Optimization of energetic refurbishment roadmaps for multi-family buildings utilizing heat pumps
(2023)
A novel methodology for calculating optimized refurbishment roadmaps is developed in this paper. The aim of the roadmaps is to determine when and how should which component of the building envelope and heat generation system be refurbished to achieve the lowest net present value. The integrated optimization approach couples a particle swarm optimization algorithm with a dynamic building simulation of the building envelope and the heat supply system. Due to a free selection of implementation times and refurbishment depth, the optimization method achieves the lowest net present value and high CO2 reduction and is therefore an important contribution to achieve climate neutrality in the building stock.
The method is exemplarily applied to a multi-family house built in 1970. In comparison to a standard refurbishment roadmap, cost savings of 6–16 % and CO2 savings of 6–59 % are possible. The sensitivity of the refurbishment roadmap measures is analyzed on the basis of a parametric analysis. Robust optimization results are obtained with a mean refurbishment level of approx. 50 kWh/m2/a of the building envelope. The preferred heat generation system is a bivalent brine-heat pump system with a share of 70 % of the heat load being covered by the electric heat pump.
Experimental Investigation of the Air Exchange Effectiveness of Push-Pull Ventilation Devices
(2020)
The increasing installation numbers of ventilation units in residential buildings are driven by legal objectives to improve their energy efficiency. The dimensioning of a ventilation system for nearly zero energy buildings is usually based on the air flow rate desired by the clients or requested by technical regulations. However, this does not necessarily lead to a system actually able to renew the air volume of the living space effectively. In recent years decentralised systems with an alternating operation mode and fairly good energy efficiencies entered the market and following question was raised: “Does this operation mode allow an efficient air renewal?” This question can be answered experimentally by performing a tracer gas analysis. In the presented study, a total of 15 preliminary tests are carried out in a climatic chamber representing a single room equipped with two push-pull devices. The tests include summer, winter and isothermal supply air conditions since this parameter variation is missing till now for push-pull devices. Further investigations are dedicated to the effect of thermal convection due to human heat dissipation on the room air flow. In dependence on these boundary conditions, the determined air exchange efficiency varies, lagging behind the expected range 0.5 < εa < 1 in almost all cases, indicating insufficient air exchange including short-circuiting. Local air exchange values suggest inhomogeneous air renewal depending on the distance to the indoor apertures as well as the temperature gradients between in- and outdoor. The tested measurement set-up is applicable for field measurements.