Refine
Year of publication
- 2012 (47) (remove)
Document Type
- Conference Proceeding (27)
- Article (reviewed) (5)
- Article (unreviewed) (4)
- Patent (3)
- Part of a Book (2)
- Contribution to a Periodical (2)
- Working Paper (2)
- Book (1)
- Report (1)
Conference Type
- Konferenzartikel (19)
- Konferenz-Abstract (7)
- Sonstiges (1)
Is part of the Bibliography
- yes (47) (remove)
Keywords
- RoboCup (2)
- Signaltechnik (2)
- Aircraft (1)
- Arzneimittelprüfung (1)
- Asynchronmaschine (1)
- Attenuation (1)
- BLE (1)
- Batterie (1)
- Bildgebung (1)
- Brennstoffzelle (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (47) (remove)
Open Access
- Open Access (25)
- Closed (10)
- Bronze (7)
- Closed Access (7)
The suffix-free-prefix-free hash function construction and its indifferentiability security analysis
(2012)
In this paper, we observe that in the seminal work on indifferentiability analysis of iterated hash functions by Coron et al. and in subsequent works, the initial value (IV) of hash functions is fixed. In addition, these indifferentiability results do not depend on the Merkle–Damgård (MD) strengthening in the padding functionality of the hash functions. We propose a generic n-bit-iterated hash function framework based on an n-bit compression function called suffix-free-prefix-free (SFPF) that works for arbitrary IVs and does not possess MD strengthening. We formally prove that SFPF is indifferentiable from a random oracle (RO) when the compression function is viewed as a fixed input-length random oracle (FIL-RO). We show that some hash function constructions proposed in the literature fit in the SFPF framework while others that do not fit in this framework are not indifferentiable from a RO. We also show that the SFPF hash function framework with the provision of MD strengthening generalizes any n-bit-iterated hash function based on an n-bit compression function and with an n-bit chaining value that is proven indifferentiable from a RO.
In this paper, a complete passive transponder device has been discussed which is meant to monitor leakage in silicone breast implants. The passive tag operates in the HF frequency range of 13.56MHz using RFID ISO 15693 standard. The complete system consists of the transponder, reader and a PC. This paper focusses on the development of such a state of the art passive RFID transponder to monitor the wellness of the silicone breast implants periodically in order to detect leakage in the same. Keyword: RFID (Radio frequency identification device), EM (Electromagnetic) field, Passive Transponder, Silicone breast implants.
The Humboldt digital library (HDL) represents an innovative system to access the works and legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question about how to present interconnected data in an appropriate form using information technologies. The HDL has been created as a dynamic digital library with the capability of connecting multilingual and multimedia data from diverse online archives. Humboldt’s volumes have become available, but beyond that any relevant information related to the observations of Humboldt, even outside the works can become immediately accessible. This makes it possible to recognize natural changes and compare Humboldt’s descriptions with recent situations. The technology we have developed addresses the issues of sustainability and makes it possible to detect changes in the environment since the time of Humboldt’s observations.
Große Logistikunternehmen stehen in den letzten Jahren zunehmend vor neuen Herausforderungen. Zum einen steigt die Menge zu transportierender Güter jährlich, zum anderen entstanden durch Verschmelzungen großer Logistikunternehmen, wie z. B. Deutsche Post, Danzas und Exel oder UPS und Fritz, riesige Fahrzeugflotten, deren effiziente Planung die Unternehmen vor enorme Probleme stellt. Die einzige Möglichkeit, diese meist heterogenen, also aus vielen verschiedenen Verkehrsmitteln bestehenden Flotten mit herkömmlichen Mitteln effizient zu planen, ist die Aufteilung in (regionale) Geschäftsbereiche. Dadurch können viele Synergieeffekte nicht genutzt werden, was unter anderem zu unnötig hohen Transportkilometerleistungen und Leerfahrten führt. Im Rahmen des Forschungsprojekts Attractive (Programm IngenieurNachwuchs) wurden neue Algorithmen entwickelt, mit deren Hilfe dieOptimierung von Transportaufträgen unter realen Be-dingungen und in realistischen Größenordnungen möglich wird. In diesem Artikel wird kurz auf die Optimierung eingegangen, und dann werden die ersten gewonnenen Ergebnisse zusammengefasst.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
This paper analyzes the applicability of existing communication technology on the Smart Grid. In particular it evaluates how networks, e.g. Peer-to-Peer (P2P) and decentralized Virtual Private Network (VPN) can help set up an agent-based system. It is expected that applications on Smart Grid devices will become more powerful and be able to operate without a central control instance. We analyze which requirements agents and Smart Grid devices place on communication systems and validate promising approaches. The main focus is to create a logical overlay network that provides direct communication between network nodes. We provide a comparison of different approaches of P2P networks and mesh-VPNs. Finally the advantages of mesh-VPN for agent-based systems are worked out.
In sicherheitskritschen Systemen darf kein Stück Code im Produktionsbetrieb ablaufen, ohne vorher intensive Tests durchlaufen zu haben. Aber auch zur Qualitätssicherung muss Software getestet werden. Um die Codeüberdeckung zu prüfen, sind zusätzliche Prüf-Instruktionen im Quellcode erforderlich. Auf kleinen Systemen mit wenig RAM kann sich der Entwickler dann etwas einfallen lassen, damit das funktioniert.
