Refine
Year of publication
Document Type
- Conference Proceeding (14)
- Contribution to a Periodical (10)
- Report (6)
- Article (reviewed) (1)
Conference Type
- Konferenzartikel (14)
- Sonstiges (1)
Is part of the Bibliography
- yes (31) (remove)
Keywords
- Energy Management (3)
- Gebäudeklimatisierung (3)
- Energy Flexibility (2)
- Fotovoltaik (2)
- Klimatechnik (2)
- Sanierung (2)
- Smart Grid (2)
- Smart PV (2)
- Blockheizkraftwerke (1)
- Cogeneration (1)
Institute
Open Access
- Open Access (21)
- Bronze (11)
- Closed Access (6)
- Closed (3)
Schulgebäude im Liegenschaftsbestand vieler Kommunen treten in den vergangenen Jahren immer stärker ins Interesse der Öffentlichkeit. Viele der Gebäude stammen aus den 70-er oder 80-er Jahren und stehen im Rahmen der Bestandserhaltung für Modernisierungsmaßnahmen an. Insbesondere die hohen Betriebskosten für die Heizung hatten bisher Maßnahmen für den winterlichen Wärmeschutz in den Vordergrund gestellt. Die verstärkt auftretenden sommerlichen Extremtemperaturen an Unterrichtstagen der vergangenen Jahre zeigen zudem einen Handlungsbedarf im Bereich des sommerlichen Wärmeschutzes auf. Für die Aufgaben des Gebäudemanagements und zur Umsetzung eines energieeffizienten Gebäudebetriebs zeigen sich immer stärker die Vorteile einer vielseitig einsetzbaren Gebäudeautomation, die über zentrale Stellen des FM (z.B. Technisches Rathaus) zugänglich ist.
Encapsulant-free N.I.C.E. modules have strong ecological advantages compared to conventional laminated modules but suffer generally from lower electrical performance. Via long-term outdoor monitoring of fullsize industrial modules of both types with identical solar cells, we investigated if the performance difference remains constant over time and which parameters influence its value. After assessing about a full year’s data, two obvious levers for N.I.C.E. optimization are identified: The usage of textured glass and transparent adhesives on the module rear side. Also, the performance loss could be alleviated using tracking systems due to lower AOI values. Our measurements show additionally that N.I.C.E. module surfaces are in average about 2.5°C cooler compared to laminated modules. With these findings, we lay out a roadmap to reduce today’s LIV gap of about 5%rel by different optimizations.
Beim vorliegenden EnBau-Forschungsvorhaben sollte im Rahmen des ENOB-Förderprogramm ein Langzeitmonitoring des Neubauvorhabens Solar Info Center Freiburg (SIC) mit folgenden Untersuchungsschwerpunkten durchgeführt werden:
• Natürliche Klimatisierung mit Nachtlüftung und Einzelanbindung der Büroflächen
• Erdsondenkühlung für Seminarraum und Foyer
• Zonenweise Abschaltung und Optimierung des Heizbetriebs
• Optimierung Lüftungsbetrieb
• Sonnenschutzanlagen
• Analyse Stromverbrauch / Gesamtenergiebilanz
• Bedarfsanalyse der Nutzer
• Erstellung einer „Betriebsanleitung“ für das Gebäude
• Kurzzeitmessungen
• Gebäudeautomation
Die gesamte Projektlaufzeit wurde auf drei Jahre angesetzt die Datenerfassung für das Monitoring sollte dabei mindestens 2 Jahre betragen.
