time under different operating conditions. Furthermore, islanding the building's local network to maximize the PV energy share represents a challenging task due to the potential technical risks. In this context, this article addresses an improved approach based on upgrading the BAS data analytics capability by means of an edge computing technology. The edge communicates with the BAS low-level controller using a serial communication protocol. Taking advantage of the high computing ability of the edge device, an optimization-based EMS of the PV/ESS hybrid system is implemented. Different testing scenarios have been carried out on a real prototype with different weather conditions, and the results show the implementation feasibility and technical performance of such advanced EMS for the management of building energy resources. It has also been proven to be feasible and advantageous to operate the local energy network in island mode while ensuring system safety. Additionally, an estimated energy saving improvement of 6.23 % has been achieved using optimization-based EMS compared to the classical rule-based EMS, with better ESS constraints fulfillment.
For the treatment of bone defects, biodegradable, compressive biomaterials are needed as replacements that degrade as the bone regenerates. The problem with existing materials has either been their insufficient mechanical strength or the excessive differences in their elastic modulus, leading to stress shielding and eventual failure. In this study, the compressive strength of CPC ceramics (with a layer thickness of more than 12 layers) was compared with sintered β-TCP ceramics. It was assumed that as the number of layers increased, the mechanical strength of 3D-printed scaffolds would increase toward the value of sintered ceramics. In addition, the influence of the needle inner diameter on the mechanical strength was investigated. Circular scaffolds with 20, 25, 30, and 45 layers were 3D printed using a 3D bioplotter, solidified in a water-saturated atmosphere for 3 days, and then tested for compressive strength together with a β-TCP sintered ceramic using a Zwick universal testing machine. The 3D-printed scaffolds had a compressive strength of 41.56 ± 7.12 MPa, which was significantly higher than that of the sintered ceramic (24.16 ± 4.44 MPa). The 3D-printed scaffolds with round geometry reached or exceeded the upper limit of the compressive strength of cancellous bone toward substantia compacta. In addition, CPC scaffolds exhibited more bone-like compressibility than the comparable β-TCP sintered ceramic, demonstrating that the mechanical properties of CPC scaffolds are more similar to bone than sintered β-TCP ceramics.
Background/Purpose
Several methods are used to evaluate the outcome of total hip arthroplasty (THA), however, their relationship at different time points after surgery is unclear. The purpose of this exploratory study was to investigate correlations between self-report function, performance-based tests (PBTs) and biomechanical parameters in patients 12 months after THA.
Methods
Eleven patients were included in this preliminary cross-sectional study. Hip disability and Osteoarthritis Outcome Score (HOOS) was completed for self-reported function. As PBTs, the Timed-up-and-Go test (TUG) and 30-Second-Chair-Stand test (30CST) were used. Biomechanical parameters were derived from analyses of hip strength, gait and balance. Potential correlations were calculated using Spearman correlation coefficient r.
Results
HOOS scores and parameters of PBTs showed moderate to strong correlations (0.3 < r < 0.7). Correlation analysis between HOOS scores and biomechanical parameters revealed moderate to strong correlations for hip strength whereas correlations with gait parameters and balance were rather weak (r < 0.3). Moderate to strong correlations were also found between parameters of hip strength and 30CST.
Conclusion
For THA outcome assessment 12 months after surgery, our first results indicate that self-report measures or PBTs could be used. Analysis of hip strength also appears to be reflected in HOOS and PBT parameters and may be considered as an adjunct. Given the weak correlations with gait and balance parameters, we suggest that gait analysis and balance testing should be performed in addition to PROMs and PBTs as they may provide supplementary information, especially for THA patients that are at risk for falls.
The increasing diffusion of rapidly developing AI technologies led to the idea of the experiment to combine TRIZ-based automated idea generation with the natural language processing tool ChatGPT, using the chatbot to interpret the automatically generated elementary solution principles. The article explores the opportunities and benefits of a novel AI-enhanced approach to teaching systematic innovation, analyses the learning experience, identifies the factors that affect students' innovation and problem-solving performance, and highlights the main difficulties students face, especially in interdisciplinary problems.
