Alle Materie strebt nach maximaler Unordnung. Diese Erkenntnis wird durch die thermodynamische Funktion der Entropie beschrieben. Auch bei jeglicher Art menschlichen Handelns wird die Entropie immer erhöht. Wird in der Technik Materie in geordnete Formen gebracht (z. B. beim Herstellen von Pfandflaschen), findet in diesem Produkt eine Entropieerniedrigung statt. Gleichzeitig wird aber an anderer Stelle die Unordnung beträchtlich vergrößert. Diese Entropieerhöhung nennen wir Abfall. Jede Entropieerhöhung ist mit dem Verbrauch wertvoller Ressourcen verbunden. Durch eine optimale Recyclingtechnik kann einer Entropieerhöhung von Materie entgegengearbeitet werden. Aber nur Recyclingraten von über 90 % erlauben eine wirksame Streckung der Ressourcen.
Vorrichtung (2) zur Analyse von Urin, umfassend: – eine Zuführ- und Abführeinrichtung (7), welche zur Zuführung einer bestimmten Urinmenge in eine wenigstens einen Analysebereich (8) aufweisende Analysekammer (9) eines Urinteststreifens (10) und zur Abführung einer bestimmten Urinmenge aus einer wenigstens einen Analysebereich (8) aufweisenden Analysekammer (9) eines Urinteststreifens (10) eingerichtet ist, wobei die Zuführ- und Abführeinrichtung (7) wenigstens ein bewegbar gelagertes Zuführ- und/oder Abführelement (28, 29) zum Zuführen einer bestimmten Urinmenge in einen Zuführbereich (33) der Analysekammer (9) des Urinteststreifens (10) und/oder zum Abführen einer bestimmten Urinmenge aus einem Abführbereich (34) der Analysekammer (9) des Urinteststreifens (10) aufweist, und – eine Erfassungseinrichtung (11), welche zur Erfassung einer zumindest abschnittsweisen Änderung wenigstens eines optisch erfassbaren Parameters, welcher sich in Abhängigkeit der Zusammensetzung einer diesen kontaktierenden Urinmenge optisch erfassbar verändert, des oder eines entsprechenden Analysebereichs (8) des oder eines entsprechenden Urinteststreifens (10) sowie zur Erzeugung einer Erfassungsinformation, welche wenigstens einen optisch erfassten Parameter des oder eines entsprechenden Analysebereichs (8) oder eine Änderung eines solchen beschreibt, eingerichtet ist.
Vorrichtung (2) zur Analyse von Urin, umfassend: – eine Zuführ- und Abführeinrichtung (7), welche zur Zuführung einer bestimmten Urinmenge in eine wenigstens einen Analysebereich (8) aufweisende Analysekammer (9) eines Urinteststreifens (10) und zur Abführung einer bestimmten Urinmenge aus einer wenigstens einen Analysebereich (8) aufweisenden Analysekammer (9) eines Urinteststreifens (10) eingerichtet ist, wobei die Zuführ- und Abführeinrichtung (7) wenigstens ein bewegbar gelagertes Zuführ- und/oder Abführelement (28, 29) zum Zuführen einer bestimmten Urinmenge in einen Zuführbereich (33) der Analysekammer (9) des Urinteststreifens (10) und/oder zum Abführen einer bestimmten Urinmenge aus einem Abführbereich (34) der Analysekammer (9) des Urinteststreifens (10) aufweist, und – eine Erfassungseinrichtung (11), welche zur Erfassung einer zumindest abschnittsweisen Änderung wenigstens eines optisch erfassbaren Parameters, welcher sich in Abhängigkeit der Zusammensetzung einer diesen kontaktierenden Urinmenge optisch erfassbar verändert, des oder eines entsprechenden Analysebereichs (8) des oder eines entsprechenden Urinteststreifens (10) sowie zur Erzeugung einer Erfassungsinformation, welche wenigstens einen optisch erfassten Parameter des oder eines entsprechenden Analysebereichs (8) oder eine Änderung eines solchen beschreibt, eingerichtet ist.