Das Projektvorhaben "Energienetzmanagement dezentraler KWK‐Anlagen mit diversen Verbraucherstrukturen", das vom Innovationsfonds der badenova AG & Co KG von Mai 2012 bis Juli 2016 unter der Fördernummer 2012‐09 gefördert wurde kann aus Sicht des Projektnehmers Hochschule Offenburg und seiner Partner Stadt Offenburg und G. und M. Zapf Energie GbR mbH als sehr erfolgreich umgesetztes Fördervorhaben bezeichnet werden. Während der ca. vier Jahre Projektlaufzeit konnten mehrere Reallabore geschaffen werden, die an die Eigenschaften eines Subnetzes in einem Smart Grid sehr nah herangeführt wurden. Alle Objekte bzw. Netzstrukturen verfügen über typische Komponenten eines Microgrids mit Energiequellen, Speichern und Senken. Auch wurde die Trigeneration als Netzvariante mit Strom‐ Wärme und Kältebereitstellung aufgegriffen und für Verteilnetzmodelle der Niederspannungsebene beschrieben. Ausgehend von einem Mikronetzmodell für jede Energieart kann hinter jeder Trafostation eine beliebig komplexe Energieversorgungsstruktur aufgespannt werden.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
Meeting the requirements of smart grids local, decentralized subnets will offer additional potentials to stabilize and compensate the utility grid mainly on the low voltage level. In a quite complex configuration these decentralized energy systems are combined power, heat and cooling power distributions. According to the regional and local availability of renewable energy sources advanced energy management concepts should consider climatic conditions as well as the state of the interacting utility grid and consumption profiles. The approach uses demonstrational setups to develop a forecast based energy management for trigeneration subnets by taking into account the running conditions of local electrical and thermal energy conversion units. This should lead to the best coverage of the demand and supporting/stabilizing the utility grid at the same time. For the first of three demonstrational projects the priorities of the subnet are given with the maximization of the CHP operation to substitute a major part of the heating and cooling power delivered by electric heaters or compression chillers.
A former remote area power supply was converted to a smart cogeneration subnet with combined heat and power to develop and validate a forecast based energy management at the University of Applied Sciences in Offenburg/Germany. Locally processed weather forecasts and forecasted demand profiles are integrated to allow a precise reaction to changes of fluctuating power sources, changes in scheduled demand profiles and to improve the energy efficiency of the supply. The management of the electrical and thermal storages is influenced by the forecasted energy contributions and the forecasted demand. Further approaches should improve the accuracy of forecasting algorithms and integrate parameter models gained of a detailed monitoring to realize predictive controllers.
Sustainable Aspects force a building manager to continuous observation of actual states and developments concerning building use, energy and media flows.In the presented approach a communication structure was built up to use different software applications and tools in order to optimize the operation of the building.
In this paper, a new method is demonstrated for online remote simulation of photovoltaic systems. The required communication technology for the data exchange is introduced and the methods of PV generator parameter extraction for the simulation models are analysed. The method shown for parameter extraction from the manufacturer data is especially useful for the commissioning procedure, where the measured installed power is transferred to standard test conditions using the simulation model and can then be easily compared with the design power. At a simulation accuracy of 2% using the software environment INSEL ® any problems with the PV generator can reliably be detected. Online simulation of a grid connected PV generator is then carried out during the operation of the photovoltaic plant. The visualisation includes both the monitored and the simulated online data sets, so that a very efficient fault detection scheme is available. The method is implemented and validated on several grid connected photovoltaic power plants in Germany. It is excellently suited to provide automatic and real time fault detection and significantly improve the commissioning procedure for photovoltaic plants of all sizes.
Intelligent und nachhaltig
(2013)
Getragen vom großen Erfolg der Veranstaltungen in den USA in 2008, weitete die Forschungsgruppe nachhaltige Energietechnik (net) seine Aktivitäten in den USA, aber auch in Kanada, Brasilien und in Ländern Osteuropas aus. Trotz anhaltender Wirtschaftskrise in 2009 herrscht in den USA, aber auch weltweit eine erfreulich optimistische Grundstimmung, wenn es um die Nutzung alternativer, erneuerbarer Energien und Fragen der effizienten Energieversorgung geht.
One of the major challenges impeding the energy transition is the intermittency of solar and wind electricity generation due to their dependency on weather changes. The demand-side energy flexibility contributes considerably to mitigate the energy supply/demand imbalances resulting from external influences such as the weather. As one of the largest electricity consumers, the industrial enterprises present a high demand-side flexibility potential from their production processes and on-site energy assets. In this direction, methods are needed with a focus on enabling the energy flexibility and ensure an active participation of such enterprises in the electricity markets especially with variable prices of electricity. This paper presents a generic model library for an industrial enterprise implemented with optimal control for energy flexibility purposes. The components in the model library represent the typical technical units of an industrial enterprise on material, media, and energy flow levels with their operative constraints. A case study of a plastic manufacturing plant using the generic model library is also presented, in which the results of two simulation with different electricity prices are compared and the behavior of the model can be assessed. The results show that the model provides an optimal scheduling of the manufacturing system according to the variations in the electricity prices, and ensures an optimal control for utilities and energy systems needed for the production.