Im Zuge der Machbarkeitsstudie „BubbleMeth“ (FKZ BWFE310091) wurde die Machbarkeit der biologischen Methanisierung in einem neukonzipierten innovativen Pilot-Reaktor, basierend auf einer Gegenstromblasensäule mit separatem Entgasungs-Reaktor, sowohl für den Betrieb in der biologischen in-situ als auch der ex-situ Methanisierung demonstriert.
Die Pilot-Anlage besteht aus einer Gegenstromblasensäule und einem separaten Entgasungs-Reaktor und wurde an der Hochschule Offenburg geplant und gebaut. Die beiden Reaktor-Säulen haben jeweils eine Höhe von 10 m, einen Säulendurchmesser von 0,3 m und ein Gesamtreaktionsvolumen von etwa 1,1 m3. Der Gaseintrag erfolgt über Sinterplatten am Boden der Gegenstromblasensäule. In dieser Begasungssäule strömt die Flüssigkeit in entgegengesetzter Richtung zu den aufsteigenden Gasblasen und reichert sich durch den am Säulenfuß vorliegenden hydraulischen Druck zunehmend mit gelöstem Gas an. Die Säule, in die das Eduktgas am Säulenboden eingetragen wird, ist in Abbildung 1 auf der rechten Seite dargestellt und befindet sich auf der Saugseite einer Pumpe. Bei einer etwa 9,5 m hohen Wassersäule erhöht sich der Absolutdruck am Säulenboden auf etwa 1,95 bar, womit sich die Löslichkeit einer beliebigen Gaskomponente im Vergleich zum Atmosphärendruck bei konstanter Temperatur im Gleichgewicht gemäß dem Henry’schen Gesetz näherungsweise verdoppelt. Dieser Effekt wird genutzt, um die Verfügbarkeit von gelöstem Wasserstoff für die bei der biologischen Methanisierung katalytisch wirkenden hydrogenothrophen Archaeen zu erhöhen. Durch die Zirkulation der Flüssigkeit und den damit erreichten Druckwechsel wird auf der Seite des Entgasungs-Reaktors ein Ausgasen der relativ zum Atmosphärendruck übersättigten Gaskomponente ermöglicht. Durch die Zirkulation der Flüssigkeit über zwei Säulen wird außerdem die räumliche Trennung des Eduktgaseintrages und der Produktgasabtrennung erreicht.
Die in-situ Methanisierung wurde in der Machbarkeitsstudie bis zu einer organischen Beladungsrate von 0,94 kg m-3 d-1 realisiert. Die erwartete Biogasbildungsrate (BGBR) bei vollständiger Umsetzung des Glucose/Fructose-Substrates zu Methan und CO2 lag bei ca. 0,686 m3 m-3 d-1. Die gemessene BGBR erreichte 0,61 ± 0,03 m3 m-3 d-1. Die geringe Abweichung kann auf eine zusätzliche Nutzung des Substrates für den Erhaltungsstoffwechsel des gesamten biologischen Systems zurückgeführt werden. Der maximale volumetrische H2-Eintrag betrug während der in-situ Methanisierung 0,785 m3 m-3 d-1 und ist dabei bezogen auf das gesamte Reaktionsvolumen von ca. 1,1 m3 in beiden Reaktorkolonnen. Das eingesetzte H2:CO2-Verhältnis lag bei 2,3, um einen vollständigen CO2-Umsatz und eine damit verbundene Verschiebung des pH-Wertes in den alkalischen Bereich bei der in-situ Methanisierung zu vermeiden. Die Produktgaszusammensetzung lag stabil bei ca. 80 Vol.% CH4, 18 Vol.% CO2 und geringen Mengen an Stickstoff, die im Wesentlichen aus der manuellen Entnahme der Gasproben resultieren, und entsprach der erwarteten Zusammensetzung bei dem vorgegebenen H2:CO2-Verhältnis.