Vorrichtung (2) zur Analyse von Urin, umfassend: – eine Zuführ- und Abführeinrichtung (7), welche zur Zuführung einer bestimmten Urinmenge in eine wenigstens einen Analysebereich (8) aufweisende Analysekammer (9) eines Urinteststreifens (10) und zur Abführung einer bestimmten Urinmenge aus einer wenigstens einen Analysebereich (8) aufweisenden Analysekammer (9) eines Urinteststreifens (10) eingerichtet ist, wobei die Zuführ- und Abführeinrichtung (7) wenigstens ein bewegbar gelagertes Zuführ- und/oder Abführelement (28, 29) zum Zuführen einer bestimmten Urinmenge in einen Zuführbereich (33) der Analysekammer (9) des Urinteststreifens (10) und/oder zum Abführen einer bestimmten Urinmenge aus einem Abführbereich (34) der Analysekammer (9) des Urinteststreifens (10) aufweist, und – eine Erfassungseinrichtung (11), welche zur Erfassung einer zumindest abschnittsweisen Änderung wenigstens eines optisch erfassbaren Parameters, welcher sich in Abhängigkeit der Zusammensetzung einer diesen kontaktierenden Urinmenge optisch erfassbar verändert, des oder eines entsprechenden Analysebereichs (8) des oder eines entsprechenden Urinteststreifens (10) sowie zur Erzeugung einer Erfassungsinformation, welche wenigstens einen optisch erfassten Parameter des oder eines entsprechenden Analysebereichs (8) oder eine Änderung eines solchen beschreibt, eingerichtet ist.
A 2D-separation of 16 polyaromatic hydrocarbons (PAHs) according to the Environmental Protecting Agency (EPA) standard was introduced. Separation took place on a TLC RP-18 plate (Merck, 1.05559). In the first direction, the plate was developed twice using n-pentane at −20°C as the mobile phase. The mixture acetonitrile-methanol-acetone-water (12:8:3:3, v/v) was used for developing the plate in the second direction. Both developments were carried out over a distance of 43 mm. Further on in this publication, a specific and very sensitive indication method for benzo[a]pyrene and perylene was presented. The method can detect these hazardous compounds even in complicated PAH mixtures. These compounds can be quantified by a simple chemiluminescent reaction with a limit of detection (LOD) of 48 pg per band for perylene and 95 pg per band for benzo[a]pyrene. Although these compounds were separated from all other PAHs in the standard, a separation of both compounds was not possible from one another. The method is suitable for tracing benzo[a]pyrene and/or perylene. The proposed chemiluminescence screening test on PAHs is extremely sensitive but may indicate a false positive result for benzo[a]pyrene.
We present a two-dimensional (2D) planar chromatographic separation method for phytoestrogenic active compounds on RP-18 W (Merck, 1.14296) phase. It could be shown that an ethanolic extract of liquorice (Glycyrrhiza glabra) roots contains four phytoestrogenic active compounds. As solvent, in the first direction, the mix of hexane, ethyl acetate, and acetone (45:15:10, v/v) was used, and, in the second direction, that of acetone and water (15:10, v/v) was used. After separation, a modified yeast estrogen screen (YES) test was applied, using the yeast strain Saccharomyces cerevisiae BJ3505. The test strain (according to McDonnell) contains the estrogen receptor. Its activation by estrogen active compounds is measured by inducing the reporter gene lacZ which encodes the enzyme β-galactosidase. This enzyme activity is determined on plate by using the fluorescent substrate MUG (4-methylumbelliferyl-β-d-galactopyranoside). The enzyme can also hydrolyse X-β-Gal (5-bromo-4-chloro-3-indoxyl-β-d-galactopyranosid) into β-galactose and 5-bromo-4-chloro-3-indoxyl. The indoxyl compound is oxidized by oxygen forming the deep-blue dye 5,5β-dibromo-4,4β-dichloro-indigo which allows to detect phytoestrogenic activity more specific in the presence of native fluorescing compounds.
