Refine
Document Type
Conference Type
- Konferenzartikel (3)
Language
- English (13)
Is part of the Bibliography
- yes (13) (remove)
Keywords
- Akustik (1)
- Akustische Oberflächenwelle (1)
- Antenne (1)
- Applikation (1)
- Bioelement (1)
- Bluetooth Low Energy (1)
- FEM model (1)
- FSK Wake-Up (1)
- Formale Beschreibung (1)
- Integrierte Schaltung (1)
Institute
Open Access
- Closed Access (5)
- Open Access (4)
- Closed (2)
- Gold (1)
A simple model is introduced that describes the interaction of surface acoustic waves (SAWs) with a 2D periodic array of objects on the surface that give rise to internal resonances. Such objects may be high-aspect ratio structures like micro-pillars fabricated of a material different from that of the substrate. The model allows for an approximate determination of the band structure for the acoustic modes in such systems. Results are presented for the dependence on structural parameters of a total bandgap in the non-radiative regime of a semi-infinite substrate, and it is shown how the frequency and radiation damping of vibrational modes can be determined that are associated with defects in the periodic 2D array.
The growing demand for active medical implantable devices requires data and or power links between the implant and the outside world. Every implant has to be encapsulated from the body by a specific housing and one of the most common materials used is titanium or titanium alloy. Titanium thas the necessary properties in terms of mechanical and chemical stability and biocompatibility. However, its electrical conductivity presents a challenge for the electromagnetic transmission of data and power. The proposed paper presents a fast and practical method to determine the necessary transmission parameters for titanium encapsulated implants. Therefore, the basic transformer-transmission-model is used with measured or calculated key values for the inductances. Those are then expanded with correction factors to determine the behavior with the encapsulation. The correction factors are extracted from finite element method simulations. These also enable the analysis of the magnetic field distribution inside of the housing. The simulated transmission properties are very close to the measured values. Additionally, based on lumped elements and magnetic field distribution, the influential parameters are discussed in the paper. The parameter discussion describes how to enhance the transmitted power, data-rate or distance, or to reduce the size of the necessary coils. Finally, an example application demonstrates the usage of the methods.
A new RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (System on chip) for biomedical applications is presented here. The proposed SOC consists of an integrated 32 bit microcontroller, RFID/NFC frontend, sensor interface circuit, analog to digital converter and some peripherals such as timer, SPI interface and memory devices. An energy harvesting unit supplies the power required for the entire system for complete passive operation. The complete chip is realized on CMOS 0.18 μm technology with a chip area of 1.5 mm × 3.0 mm.
High-precision signal processing algorithm to evaluate SAW properties as a function of temperature
(2013)
This paper presents a signal processing algorithm which accurately evaluates the SAW properties of a substrate as functions of temperature. The investigated acoustic properties are group velocity, phase velocity, propagation loss, and coupling coefficient. With several measurements carried out at different temperatures, we obtain the temperature dependency of the SAW properties. The analysis algorithm starts by reading the transfer functions of short and long delay lines. The analysis algorithm determines the center frequency of the delay lines and obtains the delay time difference between the short and long delay lines. The extracted parameters are then used to calculate the acoustic properties of the SAW material. To validate the algorithm, its accuracy is studied by determining the error in the calculating delay time difference, center frequency, and group velocity.
Design of a Programmable Passive SoC for Biomedical Applications Using RFID ISO 15693/NFC5 Interface
(2018)
Low power, low cost inductively powered passive biotelemetry system involving fully customized RFID/NFC interface base SoC has gained popularity in the last decades. However, most of the SoCs developed are application specific and lacks either on-chip computational or sensor readout capability. In this paper, we present design details of a programmable passive SoC in compliance with ISO 15693/NFC5 standard for biomedical applications. The integrated system consists of a 32-bit microcontroller, a sensor readout circuit, a 12-bit SAR type ADC, 16 kB RAM, 16 kB ROM and other digital peripherals. The design is implemented in a 0.18 µm CMOS technology and used a die area of 1.52 mm × 3.24 mm. The simulated maximum power consumption of the analog block is 592 µW. The number of external components required by the SoC is limited to an external memory device, sensors, antenna and some passive components. The external memory device contains the application specific firmware. Based on the application, the firmware can be modified accordingly. The SoC design is suitable for medical implants to measure physiological parameters like temperature, pressure or ECG. As an application example, the authors have proposed a bioimplant to measure arterial blood pressure for patients suffering from Peripheral Artery Disease (PAD).
An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications
(2018)
Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit) for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying) signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μm CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 mm2. The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μW. The analog part of the design consumes only 36 μW, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM) is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches.
We present a novel approach that utilizes BLE packets sent from generic BLE capable radios to synthesize an FSK-(like) addressable wake-up packet. A wake-up receiver system was developed from off-the-shelf components to detect these packets. It makes use of two differential signal paths separated by passive band-pass filters. After the rectification of each channel a differential amplifier compares the signals and the resulting wake-up signal is evaluated by an AS3933 wake-up receiver IC. Overall, the combination of these techniques contributes to a BLE compatible wake-up system which is more robust than traditional OOK wake-up systems. Thus, increasing wake-up range, while still maintaining a low energy budget. The proof-of-concept setup achieved a sensitivity of -47.8 dBm at a power consumption of 18.5 uW during passive listening. The system has a latency of 31.8 ms with a symbol rate of 1437 Baud.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Polygeneration systems are a key technology for the reduction of primary energy usage and emissions. High costs, lack of flexibility and effort for parameterization hinder the wide usage of modeling tools during their conceptual design. This paper describes how planning tools can be structured for the conceptual design phase where only little information is available to the planner. A library concept was developed using the principles of object-oriented modeling to address the flexibility issue. With respect to cost and expandability, the open-source modeling language Modelica was chosen. Furthermore, easy-to-parameterize component models were developed. In addition to the improved library concept and novel component models, an easy-to-adapt control concept is proposed. The component models were validated and the applicability of the library was demonstrated by means of an example. It was shown that the data usually obtained from spec sheets are sufficient to parameterize the models. In addition to this, the control concept was approved.
Formal Description of Inductive Air Interfaces Using Thévenin's Theorem and Numerical Analysis
(2014)
With the development of new integrated circuits to interface radio frequency identification protocols, inductive air interfaces have become more and more important. Near field communication is not only able to communicate, but also possible to transfer power wirelessly and to build up passive devices for logistical and medical applications. In this way, the power management on the transponder becomes more and more relevant. A designer has to optimize power consumption as well as energy harvesting from the magnetic field. This paper discusses a model with simple equations to improve transponder antenna matching. Furthermore, a new numerical analysis technique is presented to calculate the coupling factors, inductions, and magnetic fields of multiantenna systems.
Rotation of an elastic medium gives rise to a shift of frequency of its acoustic modes, i.e., the time-period vibrations that exist in it. This frequency shift is investigated by applying perturbation theory in the regime of small ratios of the rotation velocity and the frequency of the acoustic mode. In an expansion of the relative frequency shift in powers of this ratio, upper bounds are derived for the first-order and the second-order terms. The derivation of the theoretical upper bounds of the first-order term is presented for linear vibration modes as well as for stable nonlinear vibrations with periodic time dependence that can be represented by a Fourier series.