Im Anschluss an die Untersuchungsphase der in-situ Methanisierung wurde der Prozess auf die ex-situ Methanisierung umgestellt. Dazu wurde die OLR schrittweise reduziert und gleichzeitig der Eintrag von CO2 aus einer Druckgasflasche erhöht. Die ex-situ Methanisierung wurde im Rahmen der Machbarkeitsstudie bis zu einem volumenspezifischen CO2-Eintrag bezogen auf das Gesamtreaktionsvolumen von 1,1 m3 von 0,563 m3 CO2 m-3 d-1 durchgeführt.
Der maximale volumetrische H2-Eintrag betrug während der ex-situ Methanisierung 2,168 m3 m-3 d-1. Das eingesetzte H2:CO2-Verhältnis lag bei 3,6 bis 3,9. Die Produktgaszusammensetzung lag stabil bei ca. 91 Vol.% CH4, 8 Vol.% CO2 und geringen Mengen an Stickstoff, und entsprach der erwarteten Zusammensetzung bei dem vorgegebenen H2:CO2-Verhältnis.
Besonders bemerkenswert war, dass sowohl bei der in-situ als auch der ex-situ Methanisierung und den jeweils in der Machbarkeitsstudie eingesetzten maximalen volumetrischen H2-Einträge weder im austretenden Produktgas am Entgasungsreaktor noch im rezirkulierten Gas am Kopf des Begasungsreaktors Wasserstoff nachzuweisen war. Damit besteht großes Potenzial für eine weitere Steigerung der Methanbildungsrate. Aus diesem Grund sollen die Arbeiten zur biologischen Methanisierung in einem Innovationsprojekt fortgeführt werden. Die Anlage soll hinsichtlich ihrer Eignung in einer relevanten Einsatzumgebung zur Methanisierung von in Biogas enthaltenem CO2-bewertet werden. Dazu soll die Anlage außerdem mit einem preiswerten alkalischen Elektrolyseur kombiniert werden, um das Verfahren so kostengünstig wie möglich zu gestalten. Dieser Elektrolyseur soll in Anlehnung an die fluktuierende Energiebereitstellung Erneuerbarer Energien zyklisch betrieben werden und dabei vor allem zu Zeiten günstiger Spotmarktpreise in Betrieb sein.
Enhancing engineering creativity with automated formulation of elementary solution principles
(2023)
The paper describes a method for the automated formulation of elementary creative stimuli for product or process design at different levels of abstraction and in different engineering domains. The experimental study evaluates the impact of structured automated idea generation on inventive thinking in engineering design and compares it with previous experimental studies in educational and industrial settings. The outlook highlights the benefits of using automated ideation in the context of AI-assisted invention and innovation.
Lithium-ion batteries exhibit slow voltage dynamics on the minute time scale that are usually associated with transport processes. We present a novel modelling approach toward these dynamics by combining physical and data-driven models into a Grey-box model. We use neural networks, in particular neural ordinary differential equations. The physical structure of the Grey-box model is borrowed from the Fickian diffusion law, where the transport domain is discretized using finite volumes. Within this physical structure, unknown parameters (diffusion coefficient, diffusion length, discretization) and dependencies (state of charge, lithium concentration) are replaced by neural networks and learnable parameters. We perform model-to-model comparisons, using as training data (a) a Fickian diffusion process, (b) a Warburg element, and (c) a resistor-capacitor circuit. Voltage dynamics during constant-current operation and pulse tests as well as electrochemical impedance spectra are simulated. The slow dynamics of all three physical models in the order of ten to 30 min are well captured by the Grey-box model, demonstrating the flexibility of the present approach.