We present a two-dimensional (2D) planar chromatographic separation of estrogenic active compounds on RP-18 W (Merck, 1.14296) phase. A mixture of 8 substances was separated using a solvent mix consisting of hexane, ethyl acetate, acetone (55:15:10, v/v) in the first direction and of acetone and water (15:10, v/v) in the second direction. Separation was performed on an RP-18 W plate over a distance of 70 mm. This 2D-separation method can be used to quantify 17α-ethinylestradiol (EE2) in an effect-directed analysis, using the yeast strain Saccharomyces cerevisiae BJ3505. The test strain (according to McDonnell) contains the estrogen receptor. Its activation by estrogen active compounds is measured by inducing the reporter gene lacZ which encodes the enzyme β-galactosidase. This enzyme activity is determined on plate by using the fluorescent substrate MUG (4-methylumbelliferyl-β-d-galactopyranoside).
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows many advantages when compared to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. For visualisation of the sample distribution on a HPTLC-plate we developed a new and sturdy HPTLC-scanner. The scanner allows simultaneous registrations of spectra in a range from 198 nm to 612 nm with a spectral resolution of better than 0.8 nm. The on-plate spatial resolution is better than 160 μm. The measurement of 450 spectra in one separation track does not need more than two minutes. The new diode-array scanner offers a fast survey over a TLC-separation and makes various chemometric applications possible. For compound identification a cross-correlation function is described to compare UV sample spectra with appropriate library data. The cross-correlation function herein described can also be used for purity testing. Unresolved peaks can be virtually separated by use of a least squares fit algorithm. In summary, the diode arry system delivers much more information than the commonly used TLC-scanner.
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
The main focus of this chapter is the theoretical and instrumental processes that underpin densitometric methods widely used in thin-layer chromatography (TLC). Densitometric methods include UV–vis, luminescence, and fluorescence optical measurements as well as infrared and Raman spectroscopic measurements. The chapter is divided in two general parts: a theoretical part and a practical part. The systems for direct radioactivity measurements and the combination of TLC with mass spectrometry are also discussed. All these systems allow measuring an intensity distribution directly on a TLC plate. We call this “in situ detection” because no analyte is removed from the plate.
The main focus of this chapter is the theoretical and instrumental processes that underpin densitometric methods widely used in thin-layer chromatography (TLC). Densitometric methods include UV–vis, luminescence and fluorescence optical measurements as well as infrared and Raman spectroscopic measurements. The chapter is divided in two general parts: a theoretical part and a practical part. The systems for direct radioactivity measurements and the combination of TLC with mass spectrometry are also discussed. All these systems allow measuring an intensity distribution directly on a TLC plate. We call this “in situ detection” because no analyte is removed from the plate.
Vorgestellt wird die Dioden-Array-Dünnschichtchromatographie als eine moderne und preiswerte Messmethode zur densitometrischen Erfassung von Substanzen auf einer DC- oder einer HPTLC-Platte. Sicher identifizierbar sind auch Substanzen mit schwachem Chromophor. Die Kubelka-Munk-Gleichung beschreibt einen linearen Zusammenhang zwischen Remissionslicht und lichtabsorbierender Stoffmenge auf der Platte. Die Auswertung im Spektralbereich von 316 bis 334 nm zeigt den Zusammenhang zwischen transformiertem Messsignal und aufgetragener Substanzmasse. Die schnelle Aufnahme von UV/vis-Spektren eröffnet der HPTLC den gesamten Bereich der Methodenvalidierung auf dem Niveau, auf welchem heute die HPLC-Analytik durchgeführt wird.