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Capture threshold (CT) for transesophageal left atrial (LA) pacing (TLAP) and transesophageal left ventricular (LV) pacing (TLVP) with conventional cylindrical electrodes (CE) are higher than TLAP feeling threshold (FT). Purpose of the study was to evaluate focused TLAP CT and FT for supraventricular tachycardia (SVT) initiation and focused TLVP CT for cardiac resynchronisation therapy (CRT) simulation.
Methods: SVT initiation in patients (P) with palpitations (n=49, age 47 ± 17 years) was analysed during spontaneous rhythm and during focused bipolar TLAP with atrial constant current stimulus output, distal CE and three or seven 6 mm hemispherical electrodes (HE) (TO, Osypka AG, Rheinfelden, Germany). CRT simulation in heart failure P (n=75, age 62 ± 11 years) was evaluated by focused bipolar TLAP and/or TLVP with ventricular constant voltage stimulus output and different pacing mode.
Results: Focused electrical pacing field between CE and HE (n=28) allowed low threshold TLAP with 8.0 ± 2.6 mA CT at 9.9 ms stimulus duration (SD) which was lower than 9.2 ± 4.5 mA FT at 9.9 ms SD. Focused electrical pacing field between HE and HE (n=21) allowed low threshold TLAP with 8.1 ± 2.2 mA CT at 9.9 ms SD which was lower than 9.8 ± 5.0 mA FT at 9.9 ms SD. SVT initiation by programmed AAI TLAP was possible in 23 P and not possible in 26 P. CRT simulation was evaluated with TLAP and TLVP with VAT, D00 and V00 pacing mode and 95.5 ± 10.9 V TLVP CT at 4.0 ms SD.
Conclusions: Programmed focused AAI TLAP allowed initiation of SVT with very low CT and high FT and focused electrical pacing field between CE-HE and HE-HE.CRT simulation with focused TLAP and/or TLVP with VAT, D00 and V00 pacing mode may be a useful technique to detect responders to CRT.
Responder-rate in cardiac resynchronization therapy (CRT) of patients in sinus rhythm (SR) or atrial fibrillation (AF) mainly depends on accurat selection, optimal position of the left ventricular electrode and individualization of hemodynamical parameters of the implanted biventricular pacing system during follow-up. High resolution esophageal left heart electrocardiography offers a quick and semi-invasive approach to the electrical activity of left atrium and left ventricle. It was used in 62 heart failure patients in sinus rhythm and 11 in atrial fibrillation after implantation of CRT systems to compare the semi-invasive interventricular conduction delay (IVCDE) with QRS width. In all of the patients, guideline decision for CRT was linked with IVCDE of about 40ms and up. From logical point of view, IVCDE provides the minimal target interval for the left ventricular electrode placement in order to exclude non-responders. Esophageal measurement of interatrial conduction intervals in VDD and DDD pacing was utilized to individualize the AV delay and to exclude adverse hemodynamic effects.
The invention relates to a container (1) for a liquid medium (3), in particular a blood bag, comprising a flexible outer wall (5) and a device (13) connected to the container (1) for acquiring and/or storing data. According to the invention, the device (13) for acquiring and/or storing data is arranged within the flexible outer wall (5), wherein positioning means (15) are provided which hold the device (13) for acquiring and/or storing data in a floating manner in the liquid medium when the container (1) is filled with said liquid medium (3), and wherein the device (13) or the device (13) and the positioning means (15) are designed such that the mass of liquid medium (3) which is displaced in each case is essentially equal to the mass of the device (13) or to the mass of the device (13) and the positioning means (15).
Die Erfindung betrifft ein Behältnis (1) für ein flüssiges Medium (3), insbesondere Blutbeutel, mit einer flexiblen Außenwandung (5) und einer mit dem Behältnis (1) verbundenen Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten. Erfindungsgemäß ist die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten innerhalb der flexiblen Außenwandung (5) angeordnet, wobei Positionierungsmittel (15) vorgesehen sind, welche die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten bei mit dem flüssigen Medium (3) gefüllten Behältnis (1) schwimmend im flüssigen Medium (3) halten, und wobei die Vorrichtung (13) oder die Vorrichtung (13) und die Positionierungsmittel (15) so ausgebildet sind, dass die jeweils verdrängte Masse von flüssigem Medium (3) im Wesentlichen gleich der Masse der Vorrichtung (13) oder der Masse der Vorrichtung (13) und der Positionierungsmittel (15) ist.
Die Erfindung betrifft ein Behältnis (1) für ein flüssiges Medium (3), insbesondere Blutbeutel, mit einer flexiblen Außenwandung (5) und einer mit dem Behältnis (1) verbundenen Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten. Erfindungsgemäß ist die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten innerhalb der flexiblen Außenwandung (5) angeordnet, wobei Positionierungsmittel (15) vorgesehen sind, welche die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten bei mit dem flüssigen Medium (3) gefüllten Behältnis (1) schwimmend im flüssigen Medium (3) halten, und wobei die Vorrichtung (13) oder die Vorrichtung (13) und die Positionierungsmittel (15) so ausgebildet sind, dass die jeweils verdrängte Masse von flüssigem Medium (3) im Wesentlichen gleich der Masse der Vorrichtung (13) oder der Masse der Vorrichtung (13) und der Positionierungsmittel (15) ist.