A novel peptidyl-lys metalloendopeptidase (Tc-LysN) from Tramates coccinea was recombinantly expressed in Komagataella phaffii using the native pro-protein sequence. The peptidase was secreted into the culture broth as zymogen (~38 kDa) and mature enzyme (~19.8 kDa) simultaneously. The mature Tc-LysN was purified to homogeneity with a single step anion-exchange chromatography at pH 7.2. N-terminal sequencing using TMTpro Zero and mass spectrometry of the mature Tc-LysN indicated that the pro-peptide was cleaved between the amino acid positions 184 and 185 at the Kex2 cleavage site present in the native pro-protein sequence. The pH optimum of Tc-LysN was determined to be 5.0 while it maintained ≥60% activity between pH values 4.5—7.5 and ≥30% activity between pH values 8.5—10.0, indicating its broad applicability. The temperature maximum of Tc-LysN was determined to be 60 °C. After 18 h of incubation at 80 °C, Tc-LysN still retained ~20% activity. Organic solvents such as methanol and acetonitrile, at concentrations as high as 40% (v/v), were found to enhance Tc-LysN’s activity up to ~100% and ~50%, respectively. Tc-LysN’s thermostability, ability to withstand up to 8 M urea, tolerance to high concentrations of organic solvents, and an acidic pH optimum make it a viable candidate to be employed in proteomics workflows in which alkaline conditions might pose a challenge. The nano-LC-MS/MS analysis revealed bovine serum albumin (BSA)’s sequence coverage of 84% using Tc-LysN which was comparable to the sequence coverage of 90% by trypsin peptides.
This article presents the development, parameterization, and experimental validation of a pseudo-three-dimensional (P3D) multiphysics aging model of a 500 mAh high-energy lithium-ion pouch cell with graphite negative electrode and lithium nickel manganese cobalt oxide (NMC) positive electrode. This model includes electrochemical reactions for solid electrolyte interphase (SEI) formation at the graphite negative electrode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration and the reactions kinetics are described with an Arrhenius-type rate law. Good agreement of model predictions with galvanostatic charge/discharge measurements and electrochemical impedance spectroscopy is observed over a wide range of operating conditions. The model allows to quantify capacity loss due to cycling near beginning-of-life as function of operating conditions and the visualization of aging colormaps as function of both temperature and C-rate (0.05 to 2 C charge and discharge, −20 °C to 60 °C). The model predictions are also qualitatively verified through voltage relaxation, cell expansion and cell cycling measurements. Based on this full model, six different aging indicators for determination of the limits of fast charging are derived from post-processing simulations of a reduced, pseudo-two-dimensional isothermal model without aging mechanisms. The most successful aging indicator, compared to results from the full model, is based on combined lithium plating and SEI kinetics calculated from battery states available in the reduced model. This methodology is applicable to standard pseudo-two-dimensional models available today both commercially and as open source.
Phytases are widely used food and feed enzymes to improve phosphate availability and reduce anti-nutritional factors. Despite the benefits, enzyme usage is restricted by the harsh conditions in a gastrointestinal tract (pH 2–6) and feed pelleting conditions at high temperatures (60–90 °C). The commercially available phytase Quantum® Blue has been immobilized as CLEAs using glutardialdehyde and soy protein resulting in a residual activity of 33%. The influence of the precipitating agent, precipitant concentration, cross-linker concentration and cross-linking time, sodium borohydride as well as the proteic feeders gluten, soy protein and bovine serum albumin (BSA) has been optimized. The best conditions were 90% (v/v) ethyl lactate as precipitating reagent, 100 mM glutardialdehyde and a soy protein concentration of 227 mg/L with a cross-linking time of 1 h. The intrinsically stable phytase remained its high thermal stability and temperature optimum. The phytase-CLEA achieved a 425% increase of residual activity under harsh acidic conditions between pH 2.2 and 3.5 compared to the free enzyme. The free and immobilized phytase were deployed in an in vitro assay simulating the acidic conditions in the gizzard of poultry at pH 2. The hydrolysis of phytate was monitored using a novel high-performance thin-layer chromatography (HPTLC) analysis and DAD scanner to study the InsPx fingerprint. All lower inositol phosphate pools (InsP1–InsP6) and free phosphate were separated and analyzed. The phytase-CLEA efficiently released 80% of the total phosphate within 180 min, whereas the free enzyme only released 6% in the same time under the same conditions.
