Refine
Year of publication
Document Type
- Conference Proceeding (299)
- Article (reviewed) (107)
- Article (unreviewed) (32)
- Part of a Book (13)
- Letter to Editor (11)
- Patent (9)
- Contribution to a Periodical (8)
- Book (5)
- Doctoral Thesis (1)
- Report (1)
Conference Type
- Konferenzartikel (208)
- Konferenz-Abstract (61)
- Sonstiges (21)
- Konferenz-Poster (8)
- Konferenzband (1)
Language
- English (486) (remove)
Is part of the Bibliography
- yes (486) (remove)
Keywords
- RoboCup (20)
- Kommunikation (13)
- Eingebettetes System (8)
- Intelligentes Stromnetz (8)
- Brennstoffzelle (7)
- Batterie (6)
- Lithiumbatterie (6)
- Abtragung (5)
- Applikation (5)
- CST (5)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (486) (remove)
Open Access
- Closed Access (191)
- Open Access (173)
- Closed (50)
- Bronze (48)
- Gold (2)
- Diamond (1)
An investigation is underway regarding the usefulness of altazimuth-mounting telescopes' incorporation of laser gyros for pointing and fiber gyros with extremely small random-walk coefficient for telescope inertial stabilization during tracking. A star tracker is expected to help stabilize long-term gyro bias. Gyro and telescope specifications have been derived by means of computer simulations and systems analyses.
A polarization mode dispersion measurement set-up based on a Mach-Zehnder Interferometer was realized. Measurements were carried out on short high-birefringent fibers and on long standard telecommunication single-mode fibers. In order to ensure high accurate results, special emphasis was placed on the evaluation of the interference pattern. The procedure will be described in detail and practical measurement results will be presented.
The prototype of an optical gyro encoder (OGE) has been successfully tested on the NTT telescope in September '93. The OGE consists of a ring laser gyro and a fiber optic gyro with their input axis parallel. The gyro outptu signals are compensated for earth rotation and misalignment and are subsequently integrated to get the angles. An adaptive digital control loop locks the fiber optic gyro to the laser gyro data. Thus the combined output has the precision of the laser gyro and the low noise of the fiber optic gyro. Specifically, the bias stability is better than 2 X 10-3 deg/h, the scale factor accuracy better than 1 ppm, the random walk coefficient better than 5 X 10-4 deg/(root)h and the resolution better than 3 X 10-4 arcsec. The OGE has been mounted in the altitude and in the azimuthy axis of the telescope. The data were compared with the telescope disk encoder data. The test data show that the pointing accuracy is about 1 arcsec and the tracking accuracy 0.1 arcsec over a time of 30 seconds. This accuracy is sufficient for the very large telescope, for instance.
This paper treats the Brillouin backscattering in a single mode optical fiber and its implications on the Brillouin Ring Laser Gyroscope (BRLG). The BRLG consists of a fiber ring cavity in which stimulated Brillouin scattering is induced and provides two resonant counterpropagating backscattered waves. If this cavity is rotating around its axis, the backscattered waves get different resonant frequencies because of the Sagnac effect. The frequency difference is proportional to the rotation rate (Omega) by inducing a frequency offset between the counterpropagating waves. Some reported Brillouin spectra exhibit several peaks, which means that one pump wave provides at least two backscattered waves with distinguishable frequencies. In order to understand this multi-backscattering and to take advantage of it for the BRLG, we present results of a simulation of the Brillouin backscattering in a single mode optical fiber.
This paper treats the interaction between acoustic modes and light (Brillouin scattering) in a single mode optical fibre. Different observed spectra of the Brillouin backscattering in several fibres have been already reported. In order to have a clear idea of the process, we made a simulation to be able to `draw' the theoretical Brillouin spectrum of an optical fibre and to identify the origin of the observed backscattered lines.
First, the model and the computation method used in our simulation are described. Second, the experimentally observed spectra of two real fibres are compared with their computed spectra. Real spectra and simulated spectra are in good agreement.
Our work provides an interesting tool to investigate the changes in the Brillouin spectrum when the input parameters (characteristics of an optical fibre) vary. This should give useful indications to people working on systems which use Brillouin backscattering.
Formal verification (FV) is considered by many to be complicated and to require considerable mathematical knowledge for successful application. We have developed a methodology in which we have added formal verification to the verification process without requiring any knowledge of formal verification languages. We use only finite-state machine notation, which is familiar and intuitive to designers. Another problem associated with formal verification is state-space explosion. If that occurs, no result is returned; our method switches to random simulation after one hour without results, and no effort is lost. We have compared FV against random simulation with respect to development time, and our results indicate that FV is at least as fast as random simulation. FV is superior in terms of verification quality, however, because it is exhaustive.
The flow field-flow fractionation (FIFFF) technique is a promising method for separating and analysing particles and large size macromolecules from a few nanometers to approximately 50 μm. A new fractionation channel is described featuring well defined flow conditions even for low channel heights with convenient assembling and operations features. The application of the new flow field-flow fractionation channel is proved by the analysis of pigments and other small particles of technical interest in the submicrometer range. The experimental results including multimodal size distributions are presented and discussed.
The importance of obtaining simultaneous particle size and concentration values has grown up with continuing discussion of the health effects, of internal combustion engine generated particulate emissions and in particular of Diesel soot emissions. In the present work an aerosol measurement system is described that delivers information about particle size and concentration directly from the undiluted exhaust gas.
Using three laser diodes of different wavelengths which form one parallel light beam, each spectral attenuation is analysed by a single detector and the particle diameter and concentration is evaluated by the use of the Mie theory and shown on-line at a frequency of 1 Hz. The system includes an optical long-path-cell (White principle) with an adjustable path length from 2.5 to 15 m, which allows the analysis within a broad concentration range.
