Refine
Document Type
Conference Type
Has Fulltext
- no (4)
Is part of the Bibliography
- yes (4)
Keywords
- Hörgerät (1)
- bimodal hearing (1)
- cochlear implant (1)
- hearing aid (1)
- interaural stimulation timing (1)
- sound localization (1)
Institute
Open Access
- Open Access (4) (remove)
In users of a cochlear implant (CI) together with a contralateral hearing aid (HA), so-called bimodal listeners, differences in processing latencies between digital HA and CI up to 9 ms constantly superimpose interaural time differences. In the present study, the effect of this device delay mismatch on sound localization accuracy was investigated. For this purpose, localization accuracy in the frontal horizontal plane was measured with the original and minimized device delay mismatch. The reduction was achieved by delaying the CI stimulation according to the delay of the individually worn HA. For this, a portable, programmable, battery-powered delay line based on a ring buffer running on a microcontroller was designed and assembled. After an acclimatization period to the delayed CI stimulation of 1 hr, the nine bimodal study participants showed a highly significant improvement in localization accuracy of 11.6% compared with the everyday situation without the delay line (p < .01). Concluding, delaying CI stimulation to minimize the device delay mismatch seems to be a promising method to increase sound localization accuracy in bimodal listeners.
Das normalhörende auditorische System ist in der Lage, interaurale Zeit- bzw. Phasendifferenzen zur verbesserten Signaldetektion im Störgeräusch zu nutzen. Dieses Phänomen wird häufig als binaurale Entmaskierung bezeichnet und ist sowohl bei einfachen Signalen wie Sinustönen, als auch bei Sprachsignalen im Störgeräusch wirksam. Vorangegangene Studien haben gezeigt, dass binaurale Entmaskierung eingeschränkt auch bei bilateralen CI-Trägern beobachtbar ist (Zirn et al., 2016).
Aktuelle Ergebnisse zeigen, dass die binaurale Entmaskierung sensitiv gegenüber der bilateralen CI-Anpassung ist. So lässt sich der Effekt durch tonotopen Abgleich und Herausstellen eines apikalen Feinstrukturkanals modulieren. Steigerungen der binauralen Entmaskierung um bis zu 1,5 dB sind auf diese Weise gegenüber der konventionellen CI-Anpassung möglich. Allerdings variiert der Einfluss der CI-Anpassung interindividuell erheblich.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPD is highly desirable. In this study, we compared two coding strategies in BiCI users provided with CI systems from MED-EL (Innsbruck, Austria). The CI systems were bilaterally programmed either with the fine structure processing strategy FS4 or with the constant rate strategy high definition continuous interleaved sampling (HDCIS). Familiarization periods between 6 and 12 weeks were considered. The effect of IPD was measured in two types of experiments: (a) IPD detection thresholds with tonal signals addressing mainly one apical interaural electrode pair and (b) with speech in noise in terms of binaural speech intelligibility level differences (BILD) addressing multiple electrodes bilaterally. The results in (a) showed improved IPD detection thresholds with FS4 compared with HDCIS in four out of the seven BiCI users. In contrast, 12 BiCI users in (b) showed similar BILD with FS4 (0.6 ± 1.9 dB) and HDCIS (0.5 ± 2.0 dB). However, no correlation between results in (a) and (b) both obtained with FS4 was found. In conclusion, the degree of IPD sensitivity determined on an apical interaural electrode pair was not an indicator for BILD based on bilateral multielectrode stimulation.