Improved separation of highly toxic contact herbicides paraquat (1,1′-dimethyl-4-4′-bipyridinium), diquat (6,7-dihydrodipyridol[ 1,2-a:2′,1′-c]pyrazine-5,8-di-ium), difenzoquat (1,2-dimethyl-3,5-diphenyl-1H-pyrazolium-methyl sulfate), mepiquat (1,1-dimethyl-piperidinium), and chloromequat (2-chloroethyltrimethylammonium) were presented by high-performance thin-layer chromatography (HPTLC). The quantification is based on a derivatization reaction, using sodium tetraphenylborate. Measurements were made in the wavelength range from 500 to 535 nm, using a light-emitting diode (LED) for excitation purposes, which emits very dense light at 365 nm. For calculations, a new theory of standard addition method was used, thus leading to a minimal error if exactly the same amount of sample content is added as a standard. The method provides a fast and inexpensive approach to quantification of the five most important quats used for plant protection purposes. The method works reliably because it takes into account losses during pre-treatment procedure. The method meets the European legislation limits for paraquat and diquat in drinking water according to United States Environmental Protection Agency (US EPA) method 549.2 which are 680 ng L−1 for paraquat and 720 ng L−1 for diquat. The method of standard addition in planar chromatography can be beneficially used to reduce systematic errors. Although recovery rates of 33.7% to 65.2% are observed, calculated contents according to the method of standard addition lie between 69% and 127% of the theoretical amounts.
We present a video-densitometric quantification method for the pain killer known as diclofenac and ibuprofen. These non-steroidal anti-inflammatory drugs were separated on cyanopropyl bonded plates using CH2Cl2, methanol, cyclohexane (95 + 5 + 40, v/v) as mobile phase. The quantification is based on a bio-effective-linked analysis using Vibrio fisheri bacteria. Within 10 min a CCD-camera registered the white light of the light-emitting bacteria. Diclofenac and ibuprofen effectively suppressed the bacterial light emission which can be used for quantification within a linear range of 10 to 2000 ng. The detection limit for ibuprofen is 20 ng and the limit of quantification 26 ng per zone. Measurements were carried out using a 16-bit ST-1603ME CCD camera with 1.56 megapixels (from Santa Barbara Instrument Group, Inc., Santa Barbara, USA). The range of linearity covers more than two magnitudes because the extended Kubelka-Munk expression is used for data transformation. The separation method is inexpensive, fast, and reliable.
High-performance thin-layer chromatography (HPTLC), as the modern form of TLC (thin-layer chromatography), is suitable for detecting pharmaceutically active compounds over a wide polarity range using the gradient multiple development (GMD) technique. Diode-array detection (DAD) in conjunction with HPTLC can simultaneously acquire ultraviolet‒visible (UV‒VIS) and fluorescence spectra directly from the plate. Visualization as a contour plot helps to identify separated zones. An orange peel extract is used as an example to show how GMD‒DAD‒HPTLC in seven different developments with seven different solvents can provide an overview of the entire sample. More than 50 compounds in the extract can be separated on a 6-cm HPTLC plate. Such separations take place in the biologically inert stationary phase of HPTLC, making it a suitable method for effect-directed analysis (EDA). HPTLC‒EDA can even be performed with living organism, as confirmed by the use of Aliivibrio fischeri bacteria to detect bioluminescence as a measure of toxicity. The combining of gradient multiple development planar chromatography with diode-array detection and effect-directed analysis (GMD‒DAD‒HPTLC‒EDA) in conjunction with specific staining methods and time-of-flight mass spectrometry (TOF‒MS) will be the method of choice to find new chemical structures from plant extracts that can serve as the basic structure for new pharmaceutically active compounds.
Die Weltwirtschaftskrise 2008 hat mit ihrer zeitweisen Verknappung von Acetonitril eindringlich gezeigt, dass man nicht nur auf eine einzige chromatographische Methode setzten sollte. Genau dies wird aber im Augenblick getan, denn Industrie und Forschung setzen mehrheitlich auf die High Performance Liquid Chromatography (HPLC) als die Trennmethode ihrer Wahl. Für viele Anwendungen in der Pharmazie, in der Umweltanalytik, der Lebensmittelanalytik, aber auch in der Inprozesskontrolle gibt es mit der Dünnschichtchromatografie eine Alternative.
Rudolf E. Kaiser
(2020)