Mit dem Anliegen, der sommerlichen Überhitzungssituation in Klassenzimmern wirksam entgegenzuwirken, ist die Stadt Offenburg an die Forschungsgruppe net der Hochschule Offenburg herangetreten. Im Sinn der Nachhaltigkeit sollten Maßnahmen ausgearbeitet und umgesetzt werden, die ohne aktive Kühlsysteme auskommen.
In vielen Schulgebäuden der Region südlicher Oberrhein - besonders bei solchen, die energetisch saniert wurden und wo der Schulbetrieb auf Ganztagsunterricht umgestellt wurde - zeigt sich seit Beginn dieses Jahrhunderts eine verstärkte Über-hitzungstendenz im Sommer. Im Rahmen der Initiative Forschungskooperation Hochschule/Stadt für mehr Energieeffizienz beim Betrieb öffentlicher Gebäude und Liegenschaften beauftragte die Stadt Offenburg die Forschungsgruppe nachhaltige Energietechnik (Forschungsgruppe net) der Hochschule Offenburg mit der Ausarbeitung eines Konzeptes für die natürliche Gebäudeklimatisierung in Klassenzimmern. Besonderes Augenmerk galt dabei neben bautechnischen Maßnahmen der Ge-bäudeautomation. Da ein vollautomatisierter Betrieb technisch und finanziell für viele kommunalen Betreiber unrealistisch ist, ist zudem die Einbindung der Nutzer und Mitarbeiter vor Ort unerlässlich. Die Ergebnisse aus dem Projekt stehen einer breiten Öffentlichkeit in Form eines Leitfadens zur Verfügung.
In vielen Schulgebäuden der Region südlicher Oberrhein zeigte sich seit Beginn dieses Jahrhunderts eine verstärkte Überhitzungstendenz. Besonders bei energetisch sanierten Schulen und durch die Umstellung des Schulbetriebs auf den Ganztagsunterricht zeigt sich eine stärkere Wärmebelastung durch die sommerlichen Temperaturen. Die Stadt Offenburg sah hier einen wichtigen Handlungsbedarf, um Klassenräume ohne den Einsatz energieintensiver Kältemaschinen thermisch zu entlasten. Durch einen deutlichen Anstieg beim Energieeinsatz für Kühlmaßnahmen würden die starken Einspareffekte bei den Heizkosten im Sommer neutralisiert. Interessant waren deshalb nachhaltige Lösungen die bei niedrigem Primärenergieeinsatz ein hohes Reduktionspotenzial bei der Kühllast bewirken. Verfahren der natürlichen Gebäudeklimatisierung führten in Zusammenarbeit mit der Forschungsgruppe nachhaltige Energietechnik der Hochschule Offenburg zu unterschiedlichen Nachtlüftungsstrategien zusammen mit ergänzenden Wärmeschutzmaßnahmen.
Der vorliegende Leitfaden „Natürliche Gebäudeklimatisierung in Klassenzimmern“ greift einen nachhaltigen Ansatz zur deutlichen Reduzierung der sommerlichen Wärmebelastung in Klassenzimmern auf. Insbesondere die ersten sechs Jahre des 21. Jahrhunderts zeigten verstärkt Überhitzungstendenzen in sehr vielen Schulgebäuden der Region südlicher Oberrhein. In Verbindung mit der Umstellung des Schulbetriebs auf die Ganztagsschule und der deutlichen Verstärkung der Überhitzungstendenz in sanierten Gebäuden, die mit einem modernisierten Wärmeschutz versehen sind, zeigte sich für die Stadt Offenburg ein wichtiger Handlungsbedarf auf.
Aus der Kooperation der Stadt Offenburg mit der Hochschule Offenburg entwickelten sich mehrere Maßnahmenpakete bestehend aus einer Kombination bekannter physikalischer Sachverhalte und Verfahren, die mit den Möglichkeiten einer Gebäudeautomation gekoppelt werden und durch Einbindung der Nutzer in das Betriebskonzept zu einem thermisch verbesserten Arbeits- und Lernklima führen.