On-line measurements of the particulate emissions in the hot, undiluted exhaust of Diesel engines are presented under stationary and transient engine’s load conditions. Mean particle diameters well below 100 nm are detected for modern Diesel engines. The measured particle concentration corresponds excellently with the traditional gravimetrical measurements of the diluted exhaust. Additionally, measurements of particle emissions (mostly condensed hydricarbons) from a two-stroke engine are presented and discussed.
The bandwidth behavior of graded-index multimode fibers (GI-MMFs) for different launching conditions is investigated to understand and characterize the effect of differential mode delay. In order to reduce the launch-power distribution the near field of a single-mode fiber is used to produce a controlled restricted launch. The baseband response is measured by observing the broadening of a narrow input pulse (time-domain measurement). The paper verifies the degradation in bandwidth due to profile distortion by scanning the spot of the single-mode fiber with a transversal offset from the center of the test sample. In addition, the impact of the launch-power distribution tuned by different spot-size diameters is demonstrated. Measurements were taken on ‘older’ 50-μm and 62.5-μm GI-MMFs as well as on laser-performance-optimized fibers more recently developed.
Bluetooth personal area networks (PANs) share the 2.4 GHz ISM spectrum with the IEEE 802.11b wireless local area networks (WLANs). With the popularity of wireless devices, this ISM spectrum is becoming more and more crowded. As a result of this interference between WLANs and PANs, the performance of each network is decreased. Current research has not significantly covered the degrading impact of an 802.11b interferer on Bluetooth voice transmission. Within this project, simulations were carried out to precisely study the impact of an 802.11b interferer on the performance of Bluetooth voice transmission at different ratio levels of Bluetooth power to WLAN power at the receiver side. Furthermore, the impact of SNR on the Bluetooth voice performance and the benefit of using the SCORT packet type was analysed as well. Based on the results presented, network performance can be evaluated at the desired activity level.
Nowadays the processing power of mobile phones, smartphones and PDAs is increasing as well as the transmission bandwidth. Nevertheless there is still the need to reduce the content and the need of processing the data. We discuss the proposals and solutions for dynamic reduction of the transmitted content. For that, device specific properties are taken into account, as much as for the aim to reduce the need of processing power at the client side to be able to display the 3D (virtual reality) data. Therefore, well known technologies, e.g. data compression are combined with new developed ideas to reach the goal of adaptive content transmission. To achieve a device dependant reduction of processing power the data have to be preprocessed at the server side or the server even has to take over functionality of weak mobile devices.
Experimental and theoretical investigations of the time of equalization of the concentration of an impurity in a rectangular flow‐type chamber have been carried out. It has been shown that the process of equalization of the concentration with time is exponential in character. The characteristic equalization time has been computed using the theory of turbulent diffusion. Theoretical results describe experimental regularities with an accuracy of about 10%. The value of the coefficient of turbulent diffusion for different configurations of flows in the chamber has been obtained from a comparison of experimental and calculated results.
Lattice vibrations and electronic transitions in the rare-earth metals: Praseodymium under pressure
(2004)
Praseodymium was investigated by Raman spectroscopy under pressure. A negative pressure shift of the E2g mode is observed in the dhcp phase, which indicates that the initial structural sequence hcp→Sm−type→dhcp→fcc as a whole in the regular lanthanides is associated with a softening of this mode. The pressure response of the phonon modes, observed in the monoclinic and α-uranium phases, where 4f bonding becomes important, is characteristic for anisotropic bonding properties.
The iSign project started in 2000 as a web-based laboratory setting for students of electrical engineering. In the meantime it has broadened into a heterogeneous learning environment offering learning material, adaptive user settings and access to a simulation tool. All these offerings can be accessed via web and wireless by different clients, such as PCs, PDAs and mobile phones. User adaptive systems offer unique and personalised environment for every learner and therefore are a very important aspect of modern e-learning systems. The iSign project aims to personalise the content structure based on the learner's behaviour, content pattern, policies, and system environment. The second aspect of the recent research and development within this project is the generation of suitable content and presentation for different clients. This generation is based additionally on the user preferences in order to obtain the desirable presentation for a given device. New, valuable features are added to the mobile application, empowering the user not only to control the simulation process with his mobile device but also to input data, view the simulation's output and evaluate the results. Experiences with students have helped to improve functionality and look-and-feel whilst using the iSign system. Our goal is to provide unconstrained, continuous and personalised access to the laboratory settings and learning material everywhere and at anytime with different devices.
This paper explores the potential of an m-learning environment by introducing the concept of mLab, a remote laboratory environment accessible through the use of handheld devices.
We are aiming to enhance the existing e-learning platform and internet-assisted laboratory settings, where students are offered in-depth tutoring, by providing compact tuition and tools for controlling simulations that are made available to learners via handheld devices. In this way, students are empowered by having access totheir simulations from any place and at any time.
The establishment of a software tool chain among requirements management tools, black box test approach tool CTE XL and RTRT is proposed in this paper. The use of Classification Tree Method ensures the reduction in the number of test cases and promises an increased efficiency when testing. The traceability of test cases and requirements is guaranteed by the established software tool chain with well defined interfaces. As the experimental results point out, a better test coverage can be achieved. Future work can be based on automatic generation of init and expected values for testing, requiring no interference from a software quality engineer. In conclusion, the tasks that need to be performed by the software quality engineers is to define the black box test cases using CTM/CTE XL, import the requirements from the requirements management tools, import the XML file to test tool RTRT. By giving the initial and expected values the testing can be performed in a comfortable way.