Die Erfindung betrifft eine Vorrichtung zur biologischen Methanisierung von CO und/oder CO2 mittels methanogener Mikroorganismen durch Umsetzung von H2 und CO und/oder CO2, die eine Begasungskolonne und eine Entgasungskolonne, jeweils mit
einer Bodenseite und einer der Bodenseite gegenüberliegenden oberen Seite, ein in der Begasungskolonne und der Entgasungskolonne bereitgestelltes Medium mit methanogenen Mikroorganismen, eine Zuführeinrichtung zum Zuführen eines H2 enthaltenden Gases in das Medium der Begasungskolonne, wobei die Zuführeinrichtung im Bereich der Bodenseite der Begasungskolonne angeordnet ist, eine Abführeinrichtung zum Abführen eines CH4 enthaltenden Gases aus der Entgasungskolonne, eine Verbindungsleitung zwischen Begasungskolonne und Entgasungskolonne im Bereich der Bodenseiten, eine Pumpe zum Überführen von Medium über die Verbindungsleitung von der Begasungskolonne in die Entgasungskolonne, und eine Rückführleitung zwischen der Begasungskolonne und der Entgasungskolonne im Bereich der oberen Seiten zum Rückführen von Medium
aus der Entgasungskolonne in die Begasungskolonne aufweist. Die Erfindung betrifft auch ein Verfahren zur biologischen Methanisierung von CO und/oder CO2 in einer Vorrichtung mittels methanogener Mikroorganismen als Teil eines in der Vorrichtung bereitgestellten Mediums, wobei das Medium in einem Kreislauf über eine Begasungskolonne und eine Entgasungskolonne geführt wird, wobei die Kolonnen jeweils über eine Verbindungsleitung im Bereich ihrer Bodenseiten und über eine Rückführleitung im Bereich der den Bodenseiten gegenüberliegenden oberen Seiten miteinander verbunden sind, worin das Medium sich in der Begasungskolonne absteigend und in der Entgasungskolonne aufsteigend bewegt, worin dem Medium im Bereich der Bodenseite der Begasungskolonne ein H2 enthaltendes Gas zugeführt wird.
Predictive control has great potential in the home energy management domain. However, such controls need reliable predictions of the system dynamics as well as energy consumption and generation, and the actual implementation in the real system is associated with many challenges. This paper presents the implementation of predictive controls for a heat pump with thermal storage in a real single-family house with a photovoltaic rooftop system. The predictive controls make use of a novel cloud camera-based short-term solar energy prediction and an intraday prediction system that includes additional data sources. In addition, machine learning methods were used to model the dynamics of the heating system and predict loads using extensive measured data. The results of the real and simulated operation will be presented.
Purpose
To (1) identify neuromuscular and biomechanical injury risk factors in elite youth soccer players and (2) assess the predictive ability of a machine learning approach.
Material and Methods
Fifty-six elite male youth soccer players (age: 17.2 ± 1.1 years; height: 179 ± 8 cm; mass: 70.4 ± 9.2 kg) performed a 3D motion analysis, postural control testing, and strength testing. Non-contact lower extremities injuries were documented throughout 10 months. A least absolute shrinkage and selection operator (LASSO) regression model was used to identify the most important injury predictors. Predictive performance of the LASSO model was determined in a leave-one-out (LOO) prediction competition.
Results
Twenty-three non-contact injuries were registered. The LASSO model identified concentric knee extensor peak torque, hip transversal plane moment in the single-leg drop landing task and center of pressure sway in the single-leg stance test as the three most important predictors for injury in that order. The LASSO model was able to predict injury outcomes with a likelihood of 58% and an area under the ROC curve of 0.63 (sensitivity = 35%; specificity = 79%).
Conclusion
The three most important variables for predicting the injury outcome suggest the importance of neuromuscular and biomechanical performance measures in elite youth soccer. These preliminary results may have practical implications for future directions in injury risk screening and planning, as well as for the development of customized training programs to counteract intrinsic injury risk factors. However, the poor predictive performance of the final model confirms the challenge of predicting sports injuries, and the model must therefore be evaluated in larger samples.
Photovoltaic-heat pump (PV-HP) combinations with battery and energy management systems are becoming increasingly popular due to their ability to increase the autarchy and utilization of self-generated PV electricity. This trend is driven by the ongoing electrification of the heating sector and the growing disparity between growing electricity costs and reducing feed-in tariffs in Germany. Smart control strategies can be employed to control and optimize the heat pump operation to achieve higher self-consumption of PV electricity. This work presents the evaluation results of a smart-grid ready controlled PV-HP-battery system in a single-family household in Germany, using 1-minute-high-resolution field measurement data. Within 12 months evaluation period, a self-consumption of 43% was determined. The solar fraction of the HP amounts to 36%, enabled also due to higher set temperatures for space heating and domestic hot water production. Accordingly, the SPF decreases by 4.0% the space heating and by 5.7% in the domestic hot water mode. The combined seasonal performance factor for the heat pump system increases from 4.2 to 6.7, when only considering the electricity taken from the grid and disregarding the locally generated electricity supplied from photovoltaic and battery units.
Photovoltaic thermal (PVT) technology has been drawing attention recently. Electrification of the heating sector with heat pumps run by carbon-free electricity sources like photovoltaics is setting the ground for the interest. This article gives insight into PVT technologies and collector designs according to application and operating temperatures. For most conventional designs, examples like prototypes from Research & Development projects are presented. In addition, commercial products are listed along these categories, and the influence on the gross thermal and electrical yield is depicted based on Solar Keymark certification data. The process of certification is presented in a comprehensive way, showing current limitations, giving an outlook on the most recent approach for enhanced procedures and specifications. Finally, different system layouts are presented, and examples from installations combined with a heat pump are given with their specific performances. Real performance data of several PVT installations are compared to conventional heat pump systems. The identified seasonal performance factors are in a range from 3.4 to 4.2 and in between air source and ground source heat pumps. Continuous monitoring and derived data are enablers to discover the decisive influence of the system layout and dimensioning on performance indicators like, for example, operating temperatures over the year.
Purpose
To summarize the mechanical loading of the spine in different activities of daily living and sports.
Methods
Since the direct measurement is not feasible in sports activities, a mathematical model was applied to quantify spinal loading of more than 600 physical tasks in more than 200 athletes from several sports disciplines. The outcome is compression and torque (normalized to body weight/mass) at L4/L5.
Results
The data demonstrate high compressive forces on the lumbar spine in sport-related activities, which are much higher than forces reported in normal daily activities and work tasks. Especially ballistic jumping and landing skills yield high estimated compression at L4/L5 of more than ten times body weight. Jumping, landing, heavy lifting and weight training in sports demonstrate compression forces significantly higher than guideline recommendations for working tasks.
Conclusion
These results may help to identify acute and long-term risks of low back pain and, thus, may guide the development of preventive interventions for low back pain or injury in athletes.
Appraising the Methodological Quality of Sports Injury Video Analysis Studies: The QA-SIVAS Scale
(2023)
Background
Video analysis (VA) is commonly used in the assessment of sports injuries and has received considerable research interest. Until now, no tool has been available for the assessment of study quality. Therefore, the objective of this study was to develop and evaluate a valid instrument that reliably assesses the methodological quality of VA studies.
Methods
The Quality Appraisal for Sports Injury Video Analysis Studies (QA-SIVAS) scale was developed using a modified Delphi approach including expert consensus and pilot testing. Reliability was examined through intraclass correlation coefficient (ICC3,1) and free-marginal kappa statistics by three independent raters. Construct validity was investigated by comparing QA-SIVAS with expert ratings by using Kendall’s tau analysis. Rating time was studied by applying the scale to 21 studies and computing the mean time for rating per study article.
Results
The QA-SIVAS scale consists of an 18-item checklist addressing the study design, data source, conduct, report, and discussion of VA studies in sports injury research. Inter- and intra-rater reliability were excellent with ICCs > 0.97. Expert ratings revealed a high construct validity (0.71; p < 0.001). Mean rating time was 10 ± 2 min per article.
Conclusion
QA-SIVAS is a reliable and valid instrument that can be easily applied to sports injury research. Future studies in the field of VA should adhere to standardized methodological criteria and strict quality guidelines.